You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 75 No. 1, January 1966 TABLE OF CONTENTS
  Archives
  •  Online Features
  ARTICLES
 This Article
 •References
 •Full text PDF
 • Reply to article
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on HighWire
 •Citing articles on Web of Science (14)
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati Add to Twitter What's this?

Clinical Comparison of Xenon-Arc and Laser Photocoagulation of Retinal Lesions

FRANCIS A. L'ESPERANCE, JR., MD

Arch Ophthalmol. 1966;75(1):61-67.

Since this article does not have an abstract, we have provided the first 150 words of the full text PDF and any section headings.

Photocoagulation of the choroid and retina can be produced by the absorption of light energy from either the xenon-arc or the laser photocoagulator. Both coagulator systems deliver light energy in the visible or infrared region of the spectrum, and the ultimate chorioretinal effect is determined by the total amount of light energy absorbed and converted to heat. The major physical difference between the light and laser systems is the type of radiation developed by each method.

The ruby laser beam delivers light energy at one wavelength (6943 A) in the deep red region of the visible spectrum. The effect on an ocular tissue is determined by the specific tissue absorption for that wavelength only and by the instantaneous (0.0005 seconds) intensity of the beam. The xenonarc high pressure bulb delivers radiation from all portions of the visible and near infrared spectrum (Fig). This broad spectral energy output is presented to . . . [Full Text PDF of this Article]


Author Affiliations

New York

From the Institute of Ophthalmology, Columbia-Presbyterian Medical Center, 635 W 165th St, New York.


Footnotes

Submitted for publication June 2, 1965.

Reprint requests to 1 E 71st St, New York 10021.