You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 122 No. 5, May 2004 TABLE OF CONTENTS
  Archives
  •  Online Features
  Clinical Sciences
 This Article
 •Abstract
 •PDF
 • Reply to article
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on HighWire
 •Citing articles on Web of Science (30)
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Topic Collections
 •Glaucoma
 •Ocular Imaging
 •Articles for Residents
 •Alert me on articles by topic
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati Add to Twitter What's this?

Comparison of Scanning Laser Polarimetry Using Variable Corneal Compensation and Retinal Nerve Fiber Layer Photography for Detection of Glaucoma

Felipe A. Medeiros, MD; Linda M. Zangwill, PhD; Christopher Bowd, PhD; Kourosh Mohammadi, BA; Robert N. Weinreb, MD

Arch Ophthalmol. 2004;122:698-704.

ABSTRACT

Objective  To compare retinal nerve fiber layer (RNFL) measurements obtained with scanning laser polarimetry (SLP) using variable corneal polarization compensation with standard red-free photography for detection of RNFL damage in glaucoma.

Methods  This observational, cross-sectional study included 1 eye of each of 42 patients with open-angle glaucoma, 32 patients suspected of having glaucoma, and 40 healthy subjects. The RNFL measurements using SLP with variable corneal compensation were obtained within 3 months of red-free photographs. Two independent observers graded RNFL photographs using a standardized protocol. Superior and inferior hemiretinas were scored separately, and a global score was obtained by averaging scores from each hemiretina.

Main Outcome Measures  The RNFL photography scores were compared with RNFL thickness measurements obtained with SLP. The receiver operating characteristic (ROC) curves were constructed to assess the abilities of the different methods to differentiate glaucoma patients from healthy subjects.

Results  The RNFL thickness decreased with increased RNFL damage as assessed by photographs in both hemiretinas (R2 = 15%-47%). The area under the ROC curve for the best SLP parameter, Nerve Fiber Indicator, was significantly greater than the area under the ROC curve for the global RNFL photography score (0.91 vs 0.84, P = .03).

Conclusions  A moderate correlation was found between RNFL thickness measurements obtained with SLP and RNFL scores from red-free photographs. Compared with semiquantitative RNFL photography scores, the best SLP parameter had a higher diagnostic accuracy to separate glaucoma patients from healthy subjects.



INTRODUCTION
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Author information
 •References

Retinal nerve fiber layer (RNFL) abnormalities have been shown to precede the development of visual field defects in glaucoma patients.1-3 Although RNFL photographs have been established as a standard method for detection of RNFL defects, the qualitative and subjective nature of this assessment, as well as the requirement for maximal pupillary dilation and optimal media clarity, limits its widespread applicability.4

Scanning laser polarimetry (SLP) is a diagnostic tool developed to quantitatively measure the thickness of the peripapillary RNFL. It is based on the principle that polarized light passing through the birefringent RNFL undergoes a measurable phase shift, known as retardation, which is linearly related to histologically measured RNFL tissue thickness.5 Although differences in retardation between healthy and glaucomatous eyes have been previously described,6-11 earlier studies12-13 evaluating RNFL photographs and SLP in glaucoma showed only modest associations between these 2 methods.

A significant source of error in previous studies evaluating the SLP technology was most likely introduced by the erroneous compensation of anterior segment birefringence.14-19 The RNFL is not the only birefringent structure in the eye. The cornea and Henle fiber layer of the macula, and to a lesser extent the lens, also are birefringent.20-23 To address anterior segment birefringence, the first commercial SLP had a fixed corneal compensator. The compensator was calibrated based on the assumption that all individuals had a slow axis of corneal birefringence 15° nasally downward with a magnitude of retardance of 60 nm. However, there is a wide variation in both the axis and the magnitude of corneal birefringence in healthy and glaucomatous individuals.17-18,22, 24 An improvement of the SLP technology consisting of the variable compensation of anterior segment birefringence has been recently described.25 Weinreb et al26 showed that SLP with variable compensation of the axis and magnitude of corneal birefringence results in improvement of the sensitivity and specificity of several parameters to discriminate between healthy and glaucomatous eyes. Further, monkey studies27-28 have suggested that RNFL measures obtained with SLP using variable corneal compensation (VCC) better reflect the RNFL qualitative appearance than measures obtained using SLP with fixed corneal compensation.

To determine the clinical validity of any new technology, it is important to compare it with previously established diagnostic techniques with proven clinical utility. Hence, the purpose of this study was to compare RNFL measurements obtained with SLP using VCC to standard red-free photography for detection of RNFL damage in glaucoma.


METHODS
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Author information
 •References

This observational, cross-sectional study included 114 eyes of 114 patients. Forty-two patients had open-angle glaucoma, 32 patients were suspected of having glaucoma, and 40 were healthy. Mean ± SD age of glaucoma patients, patients suspected of having glaucoma, and healthy individuals was 67 ± 11 years, 61 ± 12 years, and 65 ± 11 years, respectively (P = .06, analysis of variance). All patients were evaluated at the Hamilton Glaucoma Center, University of California, San Diego, and retrospectively selected from our research database. These patients were included in a prospective, longitudinal study designed to evaluate optic nerve structure and visual function in glaucoma. All patients who met the inclusion criteria described were enrolled in the current study. Informed consent was obtained from all participants. The University of California, San Diego, Human Subjects Committee approved all protocols, and the methods described adhered to the tenets of the Declaration of Helsinki.

Each subject underwent a comprehensive ophthalmologic examination, including review of medical history, best corrected visual acuity, slitlamp biomicroscopy, intraocular pressure (IOP) measurement using Goldmann applanation tonometry, gonioscopy, dilated funduscopic examination using a 78-diopter (D) lens, stereoscopic optic disc photography, and automated perimetry using 24-2 full-threshold standard automated perimetry or Swedish Interactive Threshold Algorithm (Zeiss-Humphrey field analyzer, Zeiss-Humphrey, Dublin, Calif). To be included, subjects had to have best corrected visual acuity of 20/40 or better, spherical refraction within ±5.0 D, cylinder correction within ±3.0 D, and open angles on gonioscopy. Eyes with coexisting retinal disease, uveitis, or nonglaucomatous optic neuropathy were excluded from this investigation. One eye of each patient was randomly selected for inclusion in the study.

The eyes of the healthy controls had IOPs of 22 mm Hg or less, with no history of increased IOP and a normal visual field result. Normal visual field was defined as a mean deviation (MD) and pattern standard deviation (PSD) within 95% confidence limits and Glaucoma Hemifield Test results within normal limits. Healthy control eyes also had a healthy appearance of the optic disc and RNFL (no diffuse or focal rim thinning, cupping, optic disc hemorrhage, or RNFL defects), as evaluated by optic disc photographs.

Eyes were classified as glaucomatous if they had repeatable (2 consecutive) abnormal visual field test results, defined as a PSD outside the 95% normal confidence limits or Glaucoma Hemifield Test results outside 99% normal confidence limits, regardless of the appearance of the optic disc. Average MD of the glaucomatous eyes on the visual field test nearest the imaging date was –4.92 dB. According to the Hodapp-Parrish-Anderson29 grading scale of severity of visual field defects, 27 patients (64%) were classified as having early visual field defects, 9 patients (21%) had moderate defects, and 6 patients (14%) had severe visual field defects.

Patients suspected of having glaucoma had either ocular hypertension (IOP >22 mm Hg on more than 2 separate visits) or glaucomatous appearance of the optic disc but normal results on visual field tests. Glaucomatous damage to the optic disc was defined as the presence of neuroretinal rim thinning, excavation, notching, or characteristic RNFL defects. Of the 32 patients suspected of having glaucoma with normal visual fields, 12 (38%) had ocular hypertension and normal optic nerves, whereas 20 (62%) had a glaucomatous appearance of the optic disc.

The RNFL photographs were acquired with a TRC-50VT camera (Topcon America Corp, Paramus, NJ) using Kodak Kodalith high-contrast film (Eastman Kodak Company, Rochester, NY). Superior and inferior 20° fields were obtained using a set of narrow-pass filters (SE-40 and SE-50, Spectrotech Filter, Saugus, Mass) and a standard Topcon red-free filter. In addition, 55° wide-angle views of the optic disc centered between the superior and inferior regions of the RNFL were obtained. Photographs were printed on 35-mm transparencies and viewed on a light box with an acrylic optical grade magnifier (original magnification, x4).

Evaluation of the RNFL photographs was completed using a semiquantitative method described by Niessen et al.30 In this system, photographs were compared with a set of 25 reference photographs, and a point scale was used to score the photographs according to nerve fiber visibility.30-31 A high score of 25 indicated normal, thick, striated fibers, whereas a low score of 1 indicated that no nerve fibers were visible. Superior and inferior arcuate bundles were scored separately. Each photograph was assessed by 2 graders (F.A.M. and K.M.), and the final RNFL score was calculated as the average of the RNFL scores of each grader. Each grader was masked to the subject's identity and the other test results. Disagreements (difference of more than 4 points between the 2 graders) were resolved by consensus of adjudication of a third grader (C.B.). A global severity score (RNFL global) for each eye was created by averaging the superior and inferior final RNFL scores. Poor-quality RNFL photographs, as assessed by consensus of the graders, were discarded. Seventeen patients (13%) of an initial group of 131 eligible patients had poor-quality RNFL photographs and were excluded from the study, leaving 114 subjects for the analysis.

All patients underwent imaging with a commercially available SLP (GDx VCC, software version 5.0.1; Laser Diagnostic Technologies Inc, San Diego, Calif) within 3 months of RNFL photographs. The general principles of SLP have been described in detail elsewhere.8 The GDx VCC is a modified SLP system with VCC. Images of the ocular fundus are formed by scanning the beam of a near infrared laser (780 nm) in a raster pattern. The scan raster covers an image field 40° horizontally and 20° vertically in the eye, covering both the parapapillary and the macular regions.32 In the GDx VCC, the method of VCC, as described by Zhou and Weinreb,25 has been automated and replaced the original fixed corneal compensator. The VCC in the system consists of 2 identical linear retarders in rotating mounts so that both the retardance and axis of the unit can be adjusted according to requirements. To measure eye-specific corneal polarization axis and magnitude, SLP images of the macula are first acquired without compensation (the retardance of the VCC is set to zero). The radial birefringence of the Henle fiber layer in the macula is used as an intraocular polarimeter, and both the Henle fiber layer and corneal retardance can be determined from the macular retardation profile. Next, corneal birefringence-compensated SLP images are obtained using the appropriate eye-specific corneal polarization axis and magnitude values by adjusting the VCC retarders. The GDx VCC measures retardation in units of nanometers. To simplify communications, retardation values are converted into thickness values (micrometers) using a fixed conversion factor of 0.67 nm/µm.32

A baseline image was automatically created from 3 images obtained for each subject and used in each analysis. Only scans of good quality were included. Quality assessment was evaluated by an experienced examiner masked to the subject's identity and results of the other tests. Good-quality image required a focused and evenly illuminated reflectance image with a centered optic disc. Six patients (5%) of an initial group of 131 eligible patients had poor-quality SLP images, and all of them had also poor-quality RNFL photographs.

The GDx VCC software calculates summary parameters based on quadrants, which are defined as temporal (335°-24° unit circle), superior (25°-144°), nasal (145°-214°), and inferior (215°-334°). Both hemifield and global parameters were evaluated. The hemifield SLP parameters investigated in this study were superior ratio (superior quadrant thickness to temporal quadrant thickness), inferior ratio, superior-nasal ratio, superior maximum (average of the 1500 thickest points in the superior quadrant), inferior maximum, superior average, inferior average, normalized superior area (area under the TSNIT [temporal-superior-nasal-inferior-temporal] curve in the superior quadrant), and normalized inferior area. Global SLP parameters investigated were maximum modulation ([thickest quadrant – thinnest quadrant]/thinnest quadrant), ellipse modulation, ellipse average, ellipse standard deviation, and the Nerve Fiber Indicator (NFI). The NFI is calculated using a support vector machine algorithm based on several RNFL measures (Michael Sinai, PhD, Laser Diagnostic Technologies Inc, written communication, March 2003) and assigns a number from 0 to 100 to each eye. The higher the NFI, the greater the likelihood the patient has glaucoma.

Analysis of variance was used to assess differences in SLP parameters and RNFL photography scores among glaucoma patients, patients suspected of having glaucoma, and healthy individuals. The Fisher least-significant difference test was used to perform post hoc multiple comparisons. The correlation between the semiquantitative RNFL severity scores obtained by assessment of RNFL photographs and the SLP parameters was evaluated by Pearson product moment correlation coefficients. The RNFL scores for each hemiretina were compared with SLP parameters evaluating the corresponding hemiretina, whereas global RNFL scores were compared with global SLP parameters.

Receiver operating characteristic (ROC) curves were used to describe the ability to differentiate glaucomatous from healthy eyes of each GDx VCC software–provided parameter and also of the RNFL photographic scoring system. The ROC curve shows the tradeoff between sensitivity and 1 – specificity. An area under the ROC curve of 1.0 represents perfect discrimination, whereas an area of 0.5 represents chance discrimination. The method of DeLong et al33 was used to compare areas under the ROC curve. Minimum specificity cutoffs of 80% and 95% were used for comparing the sensitivity of the SLP parameters and the RNFL photographic scoring method. P<.05 was considered statistically significant. Statistical analyses were performed using SPSS statistical software, version 10.0 (SPSS Inc, Chicago, Ill).


RESULTS
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Author information
 •References

RNFL MEASUREMENTS BY DIAGNOSTIC GROUP

Table 1 gives the mean values of all SLP parameters and RNFL scores in glaucoma patients, patients suspected of having glaucoma, and healthy individuals. Significant differences between glaucoma patients and healthy subjects and between glaucoma patients and patients suspected of having glaucoma were found for all SLP parameters and also for RNFL photographic scores. When patients suspected of having glaucoma were compared with healthy individuals, the SLP parameters NFI, superior maximum, and normalized superior area showed statistically significant differences between the 2 groups.


View this table:
[in this window]
[in a new window]
Table 1. Mean ± SD RNFL Photographic Scores and SLP Parameter Values


ASSOCIATION BETWEEN SLP PARAMETERS AND RNFL SCORES

Table 2 gives the correlation coefficients for the associations between SLP parameters and RNFL photographic scores. All correlations were statistically significant with P<.001. Lower RNFL scores were associated with thinner RNFL thickness measurements as indicated by the SLP parameters. For the superior hemiretina, correlations between superior RNFL scores and corresponding SLP parameters showed R2 values ranging from 16% to 40%. For the inferior hemiretina, the R2 values ranged from 16% to 37%. For the association between global RNFL scores and global SLP parameters, the R2 values ranged from 15% to 47%. The strongest relationship was found between the SLP parameter NFI and the global RNFL score (r = –0.683, R2 = 47%, P<.001, Pearson correlation coefficient). As the SLP parameter NFI increased (more damage), the global RNFL photograph severity score decreased (more damage) (Figure 1).


View this table:
[in this window]
[in a new window]
Table 2. Correlation Coefficients for the Association Between SLP Parameters and RNFL Photographic Scores




View larger version (25K):
[in this window]
[in a new window]
Figure 1. Scatterplot showing the association between the scanning laser polarimetry parameter Nerve Fiber Indicator and the global retinal nerve fiber layer (RNFL) photographic severity score.


We also investigated the correlation between the SLP parameters and RNFL scores with the visual field indices MD and PSD. The SLP parameter NFI showed the best correlation with MD and PSD among the SLP parameters. Higher values of NFI were associated with lower values of MD (r = –0.618, R2 = 38%, P<.001, Pearson correlation coefficient) and higher values of PSD (r = 0.597, R2 = 36%, P<.001, Pearson correlation coefficient). For the RNFL photographic scoring system, lower values of the global RNFL score were significantly associated with lower MD values (r = 0.565, R2 = 32%, P<.001, Pearson correlation coefficient) and higher PSD values (r = –0.526, R2 = 28%, P<.001, Pearson correlation coefficient).

ABILITY OF SLP PARAMETERS AND RNFL PHOTOGRAPHIC SCORING METHOD TO DIFFERENTIATE GLAUCOMA PATIENTS FROM HEALTHY SUBJECTS

Table 3 gives the values of the areas under the ROC curves for all SLP parameters and the RNFL photographic scores. For the SLP parameters, ROC curve areas ranged from 0.65 to 0.91, whereas for the RNFL photographic scoring system, the ROC curve areas were 0.80, 0.84, and 0.84 for the superior, inferior, and global RNFL scores, respectively. The ROC curve area for the best SLP parameter, NFI, was significantly higher than the ROC curve area for the global RNFL score (P = .03) (Figure 2). Table 3 also shows the sensitivities at fixed specificities (>=80% and >=95%) for the SLP parameters and the RNFL photographic scores. With 95% specificity (cutoff point of 30), the NFI had a sensitivity of 71% for detection of glaucoma. At the same specificity (cutoff point of 8), the RNFL global score had a lower sensitivity (36%). With specificity at 80%, the NFI and RNFL global score had similar sensitivities (88% and 81%, respectively). Figure 3 shows the balance of sensitivity and specificity for each cutoff point for the SLP parameter NFI.


View this table:
[in this window]
[in a new window]
Table 3. Areas Under the ROC Curves for Discriminating Between 40 Healthy and 42 Glaucomatous Eyes*




View larger version (18K):
[in this window]
[in a new window]
Figure 2. Receiver operating characteristic curves for the scanning laser polarimetry parameter Nerve Fiber Indicator (NFI) and for the global retinal nerve fiber layer (RNFL) photographic score to discriminate glaucomatous from healthy eyes.




View larger version (23K):
[in this window]
[in a new window]
Figure 3. Sensitivity and specificity values for each cutoff point of the scanning laser polarimetry parameter Nerve Fiber Indicator to discriminate glaucomatous from healthy eyes.


Using 30 as a cutoff point, the NFI classified as having abnormal eyes 9 (28%) of the 32 patients suspected of having glaucoma. Six (67%) of these 9 patients had glaucomatous-appearing optic discs, whereas 3 (33%) had ocular hypertension and normal optic discs. Using 8 as a cutoff point, the RNFL global score classified only 1 (3%) of the 32 patients suspected of having glaucoma as having abnormal eyes. This patient had a glaucomatous-appearing optic disc and was also diagnosed as having abnormal eyes by the NFI.


COMMENT
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Author information
 •References

For both the superior and inferior hemifields, as well as for global RNFL measures, we found moderate correlations between the amount of RNFL damage as assessed by RNFL photographs and GDx VCC software–provided parameters. Because semiquantitative RNFL photographic assessment has been shown to precede detectable optic disc damage and visual field defects in glaucoma,1, 3 the measurements of RNFL thickness obtained with the GDx VCC may provide clinically relevant information for diagnosing and monitoring glaucoma patients and also for detecting early glaucomatous damage.

The correlations found in our study between the SLP parameters and the Niessen semiquantitative RNFL scoring system ranged from a minimum R2 of 15% to a maximum R2 of 47%, depending on the specific SLP parameter evaluated. These values were generally better than previously reported correlations in studies comparing the same RNFL photographic scoring system with earlier versions of SLP using fixed corneal compensation.12-13 Niessen et al12 found a maximum R2 of 28% for the correlation between cross-section RNFL measurements obtained with a nerve fiber analyzer (GDx Nerve Fiber Analyzer; Laser Diagnostic Technologies Inc) and the semiquantitative RNFL photographic scoring system. In another study, Zangwill et al13 found R2 values ranging from 0.35% to 25.7% for the correlation between GDx Nerve Fiber Analyzer (Laser Diagnostic Technologies Inc) parameters and the Niessen photographic scoring method. These findings agree with recent reports that showed an improvement in the correlation coefficients for associations between SLP parameters and other measures of glaucomatous damage, such as visual field indices or optical coherence tomography RNFL thickness measurements, when VCC rather than fixed corneal compensation is used.34-35

The improvement in correlation coefficients with the use of SLP with VCC seems to be most noticeable for thickness parameters than for ratio and modulation ones. In the study by Zangwill et al,13 which used SLP with fixed corneal compensation, the best correlation using a thickness parameter was found between the superior average parameter and the superior hemifield RNFL score. However, the R2 for this correlation was only 5%, whereas in our study the same association had an R2 of 25%. For the ratio and modulation parameters, the best correlation in the study by Zangwill et al13 was found for the ellipse modulation parameter and global RNFL score, with an R2 of 25.7%. In our study, the same association had a comparable R2 of 21.7%. The stronger improvement found for thickness parameters than for ratio and modulation parameters is likely because the latter may already compensate for some of the changes in retardation measurements caused by an inadequate corneal compensation in some patients. This finding is supported by the study by Weinreb et al,26 which showed that the diagnostic ability of several SLP parameters at classifying eyes as glaucomatous or healthy is improved considerably with SLP using VCC as compared with SLP using fixed corneal compensation, particularly for the thickness parameters.

The best correlation in our study was found between the GDx VCC software–provided parameter NFI and the global RNFL photographic score, with an R2 of 47%. This is not a surprising result, because the NFI is calculated using a sophisticated machine learning classifier method that takes into account several parameters of the RNFL and is intended to provide the best measure of the current RNFL status obtained with SLP. Higher values of NFI were also significantly associated with more severe visual field damage, as indicated by the global indices MD and PSD. The correlation between NFI and visual field indices was higher than the association found between the visual field indices and the global RNFL photographic score. Interestingly, the correlation between the 2 methods of RNFL assessment was higher than the correlation between each method and the visual field indices. This is not surprising, since RNFL damage often can precede visual field loss1 and therefore structure-function correlations are expected to be weak at a given point in time.

We also evaluated the ability of the SLP parameters and RNFL photographic scores to discriminate glaucoma patients from healthy individuals. The best SLP parameter, NFI, had a significantly better diagnostic power than any of the RNFL scores evaluated. This was particularly evident for higher specificities. When the specificity was set at 95%, the sensitivity of the NFI to diagnose glaucoma was 71% compared with only 36% for the global RNFL score. At a moderate specificity (80%), the NFI parameter and the RNFL global score had similar sensitivities (88% and 81%, respectively). In a study comparing the ability of several diagnostic tests to distinguish healthy from glaucomatous eyes, Paczka et al36 found that the SLP with fixed corneal compensation had a similar sensitivity compared with a semiquantitative RNFL scoring system, when both methods were evaluated at high-specificity settings.

Besides the apparent better diagnostic ability of the SLP using VCC as compared with the RNFL photographic assessment, other potential advantages of the SLP technology are notable. SLP provides real-time, immediate, and objective assessment of the RNFL and does not require pupil dilation.8, 37 On the other hand, good-quality red-free RNFL photographs are technically difficult to obtain, requiring maximum pupillary dilation and clear ocular media.4 In addition, evaluation of RNFL photographs requires special training and remains a subjective method, even when semiquantitative scoring systems are used. However, potential benefits of RNFL photographic assessment exist, namely its lower cost and the fact that this method has been previously validated by longitudinal studies for early detection of glaucomatous damage.1-3

Both the SLP parameters and the RNFL photographic scoring method were able to find significant differences between glaucoma patients and healthy subjects, as well as between glaucoma patients and patients suspected of having glaucoma. However, only the SLP was able to detect significant differences between those suspected of having glaucoma and healthy individuals, with 3 of the investigated parameters showing statistically significant differences between these 2 groups. Accordingly, using a cutoff with 95% specificity, 28% of those suspected of having glaucoma were classified as having abnormal eyes using the NFI parameter, whereas only 3% of the same subjects were classified as having abnormal eyes using the RNFL global photographic score. If the excess of abnormal eyes in those suspected of having glaucoma over healthy subjects is taken as a measure of true glaucomatous defect among the group with suspected glaucoma, a larger proportion of eyes with early glaucoma damage were identified with the NFI compared with the RNFL photographic scoring method. Although this might indicate an advantage of SLP over conventional RNFL photographic assessment for the identification of early damage in those suspected of having glaucoma, longitudinal studies are still needed to verify this possibility.

In conclusion, a good correlation was found between RNFL assessment using red-free photographs and selected SLP parameters, suggesting that these 2 methods provide comparable information about the status of the RNFL damage in glaucoma. In high-specificity settings, the best parameter from the SLP had better performance than RNFL semiquantitative photographic assessment in the detection of patients with glaucomatous visual field defects and also in the identification of abnormalities in the eyes of patients suspected of having glaucoma.


AUTHOR INFORMATION
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Author information
 •References

Corresponding author: Robert N. Weinreb, MD, Hamilton Glaucoma Center, University of California, San Diego, 9500 Gilman Dr, La Jolla, CA 92093-0946.

Submitted for publication April 24, 2003; final revision received September 7, 2003; accepted October 1, 2003.

This study was supported in part by the Foundation for Eye Research (Dr Medeiros) and National Eye Institute grant EY11008 (Dr Zangwill).

From the Hamilton Glaucoma Center and Department of Ophthalmology, University of California, San Diego. Dr Weinreb is a consultant for and has received research support from Laser Diagnostic Technologies Inc.


REFERENCES
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Author information
 •References

1. Sommer A, Katz J, Quigley HA, et al. Clinically detectable nerve fiber atrophy precedes the onset of glaucomatous field loss. Arch Ophthalmol. 1991;109:77-83. FREE FULL TEXT
2. Sommer A, Miller NR, Pollack I, et al. The nerve fiber layer in the diagnosis of glaucoma. Arch Ophthalmol. 1977;95:2149-2156. FREE FULL TEXT
3. Quigley HA, Katz J, Derick RJ, et al. An evaluation of optic disc and nerve fiber layer examinations in monitoring progression of early glaucoma damage. Ophthalmology. 1992;99:19-28. ISI | PUBMED
4. Quigley HA. Diagnosing Early Glaucoma with Nerve Fiber Layer Examination. New York, NY: Igaku-Shoin; 1996.
5. Weinreb RN, Dreher AW, Coleman A, et al. Histopathologic validation of Fourier-ellipsometry measurements of retinal nerve fiber layer thickness. Arch Ophthalmol. 1990;108:557-560. FREE FULL TEXT
6. Weinreb RN, Zangwill L, Berry CC, et al. Detection of glaucoma with scanning laser polarimetry. Arch Ophthalmol. 1998;116:1583-1589. FREE FULL TEXT
7. Tjon-Fo-Sang MJ, Lemij HG. The sensitivity and specificity of nerve fiber layer measurements in glaucoma as determined with scanning laser polarimetry. Am J Ophthalmol. 1997;123:62-69. ISI | PUBMED
8. Weinreb RN, Shakiba S, Zangwill L. Scanning laser polarimetry to measure the nerve fiber layer of normal and glaucomatous eyes. Am J Ophthalmol. 1995;119:627-636. ISI | PUBMED
9. Bowd C, Zangwill LM, Berry CC, et al. Detecting early glaucoma by assessment of retinal nerve fiber layer thickness and visual function. Invest Ophthalmol Vis Sci. 2001;42:1993-2003. FREE FULL TEXT
10. Zangwill LM, Bowd C, Berry CC, et al. Discriminating between normal and glaucomatous eyes using the Heidelberg Retina Tomograph, GDx Nerve Fiber Analyzer, and Optical Coherence Tomograph. Arch Ophthalmol. 2001;119:985-993. FREE FULL TEXT
11. Choplin NT, Lundy DC, Dreher AW. Differentiating patients with glaucoma from glaucoma suspects and normal subjects by nerve fiber layer assessment with scanning laser polarimetry. Ophthalmology. 1998;105:2068-2076. FULL TEXT | ISI | PUBMED
12. Niessen AG, Van Den Berg TJ, Langerhorst CT, Greve EL. Retinal nerve fiber layer assessment by scanning laser polarimetry and standardized photography. Am J Ophthalmol. 1996;121:484-493. ISI | PUBMED
13. Zangwill L, Knauer S, Williams JM, Weinreb RN. Retinal nerve fiber layer assessment by scanning laser polarimetry, optical coherence tomography and retinal nerve fiber layer photography. In: Lemij HG, Schuman JS, eds. The Shape of Glaucoma: Quantitative Neural Imaging Techniques. The Hague, the Netherlands: Kugler Publications; 2000.
14. Weinreb RN. Evaluating the retinal nerve fiber layer in glaucoma with scanning laser polarimetry. Arch Ophthalmol. 1999;117:1403-1406. FREE FULL TEXT
15. Garway-Heath DF, Greaney MJ, Caprioli J. Correction for the erroneous compensation of anterior segment birefringence with the scanning laser polarimeter for glaucoma diagnosis. Invest Ophthalmol Vis Sci. 2002;43:1465-1474. FREE FULL TEXT
16. Greenfield DS, Knighton RW, Feuer WJ, et al. Correction for corneal polarization axis improves the discriminating power of scanning laser polarimetry. Am J Ophthalmol. 2002;134:27-33. FULL TEXT | ISI | PUBMED
17. Greenfield DS, Knighton RW, Huang XR. Effect of corneal polarization axis on assessment of retinal nerve fiber layer thickness by scanning laser polarimetry. Am J Ophthalmol. 2000;129:715-722. FULL TEXT | ISI | PUBMED
18. Knighton RW, Huang XR, Greenfield DS. Analytical model of scanning laser polarimetry for retinal nerve fiber layer assessment. Invest Ophthalmol Vis Sci. 2002;43:383-392. FREE FULL TEXT
19. Greenfield DS, Knighton RW, Feuer WJ, Schiffman JC. Normative retardation data corrected for the corneal polarization axis with scanning laser polarimetry. Ophthalmic Surg Lasers Imaging. 2003;34:165-171. ISI | PUBMED
20. Van Blokland GJ, Verhelst SC. Corneal polarization in the living human eye explained with a biaxial model. J Opt Soc Am A. 1987;4:82-90. ISI | PUBMED
21. Brink HB, van Blokland GJ. Birefringence of the human foveal area assessed in vivo with Mueller-matrix ellipsometry. J Opt Soc Am A. 1988;5:49-57. ISI | PUBMED
22. Knighton RW, Huang XR. Linear birefringence of the central human cornea. Invest Ophthalmol Vis Sci. 2002;43:82-86. FREE FULL TEXT
23. Brink HB. Birefringence of the human crystalline lens in vivo. J Opt Soc Am A. 1991;8:1788-1793. ISI | PUBMED
24. Weinreb RN, Bowd C, Greenfield DS, Zangwill LM. Measurement of the magnitude and axis of corneal polarization with scanning laser polarimetry. Arch Ophthalmol. 2002;120:901-906. FREE FULL TEXT
25. Zhou Q, Weinreb RN. Individualized compensation of anterior segment birefringence during scanning laser polarimetry. Invest Ophthalmol Vis Sci. 2002;43:2221-2228. FREE FULL TEXT
26. Weinreb RN, Bowd C, Zangwill LM. Glaucoma detection using scanning laser polarimetry with variable corneal polarization compensation. Arch Ophthalmol. 2003;121:218-224. FREE FULL TEXT
27. Weinreb RN, Bowd C, Zangwill LM. Assessment of the retinal nerve fiber layer of the normal and glaucomatous monkey with scanning laser polarimetry. Trans Am Ophthalmol Soc. 2002;100:161-167. PUBMED
28. Weinreb RN, Bowd C, Zangwill LM. Scanning laser polarimetry in monkey eyes using variable corneal polarization compensation. J Glaucoma. 2002;11:378-384. FULL TEXT | ISI | PUBMED
29. Hodapp E, Parrish RK II, Anderson DR. Clinical Decisions in Glaucoma. St Louis, Mo: Mosby–Year Book; 1993.
30. Niessen AG, van den Berg TJ, Langerhorst CT, Bossuyt PM. Grading of retinal nerve fiber layer with a photographic reference set. Am J Ophthalmol. 1995;120:577-586. ISI | PUBMED
31. Niessen AG, van den Berg TJ. Evaluation of a reference set based grading system for retinal nerve fiber layer photographs in 1941 eyes. Acta Ophthalmol Scand. 1998;76:278-282. FULL TEXT | ISI | PUBMED
32. Zhou Q, Reed J, Betts R, et al. Detection of glaucomatous retinal nerve fiber layer damage by scanning laser polarimetry with variable corneal compensation. Paper presented at: SPIE Ophthalmic Technologies XIII: BiOS 2003; January 25, 2003; San Jose, Calif. Conference 4951.
33. DeLong ER, DeLong DM, Clarke-Pearson DL. Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach. Biometrics. 1988;44:837-845. FULL TEXT | ISI | PUBMED
34. Bowd C, Zangwill L, Weinreb RN. The association between scanning laser polarimetry measurements using variable corneal polarization compensation and visual field sensitivity in glaucomatous eyes. Arch Ophthalmol. 2003;121:961-966. FREE FULL TEXT
35. Bagga H, Greenfield DS, Feuer W, Knighton RW. Scanning laser polarimetry with variable corneal compensation and optical coherence tomography in normal and glaucomatous eyes. Am J Ophthalmol. 2003;135:521-529. FULL TEXT | ISI | PUBMED
36. Paczka JA, Friedman DS, Quigley HA, et al. Diagnostic capabilities of frequency-doubling technology, scanning laser polarimetry, and nerve fiber layer photographs to distinguish glaucomatous damage. Am J Ophthalmol. 2001;131:188-197. FULL TEXT | ISI | PUBMED
37. Hoh ST, Greenfield DS, Liebmann JM, et al. Effect of pupillary dilation on retinal nerve fiber layer thickness as measured by scanning laser polarimetry in eyes with and without cataract. J Glaucoma. 1999;8:159-163. ISI | PUBMED


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter     What's this?

THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

The Effect of Acute Intraocular Pressure Elevation on Peripapillary Retinal Thickness, Retinal Nerve Fiber Layer Thickness, and Retardance
Fortune et al.
IOVS 2009;50:4719-4726.
ABSTRACT | FULL TEXT  

Detection of Progressive Retinal Nerve Fiber Layer Loss in Glaucoma Using Scanning Laser Polarimetry with Variable Corneal Compensation
Medeiros et al.
IOVS 2009;50:1675-1681.
ABSTRACT | FULL TEXT  

Longitudinal Variability of Optic Disc and Retinal Nerve Fiber Layer Measurements
Leung et al.
IOVS 2008;49:4886-4892.
ABSTRACT | FULL TEXT  

Intravitreal Colchicine Causes Decreased RNFL Birefringence without Altering RNFL Thickness
Fortune et al.
IOVS 2008;49:255-261.
ABSTRACT | FULL TEXT  

Detection of Glaucoma Using Scanning Laser Polarimetry with Enhanced Corneal Compensation
Medeiros et al.
IOVS 2007;48:3146-3153.
ABSTRACT | FULL TEXT  

American Chinese Glaucoma Imaging Study: A Comparison of the Optic Disc and Retinal Nerve Fiber Layer in Detecting Glaucomatous Damage
Leung et al.
IOVS 2007;48:2644-2652.
ABSTRACT | FULL TEXT  

Influence of disease severity and optic disc size on the diagnostic performance of imaging instruments in glaucoma.
Medeiros et al.
IOVS 2006;47:1008-1015.
ABSTRACT | FULL TEXT  

Comparative Study of Retinal Nerve Fiber Layer Measurement by StratusOCT and GDx VCC, I: Correlation Analysis in Glaucoma
Leung et al.
IOVS 2005;46:3214-3220.
ABSTRACT | FULL TEXT  

Relevance Vector Machine and Support Vector Machine Classifier Analysis of Scanning Laser Polarimetry Retinal Nerve Fiber Layer Measurements
Bowd et al.
IOVS 2005;46:1322-1329.
ABSTRACT | FULL TEXT  

Comparison of the GDx VCC Scanning Laser Polarimeter, HRT II Confocal Scanning Laser Ophthalmoscope, and Stratus OCT Optical Coherence Tomograph for the Detection of Glaucoma
Medeiros et al.
Arch Ophthalmol 2004;122:827-837.
ABSTRACT | FULL TEXT  





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 2004 American Medical Association. All Rights Reserved.