You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 126 No. 11, November 2008 TABLE OF CONTENTS
  Archives
  •  Online Features
  Clinical Sciences
 This Article
 •Full text
 •PDF
 • Reply to article
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Topic Collections
 •Neurology
 •Neuro-ophthalmology
 •Glaucoma
 •Retinal/ Chorioretinal Disorders
 •Alert me on articles by topic

Regional Relationship Between Retinal Nerve Fiber Layer Thickness and Corresponding Visual Field Sensitivity in Glaucomatous Eyes

Akiyasu Kanamori, MD, PhD; Maiko Naka, MD; Azusa Nagai-Kusuhara, MD, PhD; Yuko Yamada, MD, PhD; Makoto Nakamura, MD, PhD; Akira Negi, MD, PhD

Arch Ophthalmol. 2008;126(11):1500-1506.

Objective  To establish the structure-function relationship between peripapillary retinal nerve fiber layer (RNFL) thickness and visual field (VF) test points in standard automated perimetry.

Methods  We included 213 eyes with open-angle glaucoma and VF loss in this cross-sectional study. Correlations between individual VF sensitivity at 52 test points and peripapillary RNFL thickness divided into 16 sectors were calculated. The RNFL thickness was measured by Stratus optical coherence tomography. A new VF cluster map corresponding to RNFL sectors was generated by grouping the VF test points with the highest relation to each RNFL sector.

Results  The VF sensitivity at each test point was significantly correlated with the sectoral RNFL thickness. The highest coefficient of determination (R2) for a superotemporal RNFL sector and VF sensitivity at an inferotemporal test point (9° temporal and 15° inferior from the center) in standard automated perimetry was 0.500 (P < .001). Clustered VF test points most highly related to the RNFL sectors were asymmetrically located between the upper and lower hemifields. A newly developed map revealed significant structure-function relationships.

Conclusions  We describe an association between VF sensitivity at test points and sectoral RNFL thickness. Nine clustered VF test points corresponding to 9 RNFL regions were demonstrated from the structure-function relationships.


Author Affiliations: Division of Ophthalmology, Department of Surgery, Kobe University Graduate School of Medicine, Kobe, Japan.







HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 