You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 126 No. 5, May 2008 TABLE OF CONTENTS
  Archives
  •  Online Features
  Clinical Sciences
 This Article
 •Abstract
 •PDF
 • Reply to article
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on HighWire
 •Citing articles on Web of Science (3)
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Topic Collections
 •Ophthalmology, Other
 •Alert me on articles by topic
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati Add to Twitter What's this?

Dynamic Distribution of Artificial Tears on the Ocular Surface

Jianhua Wang, MD, PhD; Peter Simmons, PhD; James Aquavella, MD; Joseph Vehige, OD; Jayachandra Palakuru, MD; Suk Chung, BS; Changyong Feng, PhD

Arch Ophthalmol. 2008;126(5):619-625.

ABSTRACT

Objective  To study the effects of artificial tear viscosity on tear film thickness, upper and lower tear menisci, and tear volume using optical coherence tomography.

Methods  The central tear film and tear menisci before and immediately after the instillation of different artificial tears were imaged in 40 eyes of 20 healthy individuals. Carboxymethylcellulose sodium, 1.0% (viscosity, 70 cP), propylene glycol, 0.3%, and polyethylene glycol, 0.4% (10 cP), carboxymethylcellulose, 0.5% (3 cP), and isotonic sodium chloride solution (1 cP) were tested on 2 consecutive days. All measurements, including tear film thickness, the height, radius, and area of the tear meniscus, and the estimated tear volume, were obtained at 0, 5, 20, 40, and 60 minutes after instillation.

Results  At instillation, all artificial tears and isotonic sodium chloride solution caused an increase in all tear variables (P < .001). Tear film thickness remained significantly elevated for all drops at 5 minutes (P < .001) and returned to baseline at 20 minutes. Other variables returned to baseline at 5 minutes. Comparing the different drops, tear film thickness and lower meniscus variables at instillation were increased with the more viscous drops (P < .05).

Conclusion  Optical coherence tomography demonstrated that all tear preparations, including isotonic sodium chloride solution, increased tear film thickness for at least 5 minutes and other variables immediately afterinstillation.



INTRODUCTION
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Author information
 •References

Normal tear volume is estimated to be on the order of 8.5 µL, in which 4.5 µL is in the cul-de-sac and approximately 2.9 µL and 1.1 µL are in the tear menisci and preocular tear film, respectively.1 Dynamically balanced distribution of the tears may be critical in formulating a healthy and long-lasting tear film, which protects the ocular surface during eye opening. As determined by invasive methods, the interaction of the tear menisci and cul-de-sac has been reported to determine the stability of the tear film,2 tear volume,3 and tear turnover.4 Tear volume has also been studied by measuring the lower tear meniscus with videomeniscometry that uses a bright light shining on the eye5-6 or videophotography with the aid of fluorescein.7-8 Noninvasive measurements of the inferior meniscus have been taken using a commercially available optical coherence tomography (OCT) instrument.9 Each of these studies attempted to characterize the entire tear film system based on the changes in a single compartment or by snapshot measurements.

Anterior segment OCT provides highly repeatable images suitable for analyzing tear dynamics10-11 and quantifying the effect of blinking.12 Because of its superior image-capturing ability and its noninvasive nature, it has great potential as a tool to analyze the tear dynamics of artificial tears. We tested this hypothesis by quantifying the effect of the viscosity of commercial artificial tears on the central tear film, the upper and lower tear menisci, and the tear volume using serial OCT examinations.


METHODS
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Author information
 •References

SAMPLE POPULATION

This study was approved by the research review board of the University of Rochester. Informed consent was obtained from each study participant, and each was treated in accordance with the tenets of the Declaration of Helsinki. Thirteen women and 7 men (mean [SD] age, 40.5 [14.1] years) in good health and with no history of contact lens wear or any current ocular or systemic diseases participated in this prospective study.

ANTERIOR SEGMENT OCT

A real-time corneal OCT, custom developed with the same configurations as described previously,10-13 was used to obtain an image of the eye. Briefly, the OCT light source was 1310 nm with a bandwidth of 60 nm. A telecentric optical probe was mounted with a standard slitlamp. A maximum 15-mm scanning width at up to 8 frames per second was achieved. A digital video system was incorporated into the viewing system of the slitlamp to facilitate positioning the OCT scan location on the cornea. We ensured that the sagittal OCT measurements passed through the corneal apex by observing the specular reflex. The OCT images were recorded continuously, whereas the specular reflex from the central cornea was observed through the video system. The study participants looked at an external target (a red dot) and were exposed only to ambient room light because the OCT light was not visible. The entire scanned image was 960 pixels (12.0 mm) wide and 384 pixels (2.0 mm) deep in air. The interval between 2 image pixels was 3.7 µm in the axial direction, assuming a group corneal refractive index of 1.39 with 1310 nm of light.14 The lateral interval between 2 image pixels was 12.5 µm. The high repeatability in measurements of tear film thickness (TFT) and tear meniscus variables has been previously documented.11 In brief, the repeatability for measuring corneal thickness using our custom-built OCT was approximately 2 µm.

OUTCOME MEASURES

Five outcome measures were obtained at each visit. These measures included central TFT, 3 tear meniscus variables around the upper and lower eyelids, and total estimated tear volume. The tear meniscus variables included the upper tear meniscus radius (UTMR), upper tear meniscus height (UTMH), upper tear meniscus cross-sectional area (UTMA), lower tear meniscus radius (LTMR), lower tear meniscus height (LTMH), and lower tear meniscus cross-sectional area (LTMA). The 8 images, corresponding to 1 second of time, immediately after a full blink, were used to yield these variables. Data from 2 interblink intervals at each time were averaged. Total tear volume was calculated as detailed later.

VISCOSITY OF THE DROPS

We tested 3 different artificial tears and an isotonic sodium chloride solution control (Table). These drops included carboxymethylcellulose sodium, 1.0% (70 cP; Refresh Liquigel; Allergan, Irvine, California); propylene glycol, 0.3%, and polyethylene glycol, 0.4% (10 cP; Systane; Alcon, Fort Worth, Texas); carboxymethylcellulose, 0.5% (3 cP; Refresh Tears; Allergan); and isotonic sodium chloride solution (1 cP).


View this table:
[in this window]
[in a new window]
[as a PowerPoint slide]
 
Table. Tested Drops and Study Visits


DROP TEST PROTOCOL

A randomization table was used to assign the drop sequence and resulted in an initial test pair of carboxymethylcellulose, 1.0%, and isotonic sodium chloride solution; and a second pair of carboxymethylcellulose, 0.5%, and propylene glycol, 0.3%, and polyethylene glycol, 0.4%. The pair of solutions was tested in separate eyes (Table) on 2 consecutive days (days 1 and 2) at the same time of day. Later, the same 2 pairs were again tested but in the reverse order. For each solution, the first drop was instilled into the right eye, and then 30 minutes later the pairwise drop was instilled into the left eye. These imaging sessions were staggered between eyes to facilitate the imaging on both eyes. Each drop in each eye was followed up for 60 minutes. It took approximately 1.5 hours to complete each visit.

STUDY PROCEDURE

To establish baseline variables before any drops were added, a vertical 12-mm OCT scan was performed across the central cornea (apex) while the study participant blinked normally. The OCT imaging was repeated immediately and at 5, 20, 40, and 60 minutes after instillation of 35 µL of the designated artificial tear or isotonic sodium chloride solution control by a pipette. These imaging sessions were staggered between eyes to facilitate the imaging of both eyes. During the break between OCT imaging, the participant was asked to sit in the laboratory while an audio reminder set to blink at 10 blinks per minute was played to facilitate as much as possible the participant's control of the blink rate. After the 60-minute follow-up with the 2 less viscous solutions (carboxymethylcellulose, 0.5%, and isotonic sodium chloride solution), 1 drop of gel (GenTeal; Novartis Pharmaceuticals, East Hanover, New Jersey) was instilled into the eye, followed by OCT imaging. This procedure highlighted the interface between the cornea and the tears and facilitated the measurement of true corneal thickness (Figure 1) for the calculation of TFT. With the more viscous artificial tears (carboxymethylcellulose, 1.0%, and propylene glycol, 0.3%, and polyethylene glycol, 0.4%), there was no need to use the gel because we were able to obtain true corneal thickness immediately after the instillation of these drops (Figure 2).


Figure 1
View larger version (119K):
[in this window]
[in a new window]
[as a PowerPoint slide]
 
Figure 1. Image processing of tear film thickness (TFT) and tear meniscus height. The optical coherence tomography (OCT) image was taken immediately after instillation of carboxymethylcellulose sodium, 1.0%, artificial tears. Using custom software, the OCT image was processed to yield the measurements of central TFT and tear meniscus variables of height, radius, and cross-sectional area. Touch points (pink dots) between 2 of the elements (eyelid, cornea, and tear meniscus) and a middle point (green dot) of the front edge of the tear meniscus were marked. After that, the software processed the image to yield the results. The 3-point method was used to fit a circle to yield the tear meniscus radius. The tear meniscus heights around both upper (A) and lower (C) lids were obtained by the analysis of vertical distances (green lines). The central TFT (B) was obtained by processing the central 21 longitudinal scans from the endothelium to epithelium side, after the unusable 30 axial scans with specular reflex were removed.



Figure 2
View larger version (179K):
[in this window]
[in a new window]
[as a PowerPoint slide]
 
Figure 2. Optical coherence tomography (OCT) images at baseline and immediately after instillation of artificial tears and isotonic sodium chloride solution. A vertical 12-mm scan was performed at baseline (A) and immediately after instillation of 35 µL of drops (B-E). The cornea (CO), epithelium (marked by green asterisk), upper eyelids (UL), lower eyelids (LL), upper tear menisci (UTM), and lower tear menisci (LTM) were visualized. With carboxymethylcellulose sodium, 1.0%, and propylene glycol, 0.3%, and polyethylene glycol, 0.4%, the tear film is marked by the red asterisk. Greater tear menisci were present immediately after instillation of all 4 solutions (B-E). The larger increases of TFT (red asterisk) were with carboxymethylcellulose, 1.0% (B) and propylene glycol, 0.3%, and polyethylene glycol, 0.4% (C). Tear film thicknesses in panels A, D, and E were calculated as detailed in the "Image Processing" subsection of the "Methods" section.


IMAGE PROCESSING

Custom software was used to process the OCT images to obtain these results. To avoid the distortion due to the central specular reflex of each image, the central 30 pixels (0.39-mm width) were removed. After that, a reflectivity profile (Figure 1D) was generated from the central 21 axial scans of 8 consecutive images immediately after blinking. The combined thickness, including the cornea and TFT, was defined as the distance between the first and last peaks, and true corneal thickness without the tear film was defined as the distance between the first and last second peaks. The TFT was determined indirectly by subtracting the corneal thickness obtained after the instillation of carboxymethylcellulose, 1.0%, and propylene glycol, 0.3%, and polyethylene glycol, 0.4%, or the gel after instillation of carboxymethylcellulose, 0.5%, and isotonic sodium chloride solution from the combined thickness of the cornea and the tear film measured at all checkpoints.

Immediately after blinking, the first clear image (Figure 1) among the first 8 images that showed both the upper and lower tear menisci was processed to obtain the tear meniscus variables. The OCT image was processed to yield the measurements of tear meniscus variables of height, radius, and cross-sectional area. Two specific points of the eyelid, cornea, or tear meniscus and a middle point of the front edge of the tear meniscus were marked. After that, the software processed the image to yield the results. The 3-point method was used to fit a circle to yield the tear meniscus radius. The tear meniscus heights around both upper and lower lid margins were obtained by the analysis of vertical distances from the images.

TEAR VOLUME ESTIMATION

Total tear volume was estimated from upper and lower tear menisci and TFT based on some assumptions. The tear film volume was calculated by multiplying the TFT times 250 mm2, the average exposed surface area. Because the tear meniscus height seems not to be uniform across the eyelid, with the largest value in the center, a factor of 3/4 was used to calculate the tear volume in the tear menisci according to a previous study.15 An eyelid length of 25 mm was used as a constant to complete the calculation of total tear volume on the ocular surface. The complete equation was as follows: Total Tear Volume on Ocular Surface = (250 mm2 x TFT) + (3/4 x 25 mm x UTMA) + (3/4 x 25 mm x LTMA)

STATISTICAL ANALYSIS

Data analysis was conducted using a statistical analysis software package (Statistica; StatSoft Inc, Tulsa, Oklahoma). Repeated-measures analysis of variance was used for overall effects, and post hoc paired t tests were used to determine any pairwise differences (P < .05).


RESULTS
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Author information
 •References

Between the 2 successive measurements during the study period, no significant differences were found in any of the measured variables and estimated tear volume with all 4 drops (repeated-measures analysis of variance, P = .58). Immediately after the instillation of artificial tears and isotonic sodium chloride solution, all variables increased significantly (post hoc tests, P < .001; Figure 3 and Figure 4). After that, the values recovered to baseline with no significant differences after 20 minutes (Figure 3A-H).


Figure 3
View larger version (77K):
[in this window]
[in a new window]
[as a PowerPoint slide]
 
Figure 3. Measured variables of tear distributions over time with 3 artificial tears and the control. Mean results from successive measurements of both eyes were plotted in panels A through H. A, Significant increases of tear film thickness (TFT) occurred immediately after instillation and remained at 5 minutes (P < .001). Carboxymethylcellulose sodium, 1.0%, and propylene glycol, 0.3%, and polyethylene glycol, 0.4%, induced significantly greater increases of TFT thancarboxymethylcellulose, 0.5%, and isotonic sodium chloride solution. At 5 minutes, no differences were found among the drops, although the TFT remained elevated compared with baseline (P < .001). B, Immediately after instillation, estimated tear volume increased significantly with all drops (P < .001), with the highest increase by carboxymethylcellulose, 1.0%. At 5 minutes, the increases by carboxymethylcellulose, 1.0%, and propylene glycol, 0.3%, and polyethylene glycol, 0.4%, were significantly different from baseline. C, For the upper tear meniscus radius, no differences were found among drops over time. D, For the lower tear meniscus radius, carboxymethylcellulose, 1.0%, induced significantly greater increases (P < .001) immediately after instillation compared with the other solutions. At 5 minutes and afterward, no differences were found among drops. E, For the upper tear meniscus height, propylene glycol, 0.3%, and polyethylene glycol, 0.4%, induced a greater increase immediately after instillation than carboxymethylcellulose, 1.0% (P < .001). At 5 minutes and afterward, no differences were found among drops. F, For the lower tear meniscus height, carboxymethylcellulose, 1.0%, induced significantly greater increases (P < .001) immediately after instillation and at 5 minutes compared with the other solutions. After that, no differences were found among drops. G, For the upper tear meniscus cross-sectional area, propylene glycol, 0.3%, and polyethylene glycol, 0.4%, induced a greater increase immediately after instillation than carboxymethylcellulose, 1.0% (P < .001). At 5 minutes and afterward, no differences were found among drops. H, For the lower tear meniscus cross-sectional area,carboxymethylcellulose, 1.0%, induced a significantly greater increase (P < .001) immediately after instillation compared with others. At 5 minutes and afterward, no differences were found among drops. Vertical bars denote 95% confidence intervals.



Figure 4
View larger version (51K):
[in this window]
[in a new window]
[as a PowerPoint slide]
 
Figure 4. Correlations between measured variables and viscosities of artificial tears and the control solution. Results are the means from both eyes at successive measurements, and the logarithmic regression equations are presented in each plot. Immediately after instillation, the central tear film thickness and tear volume (A), lower tear meniscus radius (B), lower tear meniscus height (C), and lower tear meniscus cross-sectional area (D) were strongly correlated with the viscosity of tested artificial tears. However, variables of the upper tear meniscus (B-D) were not well correlated with viscosity. Note the different scales in each plot from A through D. Vertical bars denote 95% confidence intervals.


Among the drops studied, carboxymethylcellulose, 1.0%, and propylene glycol, 0.3%, and polyethylene glycol, 0.4%, induced significantly higher TFT than carboxymethylcellulose, 0.5%, and isotonic sodium chloride solution immediately after instillation (post hoc tests, P > .05). At 5 minutes, no significant differences were found in TFT among drops (post hoc tests, P > .05), although the increases due to all drops were significant compared with baseline (Figure 3A). Immediately after instillation, carboxymethylcellulose, 1.0%, induced a significantly greater increase of estimated tear volume compared with others. At 5 minutes, no significant differences among drops were found (post hoc tests, P > .05), whereas carboxymethylcellulose, 1.0%, and propylene glycol, 0.3%, and polyethylene glycol, 0.4%, remained significantly higher than baseline (Figure 3B).

No differences were found in UTMR among drops over time (Figure 3C). Carboxymethylcellulose, 1.0%, induced significantly greater LTMR immediately after instillation compared with others, and by 5 minutes and afterward, no differences were seen among the drops (Figure 3D). Propylene glycol, 0.3%, and polyethylene glycol, 0.4%, induced a greater increase in UTMH immediately after instillation than the others (P < .001), and at 5 minutes and afterward, no differences were seen among drops (Figure 3E). Carboxymethylcellulose, 1.0%, induced significantly greater LTMH immediately after instillation compared with others and at 5 minutes compared with carboxymethylcellulose, 0.5%, and isotonic sodium chloride solution (Figure 3F). Propylene glycol, 0.3%, and polyethylene glycol, 0.4%, induced greater UTMA immediately after instillation than carboxymethylcellulose, 1.0% (P < .001), but by 5 minutes and afterward, no significant differences were found (Figure 3F). Carboxymethylcellulose, 1.0%, induced significantly greater LTMA immediately after instillation compared with others (Figure 3H).

Immediately after instillation of the 4 solutions, TFT (Figure 4A), tear volume (Figure 4A), LTMR (Figure 4B), LTMH (Figure 4C), and LTMA (Figure 4D) strongly correlated with the viscosities of these artificial tears. However, upper tear meniscus variables were not correlated with tear viscosities (Figure 4B-D). Immediately after instillation, the lower tear meniscus variables correlated with viscosity, with carboxymethylcellulose, 1.0%, greater than propylene glycol, 0.3%, and polyethylene glycol, 0.4%, which was greater than carboxymethylcellulose, 0.5%, which was greater than isotonic sodium chloride solution. For the upper tear meniscus variables, the correlation with viscosity was propylene glycol, 0.3%, and polyethylene glycol, 0.4%, greater than carboxymethylcellulose, 1.0%, which was greater thancarboxymethylcellulose, 0.5%, which was equal to isotonic sodium chloride solution (Figure 4B-D). The dominant component of the estimated total tear volume of the ocular surface was the lower meniscus (Figure 2 and Figure 3).


COMMENT
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Author information
 •References

The present study reports on the development and use of real-time anterior segment OCT to evaluate the dynamics of the tear-film cycle, particularly in relation to the effect of different artificial tear formulas. A custom OCT device was used to capture cross-sectional images of the entire interpalpebral ocular surface at approximately 8 times per second. To our knowledge, this is the first time that multiple variables indicating tear distribution and dynamics after adding artificial tears were obtained simultaneously. This study, therefore, provides baseline variables for further modeling the tear system. Real-time scanning and recording of the OCT as used in this study enable continuous imaging of the tears and dynamic distribution on the ocular surface. In particular, blinks can be tracked and the conditions before and after the blink can be studied. Because this system uses a nonvisible scan light and no materials other than the test fluid are added to the eye, it minimizes reflex tearing and the disturbance of the tear system. A wide scan with a telocentric optical design ensures simultaneous imaging of both upper and lower tear menisci and of the tear film itself. This enables us to better understand the tear system. For instance, from the captured images after instillation of carboxymethylcellulose, 1.0% (Figure 2), the lower tear meniscus seems to extend considerably farther forward across the mucocutaneous junction. This observation might change the conventional view about the role of the mucocutaneous junction, which has been thought to be the limit of the lower tear meniscus.

The repeatability of OCT imaging in the measurement of corneal thickness16 and tear dynamics10-12 has previously been reported. With approximately 2 µm of repeatability in the measurement of total thickness of the cornea and tear film,11 the OCT used in this study is able to detect the change of TFT after the instillation of artificial drops10 and the effect of blinking on the tear dyanmics.12 In this study, the differences among different viscous drops were successfully demonstrated. For the tear meniscus, repeatability varies among days, blinks, and blink patterns.11-12 Overall, the device has proved to reliably detect changes in tear meniscus variables after interventions such as delayed blinking12 and the instillation of artificial tears, as shown in the present study.

The dynamic distribution of artificial tears was investigated in this study, and the results showed a significant increase of the measured variables with all 4 drops tested. The TFT, tear volume, and lower tear meniscus variables immediately after instillation varied among drops, but the values were generally proportional to artificial tear viscosity. This finding confirms observations by Zaki et al17 and Wilson,18 who found that increasing the viscosity of instilled fluid slowed the fluid clearance. One of the findings of the present study was that changes in central TFT and lower tear meniscus dimensions were correlated with the viscosity of the artificial tear, but the dimensions of the upper tear meniscus were not. These results indicate that other factors, such as specific gravity or wetting characteristics of the artificial tear, may be more important in determining the fluid held along the upper lid. The upper lid has a tendency to lose fluid owing to gravity and travel distance, and it also moves more rapidly than the lower lid during blinking.

Hydraulic connectivity between the upper and lower menisci might also explain our results. In this model, the 2 menisci are hypothesized to be connected via the lateral canthus with free flow between them. If this is the case, then the relationship between the upper and lower radii can be deduced as follows. By approximating the shapes of the upper and lower menisci as cylinders, the pressures relative to atmospheric pressure of the upper (PUTM) and lower (PLTM) menisci are given by the following:

PUTM = – T/UTMRPLTM = – T/LTMR

where T is the surface tension and UTMR and LTMR are the radii of the upper and lower menisci, respectively. If there is free flow between the 2 menisci, the pressure difference between them should be given by the following:

PLTM – PUTM = {Delta}h x d x g

where {Delta}h is the height difference between upper and lower menisci, d is the density of the tear film, and g is the acceleration due to gravity. Combining these 3 equations yields the following:

1/UTMR = 1/LTMR + {Delta}h x d x g/T

Immediately after instillation of carboxymethylcellulose, 1.0% (Figure 3C and D), the radius of the LTMR is approximately 0.3 cm, and the surface tension is approximately 45 dynes/cm,19 the height difference is 0.8 cm (Figure 3E and F), the density is 1 g/cm3, and the acceleration is 981 cm2/s. Solution of the final equation gives a UTMR of 0.0481 cm (481 µm), which is close to the observed value in Figure 3C. Furthermore, if the LTMR is reduced to half of that value, 0.15 cm (corresponding roughly to the value observed for propylene glycol, 0.3%, and polyethylene glycol, 0.4%), the predicted reduction in the UTMR is relatively small (eg, 481-415 µm). Thus, this model seems to explain why relatively large variations in the LTMR cause relatively little variation in the UTMR.

This study has some limitations and possible measurement errors. No midviscosity was selected for the quantitation of the effect on dynamic tear distribution. Additional studies on this might be warranted. Another limitation could be that the true corneal thickness for the calculation of tear film was obtained at different times with different tested drops. With less viscous drops, the true corneal thickness was obtained after the 60-minute follow-up. With the more viscous drops, it was obtained immediately after the instillation of the tested drops. This might induce possible measurement errors because corneal thickness might alter during the study period. From the data shown in Figure 3A, the alteration of the corneal thickness during such a short period seems to be little because the TFTs at 60 minutes were similar with all 4 drops. Furthermore, the values were almost identical to those at baseline. This possible error could be simply eliminated by applying the gel to all tested drops. Other factors that contribute to possible errors in this method have been discussed previously.10-11 Reflex tearing in the opposite eye might be induced during instillation of the artificial tears in the test eye. The tearing effect can be discounted because each drop was tested twice, once as the first drop and again as the second drop on each study participant.

In summary, OCT is a promising method for studying the tear system and the effect of viscosity of artificial tears. Immediately after drop instillation, tear viscosity was correlated with the TFT, the lower tear meniscus, and the estimated tear volume. However, no effect was seen 20 minutes after drop instillation.


AUTHOR INFORMATION
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Author information
 •References

Correspondence: Jianhua Wang, MD, PhD, Bascom Palmer Eye Institute, University of Miami, Miller School of Medicine, 1638 NW 10th Ave, McKnight Bldg, Room 506, Miami, FL 33136 (jwang3{at}med.miami.edu).

Submitted for Publication: October 3, 2006; final revision received August 20, 2007; accepted August 20, 2007.

Author Contributions: Dr Wang had full access to all the data in the study and takes responsibility for the integrity of the data and the accuracy of the data analysis.

Financial Disclosure: None reported.

Funding/Support: This study was supported by research grants from Allergan and National Eye Institute core center grant P30 EY014801 to Bascom Palmer Eye Institute and Research to Prevent Blindness through the Department of Ophthalmology.

Additional Contributions: Britt Bromberg, PhD, of Xenofile Editing, provided editing services for the manuscript.

Author Affiliations: Bascom Palmer Eye Institute, University of Miami, Miami, Florida (Drs Wang and Palakuru); Allergan Inc, Irvine, California (Drs Simmons and Vehige); and Departments of Ophthalmology (Drs Wang, Aquavella, and Palakuru and Mr Chung) and Biostatistics and Computational Biology (Dr Feng), University of Rochester, Rochester, New York.


REFERENCES
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Author information
 •References

1. Mishima S, Gasset A, Klyce SD Jr, Baum JL. Determination of tear volume and tear flow. Invest Ophthalmol. 1966;5(3):264-276. FREE FULL TEXT
2. Golding TR, Bruce AS, Mainstone JC. Relationship between tear-meniscus parameters and tear-film breakup. Cornea. 1997;16(6):649-661. ISI | PUBMED
3. Cedarstaff TH, Tomlinson A. Human tear volume, quality and evaporation: a comparison of Schirmer, tear break-up time and resistance hygrometry techniques. Ophthalmic Physiol Opt. 1983;3(3):239-245. ISI | PUBMED
4. Occhipinti JR, Mosier M, LaMotte J, Monji G. Fluorophotometric measurement of human tear turnover rate. Curr Eye Res. 1988;7(10):995-1000. ISI | PUBMED
5. Yokoi N, Komuro A. Non-invasive methods of assessing the tear film. Exp Eye Res. 2004;78(3):399-407. FULL TEXT | ISI | PUBMED
6. Oguz H, Yokoi N, Kinoshita S. The height and radius of the tear meniscus and methods for examining these parameters. Cornea. 2000;19(4):497-500. FULL TEXT | ISI | PUBMED
7. Mainstone JC, Bruce AS, Golding TR. Tear meniscus measurement in the diagnosis of dry eye. Curr Eye Res. 1996;15(6):653-661. ISI | PUBMED
8. Doughty MJ, Laiquzzaman M, Button NF. Video-assessment of tear meniscus height in elderly Caucasians and its relationship to the exposed ocular surface. Curr Eye Res. 2001;22(6):420-426. FULL TEXT | ISI | PUBMED
9. Johnson ME, Murphy PJ. The agreement and repeatability of tear meniscus height measurement methods. Optom Vis Sci. 2005;82(12):1030-1037. FULL TEXT | ISI | PUBMED
10. Wang J, Aquavella J, Palakuru J, Chung S. Repeated measurements of dynamic tear distribution on the ocular surface after instillation of artificial tears. Invest Ophthalmol Vis Sci. 2006;47(8):3325-3329. FREE FULL TEXT
11. Wang J, Aquavella J, Palakuru J, Chung S, Feng C. Relationships between central tear film thickness and tear menisci of the upper and lower eyelids. Invest Ophthalmol Vis Sci. 2006;47(10):4349-4355. FREE FULL TEXT
12. Palakuru JR, Wang J, Aquavella JV. Effect of blinking on tear dynamics. Invest Ophthalmol Vis Sci. 2007;48(7):3032-3037. FREE FULL TEXT
13. Wang J, Thomas J, Cox I, Rollins A. Noncontact measurements of central corneal epithelial and flap thickness after laser in situ keratomileusis. Invest Ophthalmol Vis Sci. 2004;45(6):1812-1816. FREE FULL TEXT
14. Lin RC, Shure MA, Rollins AM, Izatt JA, Huang D. Group index of the human cornea at 1.3-µm wavelength obtained in vitro by optical coherence domain reflectometry. Opt Lett. 2004;29(1):83-85. FULL TEXT | ISI | PUBMED
15. Jones LW, Rahman S, Leech R, Simpson T, Fonn D. Determination of inferior tear meniscus height and inferior tear meniscus volume using optical coherence tomography [ARVO e-abstract 144]. Invest Ophthalmol Vis Sci. 2004;45(5):1600.
16. Muscat S, Parks S, Kemp E, Keating D. Repeatability and reproducibility of macular thickness measurements with the Humphrey OCT system. Invest Ophthalmol Vis Sci. 2002;43(2):490-495. FREE FULL TEXT
17. Zaki I, Fitzgerald P, Hardy JG, Wilson CG. A comparison of the effect of viscosity on the precorneal residence of solutions in rabbit and man. J Pharm Pharmacol. 1986;38(6):463-466. ISI | PUBMED
18. Wilson CG. Topical drug delivery in the eye. Exp Eye Res. 2004;78(3):737-743. FULL TEXT | ISI | PUBMED
19. Wong H, Fatt I, Radke C. Deposition and thinning of the human tear film. J Colloid Interface Sci. 1996;184(1):44-51. FULL TEXT | ISI | PUBMED


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter     What's this?

THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

Lower Volumes of Tear Menisci in Contact Lens Wearers with Dry Eye Symptoms
Chen et al.
IOVS 2009;50:3159-3163.
ABSTRACT | FULL TEXT  

Upper and Lower Tear Menisci in the Diagnosis of Dry Eye
Shen et al.