You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 122 No. 12, December 2004 TABLE OF CONTENTS
  Archives
  •  Online Features
  Clinical Sciences
 This Article
 •Abstract
 •PDF
 • Reply to article
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on HighWire
 •Citing articles on ISI (2)
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Topic Collections
 •Optics/ Refraction
 •Pediatric Ophthalmology
 •Alert me on articles by topic

Corneal Topography of Neonates and Infants

Sherwin J. Isenberg, MD; Madeline Del Signore, RN; Anthony Chen, MD; Jefferey Wei, MD; Peter D. Christenson, PhD

Arch Ophthalmol. 2004;122:1767-1771.

ABSTRACT

Objective  To evaluate corneal curvature by direct topographic analysis during the first 6 months of life.

Methods  We evaluated corneal topography in 200 infants using a specialized handheld topographic instrument at a mean of 1.6 days after birth, and in some again at 3 and 6 months in the newborn nursery and ophthalmology clinic of a public hospital.

Results  At birth, the mean central corneal power measured 48.5 diopters (D) (95% confidence interval [CI], 48.2-48.8 D; range, 41.4-56.0 D) and astigmatism measured 6.0 D (95% CI, 5.6-6.3 D), usually "with the rule" (80%) with a mean axis of 95°. The mean astigmatism on the semimeridian map at 3 mm was 6.4 D (95% CI, 6.0-6.8 D); and at 5 mm, 5.9 D (95% CI, 5.4-6.3 D). At birth, neonates delivered vaginally had a greater frequency of with-the-rule astigmatism than those delivered by cesarean section (P = .02). By 6 months, the mean central corneal power and astigmatism decreased to 43.0 (95% CI, 41.3-43.1) D and 2.3 (95% CI, 1.4-3.2) D, respectively (P<.005 for each).

Conclusions  Newborns have steep, high, astigmatic (generally with-the-rule) corneas at birth that flatten significantly by the age of 6 months. The method of delivery can affect the astigmatic axis at birth.



INTRODUCTION
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Author information
 •References

The shape of the corneal surface in infants has been quite steep in several studies. Clinicians have appreciated this steepness when donor corneas from infants were transplanted onto adult recipients, resulting in keratometry measurements averaging 57.7 diopters (D).1

Few studies have attempted to directly measure corneal curvature in neonates and infants. Most had a small sample size and used techniques to determine the refractive error and then secondarily implied the contribution of the cornea. Others have used keratometers. Keratometers, however, assume a spherocylindrical corneal shape and are limited to monitoring the corneal curvature based on 4 points. Placido disc–based videokeratography, as used in this study, has provided reliable data about the anterior corneal surface, approaching the spherocylindrical ideal.2-3

To our knowledge, this study is the first to evaluate corneal curvature by direct topographic analysis in neonates and infants, as determined by a search on the PubMed Web site of the National Library of Medicine and in our literature review.


METHODS
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Author information
 •References

The Human Subjects Committee of the Harbor-UCLA Medical Center approved the protocol. Written informed consent was obtained from each mother before her child was studied. The infants were securely wrapped in a swaddling cloth. The eyelids were separated with 2 cotton-tipped applicators and were always elevated off the ocular surface. Great care was taken to apply the applicators only to the upper and lower rims of the orbit. No pressure was applied directly on the eye.

The topography of each cornea was then studied with a specialized topographic instrument (Vista Handheld Corneal Topographer; EyeSys Premier, Irvine, Calif), a Placido disc–based system. Before each use, the instrument was calibrated according to the manufacturer’s instructions. A study was accepted only if at least 3 complete Placido rings were visible, centered, and properly focused on the recorded image. If these criteria were not met, the study was repeated until the criteria were satisfied. The data were directly downloaded to a portable computer and analyzed with software for the topographic instrument.

Data for each eye of each infant, where available, were used in all statistical analyses, summarized with means and frequencies over all eyes. Confidence intervals (CIs) and statistical comparisons that incorporate the correlation between the 2 eyes of an individual were used to include all available data without inflating the precision of estimates. Linear mixed models with compound symmetric correlation were used for corneal power and astigmatism.4-5 Generalized estimating equations with a binomial distribution and a logit-link function were used to compare "with-the-rule" astigmatism between vaginal and cesarean section deliveries, incorporating within-subject correlation between eyes.6 Analyses were performed with modules (Mixed and Genmod) in SAS statistical software, version 8.2.7 To verify the validity of the topographic system, we compared the keratometric data of 22 adult eyes, as measured by the same system, with measurements obtained from 2 other instruments (IOLMaster [Carl Zeiss, Jena, Germany] and ARK-760A [Marco, Jacksonville, Fla]).


RESULTS
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Author information
 •References

Of the 200 neonates studied, 95 were female. All newborns who met the criteria and whose parent consented were consecutively recruited for the study from March 7, 1999, through June 6, 2000. The racial proportion was as follows: 74% Latin American, 12% African American, 8% white, and 5% other (percentages do not total 100 because of rounding). The mean ± SD birth weight was 3318 ± 543 g (range, 1890-5030 g). At examination, the mean ± SD postnatal age was 1.6 ± 1.2 days (range, 0-8 days), and the mean ± SD postconceptional age was 39.3 ± 1.7 weeks (range, 29.9-42.7 weeks). Repeat examinations were conducted at a mean ± SD of 3.0 ± 0.5 and 6.0 ± 0.5 postnatal months.

For the neonates, the mean central corneal power was 48.5 (range, 41.4-56.0) D. The mean keratometric astigmatism was 6.0 (range, 0.2-16.4) D. The mean astigmatism on the semimeridian map at 3 mm was 6.4 (range, 0.01-22.5) D; and at 5 mm, 5.9 (range, 1.1-18.3) D.

The mean axis of the astigmatism in the neonates was 95.0°. Most of the astigmatic axes (80%) were with the rule (within 20° of 90°), while 19% were at an oblique axis and less than 1% were "against the rule" (within 20° of 180°).

Neonates delivered vaginally had the same (P = .49) mean central corneal power (48.5 D; 95% CI, 48.2-48.9 D) as those delivered by cesarean section (48.5 D; 95% CI, 47.7-48.9 D). The astigmatism was also the same (P = .47): 6.0 (95% CI, 5.6-6.4) D and 6.0 (95% CI, 5.0-6.4) D, respectively. By 3 months, the difference for central corneal power was 44.5 (95% CI, 43.4-45.6) D and 44.1 (95% CI, 42.7-45.3) D, respectively, and the astigmatism was 3.6 (95% CI, 2.6-4.5) D and 2.9 (95% CI, 1.6-3.9) D, respectively; these values were also not statistically different (P>.30).

However, the type of delivery was related to the astigmatic axis. At birth, neonates delivered vaginally had a greater frequency of with-the-rule astigmatism (83%) than those delivered by cesarean section (72%) (P = .02). By 3 months, the frequencies were similar (86% and 73%, respectively) to those at birth, but nonsignificant (P = .37) because of the reduced number of infants observed at this point. There are insufficient data for comparison at 6 months.

The follow-up data for the 3- and 6-month examinations are given in the Table. Figure 1 and Figure 2 show examples of differential maps from birth to the ages of 3 and 6 months, respectively. The decreases in central power and astigmatism from birth to the 3- and 6-month measurements were statistically significant (P<.005). From 3 to 6 months, the reductions in central power and astigmatism were not significant (P = .93 and P = .14, respectively). Frequencies of type of astigmatism are almost identical at birth and at 3 months. An observed reduction in frequency of with-the-rule astigmatism at 6 months is nonsignificant (P>.10).


View this table:
[in this window]
[in a new window]
Table. Corneal Variables During the First 6 Postnatal Months




View larger version (45K):
[in this window]
[in a new window]
Figure 1. An axial corneal topographical map of a right eye at birth (A) and at 3 months (B). The central corneal power decreased from 49.1 to 45.1 diopters (D), and the astigmatism diminished from 5.7 D at 96° to 2.5 D at 111°.




View larger version (44K):
[in this window]
[in a new window]
Figure 2. An axial corneal topographical map of one of the steeper left eye corneas at birth (A) and at 6 months (B). The central corneal power decreased from 54.9 to 47.3 diopters (D), and the astigmatism diminished from 8.1 D at 116° to 0.1 D at 5°.


For all comparisons at all ages studied, there were no statistically significant differences whether the infants were stratified by sex or race (P>.05 for all).

The validation studies on the adult eyes found no significant differences among the instruments (P>.70). For steepest and flattest meridians compared with a different instrument (IOLMaster), the topographic system used (Vista) demonstrated a mean difference of 0.13 D flatter and 0.03 D steeper. The numbers for the comparison with the second instrument (ARK-760A) were 0.1 D steeper and 0.2 D steeper.


COMMENT
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Author information
 •References

SPHERICAL VALUES

There have been few studies that directly measured corneal curvature in newborns. In 1976, Ehlers and colleagues8 reported the mean ± SD corneal curvature in 19 mature newborns to be 7.1 ± 0.07 mm using a keratometer. By using an ophthalmometer on neonates, Gordon and Donzis9 found the mean ± SD apical keratometry to decrease from 53.6 ± 2.5 D in 11 eyes at 30 to 35 postconceptional weeks to 51.2 ± 1.1 D in 10 eyes at 39 to 41 postconceptional weeks. In 11 infants younger than 1 year, they found the mean ± SD keratometric value to further decrease to 45.2 ± 1.3 D. There was no measurement of astigmatism. While these numbers are higher than our corresponding numbers of 48.5 D at birth and 43.0 D at 6 months, their measurements are within 1 SD of our findings. Interestingly, the nearly 6-D reduction they found from birth to 1 year is quite similar to the reduction from birth to 6 months reported in this study. In Japan, Inagaki10 performed automated keratometry on 11 mature neonates and found a mean ± SD keratometry reading of 47.0 ± 1.2 D. The curvature decreased to a mean ± SD of 44.1 ± 1.7 D by the age of 3 months in the 8 infants he followed up. These numbers are close to the results of this investigation. A 2004 study, which used a keratometer, reported higher values than those found in this study—58.6 D horizontally and 54.0 D vertically when averaging both eyes.11

The use of infantile corneas for keratoplasty to adult recipients has been reported. Koenig and associates1 believed that the large value of 57.7 D following such a keratoplasty might reflect a steepening effect induced by suturing the relatively elastic infantile cornea to an adult recipient. Wood and Nissenkorn12 attributed the myopia found in their adult recipients of infant corneas to corneal steepness, with an average keratometry reading in the adults of 46.5/50.9 D.

ASTIGMATIC CYLINDER VALUES

In a 2004 study, Friling and associates,11 using keratometry, reported 6 D of cylinder in their 32 infants whose postconceptual age was younger than 32 weeks and 3.3 D for the 30 infants whose postconceptual age was older than 36 weeks.

The nature and amount of astigmatism reported in neonates and infants are controversial. By using near retinoscopy without cycloplegia, Mohindra and colleagues13 found that, of 17 newborns younger than 1 week, about 20% had astigmatism of 2 D or more. The same 20% proportion was still present at the age of 6 months. In a later report, astigmatism of at least 1 D in 55% of infants younger than 5 months was found, with 10% displaying a cylinder exceeding 3 D.14

By using photorefractive techniques, Howland and associates15 studied 15 neonates younger than 10 days, and reported that 50% had astigmatism, with 25% exceeding 1 D. At the age of 6 months, the proportion was also parallel. With similar methods, Atkinson and coworkers16 found that almost all of their 20 infants at the age of 3 months had at least 1 D of astigmatism and that the quantity was reduced to adult levels by the age of 18 months. Weale17 calculated that the with-the-rule astigmatism should measure 3.5 D in white and 5.8 D in Japanese neonates.

We measured a greater mean astigmatism at birth (5.6 D) and 3 months (3.3 D) than these previous studies. This could be attributed to the strong possibility that the direct topographical analysis used in this study is more accurate than the other methods attempted. To ensure that the handheld system we used was as accurate as other instruments, we compared it with 2 other devices and found the measurements nearly identical among the 3. It is also possible that we measured the neonates closer to birth (mean, 1.6 days, with some as early as a few hours after birth) than the other studies. Thus, we would more likely appreciate the direct effects of the birth process, which may have compressed the eye and produced a larger astigmatism than reported in previous studies. By the age of 6 months, our findings (2.3 D) are more similar to previously reported values.

Most cesarean section deliveries were begun after the neonate’s head was already engaged in the birth canal. This would explain our finding that a vaginal delivery caused a similar amount of astigmatism as a cesarean delivery.

AXIS OF ASTIGMATISM

Previous reports of the axis of astigmatism in newborns and infants are even more contradictory. By using near retinoscopy without cycloplegia, Gwiazda and coworkers14 examined 440 infants younger than 5 months. They found that the astigmatism of at least 1 D that was present in 235 infants was with the rule in 45% of the cases and against the rule in 45%. This study was somewhat contradicted by a subsequent investigation by Thorn and colleagues.18 Also using near retinoscopy without cycloplegia, Thorn et al reported that 51% of 45 white infants (aged 31/2-11.8 months) had with-the-rule astigmatism and only 13% had against-the-rule astigmatism. They also reported that 59% of 22 Chinese infants (aged 31/2-12 months) had against-the-rule astigmatism.

There are potential problems with studies using near retinoscopy. Wesson and colleagues19 found significant differences between near retinoscopy and cycloplegic refraction for sphere and cylinder power, especially in infants. Maino and coworkers20 found near retinoscopy and cycloplegic retinoscopy to agree (within 0.5 D) in only 27% of 311 children between the ages of 18 and 48 months. Saunders21 indicated several potential sources for error using this technique, including not neutralizing the meridians simultaneously when cycloplegia is not used and performing retinoscopy off axis, especially in the highly curved infant cornea. She also was concerned about the large disparity in the angle between the visual and optical axes (angle {alpha}) in newborns (8°-10°) compared with adults (4°-5°). This angle {alpha} effect might influence not only retinoscopy but also techniques using cameras for photorefraction. Indeed, using isotropic and orthogonal photorefractive techniques, Howland and Sayles22 reported an against-the-rule astigmatism rate of about 50% in 76 astigmatic infants younger than 1 year (mean age, 6 months).

In a recent study, Mayer and colleagues23 reported that all their 1-month-old infants with greater than 1 D of cylinder demonstrated a with-the-rule axis. By the age of 6 months, the proportion had decreased to about a third. Weale17 postulated that the with-the-rule astigmatism and corneal ellipticity found in newborns are attributable to the oblate form of the fetal eye, supported by the observation that the young cornea yields less to stress than does the sclera.

Our findings of with-the-rule astigmatism in about 80% of infants at birth and at the age of 3 months show a greater preponderance of with-the-rule astigmatism than previous studies. Possible explanations for this discrepancy might include the increased accuracy implicit in this study by using direct corneal topography instead of somewhat subjective retinoscopy or photographic techniques. Our observation of the with-the-rule frequency decreasing to 50% by the age of 6 months, while the oblique and against-the-rule groups were increasing (which is, however, based on only 8 infants) is consistent with the general trend over life to shift from with-the-rule to against-the-rule astigmatism.24

The type of delivery was related to the astigmatic axis. At birth, with-the-rule astigmatism was more frequent in neonates delivered vaginally (83%) than in those delivered by cesarean section (72%) (P = .02). Because cesarean sections were generally begun shortly after the head was engaged in the birth canal, the angle of compression on the eye may have been different than following a complete vaginal delivery. A similar difference according to type of delivery was observed at 3 months, but is not statistically significant because fewer infants were observed at this point.

This study does have limitations. To open the eyelids, we used cotton-tipped applicators. To minimize the possibility that pressure was exerted on the globe, we applied direct pressure only to the orbital rims and actually generally elevated the eyelids off of the ocular surface. We chose this method because previous studies found problems using an eyelid speculum. Masci25 demonstrated that use of a speculum reduced the cylinder in with-the-rule subjects by a mean ± SD of 0.7 ± 0.2 D, and increased the cylinder in against-the-rule subjects by a mean ± SD of 0.2 ± 0.2 D. Wilson and colleagues26 found that, for eyes with toricity greater than 0.6 D with the rule, the mean shift induced by an eyelid speculum was –0.1 D vertically and –0.4 D horizontally. Shea and associates27 recently reported that the use of eyelid specula affects the measured cycloplegic refraction when children are under anesthesia. For children younger than 4 years, the measured cylinder had an average difference of 1.7 D when comparing 2 different types of eyelid specula (P<.001). Recently, the use of an eyelid speculum in children was shown to increase the intraocular pressure an average of 4 mm Hg.28 To avoid the artifact induced by using a speculum, we decided to use a manual technique. It is possible that despite our efforts, some pressure may have contacted the globe in some infants. We also lost several infants for the 3- and 6-month follow-up examinations. These were healthy infants with little reason to return for the examination, despite our efforts to contact all of them.

In conclusion, corneal topography determinations in neonates reveal steep, high, astigmatic (generally, with-the-rule) measurements at birth that flatten significantly by the age of 6 months. The method of delivery affects the astigmatic axis at birth, but not the amount of astigmatic cylinder.


AUTHOR INFORMATION
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Author information
 •References

Correspondence: Sherwin J. Isenberg, MD, Department of Ophthalmology, Harbor-UCLA Medical Center, 1000 W Carson St, Torrance, CA 90509 (isenberg{at}ucla.edu).

Submitted for Publication: November 14, 2003; final revision received April 12, 2004; accepted June 1, 2004.

Funding/Support: This study was supported in part by General Clinical Research Center grant MO01 RR00425 from the National Center for Research Resources, Bethesda, Md; the Sara Kolb Fund, Los Angeles, Calif; the Kirchgessner Foundation, Los Angeles; and a Senior Scientific Investigator Award from Research to Prevent Blindness, New York, NY (Dr Isenberg).

Acknowledgment: We thank Robert Maloney, MD, for his advice and review of the manuscript; and Nancy Berman, PhD, for her statistical services.

Financial Disclosure: None.

Author Affiliations: Jules Stein Eye Institute, Departments of Ophthalmology and Pediatrics, Research and Education Institute at Harbor-UCLA Medical Center, The David Geffen School of Medicine at UCLA, Los Angeles and Torrance, Calif.


REFERENCES
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Author information
 •References

1. Koenig S, Graul E, Kaufman HE. Ocular refraction after penetrating keratoplasty with infant donor corneas. Am J Ophthalmol. 1982;94:534-539. ISI | PUBMED
2. Wilson SE, Ambrosio R. Computerized corneal topography and its importance to wavefront technology. Cornea. 2001;20:441-454. FULL TEXT | ISI | PUBMED
3. Hannush SB, Crawford SL, Waring GO, et al. Reproducibility of normal corneal power measurements with a keratometer, photokeratoscope, and video imaging system. Arch Ophthalmol. 1990;108:539-544. ABSTRACT
4. Rosner B. Statistical methods in ophthalmology: an adjustment for the intraclass correlation between eyes. Biometrics. 1982;38:105-114. FULL TEXT | ISI | PUBMED
5. Brown H, Prescott R. Applied Mixed Models in Medicine. New York, NY: John Wiley & Sons Inc; 1999.
6. Zeger SL, Liang KY. Longitudinal data analysis for discrete and continuous outcomes. Biometrics. 1986;42:121-130. FULL TEXT | ISI | PUBMED
7. Littell RC, Miliken GA, Stroup WW, Wolfinger RD. SAS System for Mixed Models. Cary, NC: SAS Institute Inc; 1996.
8. Ehlers N, Sorensen T, Bramsen T, Poulsen EH. Central corneal thickness in newborns and children. Acta Ophthalmol (Copenh). 1976;54:285-290.
9. Gordon RA, Donzis PB. Refractive development of the human eye. Arch Ophthalmol. 1985;103:785-789. ABSTRACT
10. Inagaki Y. The rapid change of corneal curvature in the neonatal period and infancy. Arch Ophthalmol. 1986;104:1026-1027. ABSTRACT
11. Friling R, Weinberger D, Kremer I, Avisar R, Sirota L, Snir M. Keratometry measurements in preterm and full term newborn infants. Br J Ophthalmol. 2004;88:8-10. FREE FULL TEXT
12. Wood TO, Nissenkorn I. Infant donor corneas for penetrating keratoplasty. Ophthalmic Surg. 1981;12:500-502. ISI | PUBMED
13. Mohindra I, Gwiazda J, Brill S. Astigmatism in infants. Science. 1978;202:329-331. FREE FULL TEXT
14. Gwiazda J, Scheiman M, Mohindra I, Held R. Astigmatism in children: changes in axis and amount from birth to six years. Invest Ophthalmol Vis Sci. 1984;25:88-92. ABSTRACT
15. Howland HC, Atkinson J, Braddock O, French J. Infant astigmatism measured by photorefraction. Science. 1978;202:331-333. FREE FULL TEXT
16. Atkinson J, Braddick O, French J. Infant astigmatism: its disappearance with age. Vision Res. 1980;20:891-893. FULL TEXT | ISI | PUBMED
17. Weale RA. Corneal shape and astigmatism: with a note on myopia. Br J Ophthalmol. 1988;72:696-699. FREE FULL TEXT
18. Thorn F, Held R, Fang LL. Orthogonal astigmatic axes in Chinese and Caucasian infants. Invest Ophthalmol Vis Sci. 1987;28:191-194. FREE FULL TEXT
19. Wesson MD, Mann KR, Bray NW. A comparison of cycloplegic refraction to the near retinoscopy technique for refractive error determination. J Am Optom Assoc. 1990;61:680-684. PUBMED
20. Maino JH, Cibis GW, Cress P, Spellman CR, Shores RE. Noncycloplegic vs cycloplegic retinoscopy in pre-school children. Ann Ophthalmol. 1984;16:880-882. ISI | PUBMED
21. Saunders KJ. Early refractive development in humans. Surv Ophthalmol. 1995;40:207-216. FULL TEXT | ISI | PUBMED
22. Howland HC, Sayles N. Photorefractive measurements of astigmatism in infants and young children. Invest Ophthalmol Vis Sci. 1984;25:93-102. ABSTRACT
23. Mayer DL, Hansen RM, Moore BD, Kim S, Fulton AB. Cycloplegic refractions in healthy children aged 1 through 48 months. Arch Ophthalmol. 2001;119:1625-1628. FREE FULL TEXT
24. Hayashi K, Hayashi H, Hayashi F. Topographic analysis of the changes in corneal shape due to aging. Cornea. 1995;14:527-532. ISI | PUBMED
25. Masci E. Sull’astigmatismo oftalmometrico: modificazioni della curvature corneale in rapporto alla attivita palpebrale ed alla rigidita sclerale. Boll Ocul. 1965;44:755-763. PUBMED
26. Wilson G, Bell C, Chotai S. The effect of lifting the lids on corneal astigmatism. Am J Optom Physiol Opt. 1982;59:670-674. ISI | PUBMED
27. Shea CJ, Westfall KC, MacKenzie T, Bateman JB. Comparison of measured astigmatic retinoscopies from different lid specula. J AAPOS. 2001;5:357-360.
28. Epley KD, Tychsen L, Lueder GT. The effect of an eyelid speculum on intraocular pressure measurement in children. Am J Ophthalmol. 2002;134:926-927. FULL TEXT | ISI | PUBMED


THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

Keratometry in Pediatric Eyes With Cataract
Trivedi and Wilson
Arch Ophthalmol 2008;126:38-42.
ABSTRACT | FULL TEXT  





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 2004 American Medical Association. All Rights Reserved.