You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 106 No. 11, November 1988 TABLE OF CONTENTS
  Archives
  •  Online Features
  CORRESPONDENCE
 This Article
 •Full text PDF
 • Reply to article
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati Add to Twitter What's this?

Intraocular Diathermy for Pupilloplasty During Vitreous Surgery

Jerald A. Bovino, MD; Daniel F. Marcus, MD; Philip T. Nelson, MD
Toledo

Arch Ophthalmol. 1988;106(11):1503-1504.

Since this article does not have an abstract, we have provided the first 150 words of the full text PDF and any section headings.

To the Editor.

—A small pupil can hinder visualization during vitreous surgery. We routinely dilate the pupils of all patients preoperatively, and we use intraocular epinephrine hydrochloride during surgery to maintain dilatation in selected patients. If the pupil does not dilate pharmacologically, in the aphakic patient we use the vitrectomy instrument to perform an iridectomy. We frequently find that an iridectomy performed in this manner results in a cosmetically unacceptable scalloped or irregular pupillary border (Fig 1). In an attempt to produce an anatomically smooth pupillary border, additional cuts with the vitrectomy instrument are often required, and the surgeon may excise more of the iris than originally intended.

We have used the intraocular endodiathermy probe to cauterize the cut irregular edges of the iris after iridectomy (Fig 2). The endodiathermy probe (Medical Instruments Research Associates, Waltham, Mass) is applied at a setting of 0.5 in a sweeping motion along the . . . [Full Text PDF of this Article]