You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 122 No. 11, November 2004 TABLE OF CONTENTS
  Archives
  •  Online Features
  Clinical Sciences
 This Article
 •Abstract
 •PDF
 • Reply to article
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on HighWire
 •Citing articles on ISI (14)
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Topic Collections
 •Macular Degeneration
 •Ocular Imaging
 •Articles for Residents
 •Alert me on articles by topic

Detection of Age-Related Macular Degeneration Using a Nonmydriatic Digital Camera and a Standard Film Fundus Camera

Ronald Klein, MD, MPH; Stacy M. Meuer, BS; Scot E. Moss, MA; Barbara E. K. Klein, MD, MPH; Michael W. Neider, BA; Jennifer Reinke, BS

Arch Ophthalmol. 2004;122:1642-1646.

ABSTRACT

Objective  To compare gradings of lesions associated with age-related macular degeneration (AMD) from digital and stereoscopic film images.

Design  Instrument validation study.

Participants  Sixty-two subjects (124 eyes) with varying degrees of AMD, including no AMD.

Methods  Images of the optic disc and macula were taken using a 45° digital camera (6.3 megapixels) through dark-adapted pupils and pharmacologically dilated pupils. In addition, 30° stereoscopic retinal film images were taken through pharmacologically dilated pupils of the same eyes. All images were graded for drusen size, type, and area; pigmentary abnormalities; geographic atrophy; and neovascular lesions using the modified Wisconsin Age-Related Maculopathy Grading System. Exact agreement and unweighted {kappa} scores were calculated for paired gradings resulting from digital and film images.

Main Outcome Measure  Agreement between gradings obtained from stereoscopic slide transparencies and digital nonstereoscopic images.

Results  Exact agreement between gradings of digital and stereoscopic film images taken through pharmacologically dilated pupils was 91% ({kappa} = 0.85) for the categories of none, early AMD, and late AMD. Exact agreement for gradings of digital images taken through dark-adapted pupils compared with gradings of film images was 80% ({kappa} = 0.69). Exact agreement for gradings of digital images captured through dark-adapted and pharmacologically dilated pupils was 86% ({kappa} = 0.78). In addition, {kappa} scores for agreement between different approaches for individual lesions were moderate to almost perfect.

Conclusions  Gradings resulting from high-resolution digital images, especially when the pupil is pharmacologically dilated, are comparable with those resulting from film-based images. We conclude that digital imaging of the retina is useful for epidemiological studies of AMD.



INTRODUCTION
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Author information
 •References

Age-related macular degeneration (AMD) is a major cause of visual impairment.1-2 Fundus photography with film-based cameras has routinely been used to document the presence and severity of AMD in clinical practice and epidemiological studies.3-4 Optimally, fundus photography is performed through a pharmacologically dilated pupil. However, in situations in which mydriatic agents cannot be used, photography with film-based nonmydriatic cameras has successfully been used as an alternative means of imaging for AMD.5-7

Recently, new high-resolution digital cameras have become available and are being used to detect AMD in research and clinical settings.8-10 The purpose of this article is to compare the severity of AMD using images of the same retinas recorded with 3 different imaging systems: nonstereoscopic color 45° retinal images taken with a digital camera through a dark-adapted pupil, nonstereoscopic color 45° retinal images taken with a digital camera through a pharmacologically dilated pupil, and stereoscopic color 30° retinal images taken with a standard film camera through a pharmacologically dilated pupil. In addition, patient acceptance of these imaging systems was compared.


METHODS
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Author information
 •References

SUBJECTS

Our study included 62 patients seen at the University of Wisconsin Retina Clinic (Madison). We attempted to recruit at least 30 patients with a diagnosis of AMD. Tenets of the Declaration of Helsinki were followed, and approval from the institutional human experimentation committee was granted. Informed consent was obtained from each participant. Birth dates and history of cataract, cataract surgery, diabetes, AMD, and retinal photocoagulation were ascertained in 58 subjects (4 patients did not provide a history).

PHOTOGRAPHY

Participants were seated in a darkened room. Pupil size was estimated by comparing it to progressively increasing circles from 1 to 9 mm in diameter. Both eyes of each participant were photographed in a similar fashion using a 45° 6.3-megapixel digital nonmydriatic camera (Canon, Lake Success, NY). This camera used an infrared light to televise a view of the fundus through a dark-adapted pupil. Field location and focusing of the retinal image were accomplished by the photographer’s use of a laptop computer. Two photographic fields were taken of each eye, the first centered on the optic disc and the second centered on the fovea (Figure). The 45° image was minified x0.64 (at 0 diopters) compared with that taken with a standard 30° camera (Zeiss FF4; Carl Zeiss, Inc, Jena, Germany) (Figure). The iris color was determined by direct observation and was recorded as gray/blue, yellow/green, or tan/brown. The presence of any corneal or lens opacity was recorded. The photographer recorded the lengths of time necessary for pupil dilation and fundus photography.



View larger version (44K):
[in this window]
[in a new window]
Figure. A, Comparison of photographic fields. Photograph of right eye of Diabetic Retinopathy Study standard field 2 taken with 30° film camera. B, Similar standard field 2 taken with the 45° nonmydriatic digital camera. A standard grading grid is centered on the fovea.


One drop of 2.5% phenylephrine hydrochloride and 1 drop of 1% tropicamide were then instilled in the cul-de-sac of each eye to obtain dilation. The size of the dilated pupil was estimated. Two images of the same retinal fields, as described previously, were taken with the nonmydriatic digital camera through the pharmacologically dilated pupil.

Stereoscopic retinal photographs were taken with a standard 30° fundus camera (Zeiss FF4) centered on the disc (Diabetic Retinopathy Study11 standard field 1) and macula (standard field 2), and a nonstereoscopic color fundus photograph was taken temporal to but including the fovea of each eye.12-13 The times at the beginning and end of photography were recorded. Subjects were asked to evaluate their comfort with the flash of each camera on a 10-step scale ranging from 1 (no discomfort) to 10 (extremely uncomfortable) after each set of photographs. At the end of the photography session, participants were asked the following question: "Which is least tolerable: having your pupils dilated, the flash, both the same, or both tolerable?"

GRADING

The digital images were graded using the standard AMD protocol. Graders were masked with respect to information about the subject. Digital images of both eyes were graded by the same grader; the right and left eyes from the same photography session of each participant were both displayed to the grader. Graders were asked to judge field definition, focus of the photographs, pupil size, and the appearance of artifacts prior to determining AMD severity level. Each image was graded twice (a preliminary and a detail grade) online using the Multi-Ethnic Study of Atherosclerosis protocol,14 a modification of the Wisconsin Age-Related Maculopathy Grading System.13 Every digitized image was graded twice by the same grader for the preliminary grading. For the first grading, there was no image manipulation except magnification (no contrast enhancement, lightening, or red-free images). For the second grading, the full complement of image enhancement tools was available.

If the preliminary and detail gradings agreed, the grading was considered final. If there was disagreement between gradings for a lesion, the image was sent to an edit grader for reevaluation of that lesion without knowing what the specific disagreement was. The preliminary, detail, and edit gradings were compared again for agreement. If the edit grading agreed with either the preliminary or detail grading, that one was considered final. If a disagreement remained, the grading of the image was adjudicated by the Reading Center codirector (R.K.). Nine different graders were assigned to perform either preliminary, detail, or edit gradings for each image. No grader saw the same eye twice.

All stereoscopic photographs taken with the film-based 30° camera used color 35-mm slide film (Ektachrome 100 Plus Professional; Kodak, Rochester, NY), which was processed and returned as 2 x 2-in slides. The slides were mounted in clear plastic mounting sheets and graded using a light box and a Donaldson stereo viewer with original magnification x5. Two gradings for AMD were performed for each eye.12 First, a preliminary masked grading was done by one senior grader for drusen size, type, and area; pigmentary abnormalities; geographic atrophy; and exudative lesions. Next, detailed gradings were performed by other experienced graders. For detailed grading, each eye was graded independently of the fellow eye. The assessment consisted of a subfield-by-subfield, lesion-by-lesion evaluation of each photograph set using the Wisconsin Age-Related Maculopathy Grading System.13, 15 Then a series of edits and reviews was performed similar to that done in the digital grading. The presence and severity of specific lesions (eg, maximum drusen size, type, and area and pigmentary abnormalities), as determined by detailed grading, were compared with those of the preliminary grading. Standardized edit rules were used to adjudicate disagreements.13, 15

DEFINITIONS

Early AMD was defined as the presence of soft indistinct drusen only or either hard or soft drusen and pigmentary abnormalities (increased retinal pigment or retinal pigment epithelial [RPE] depigmentation) in the absence of signs of geographic atrophy or exudative lesions. Late AMD was defined as the presence of either geographic atrophy or signs of exudative macular degeneration.

STATISTICAL ANALYSIS

Differences between means were tested for statistical significance using the t test or, in the case of more than 2 groups, analysis of variance. Agreement between grading methods was evaluated with the {kappa} statistic.16-17


RESULTS
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Author information
 •References

The 62 participants ranged in age from 30 to 90 years; the median age was 64 years. Twenty-six (45%) of 58 had a history of cataract, and 10 (17%) of 58 had a history of cataract surgery. Of the 116 irises, 68 (59%) were judged to be gray/blue, 14 (12%) yellow/green, and 34 (29%) tan/brown. We photographed 101 eyes through dark-adapted and pharmacologically dilated pupils using the digital camera and through pharmacologically dilated pupils with the film camera. Twenty-three eyes were not graded because of non-AMD processes (such as pigmentary dystrophies) or photocoagulation scars. There was no significant difference regarding participants’ ability to tolerate the different types of photography (data not shown).

Table 1 lists comparisons of AMD severity by grading of manipulated images taken with a nonmydriatic 45° digital camera through both dark-adapted and pharmacologically dilated pupils as well as stereoscopic film images taken through pharmacologically dilated pupils. When categorizing AMD as none, early, or late, agreement was better between digital and film images taken through pharmacologically dilated than dark-adapted pupils (P = .03). Without pharmacological dilation, more digital than film images were ungradable for AMD severity level. Exact agreement between digital images of dark-adapted eyes and those taken after pharmacological dilation for AMD severity level was 86.1% ({kappa} = 0.78; SE = 0.05) (Table 1).


View this table:
[in this window]
[in a new window]
Table 1. Comparison of Severity of Age-Related Macular Degeneration by Gradings of Photographs Taken With a Nonmydriatic Digital 45° Camera and Standard 30° Film Camera*


Exact agreement for specific AMD lesions was high with moderate to almost perfect {kappa} scores (Table 2). When disagreements were present for specific AMD lesions, drusen 125 µm in diameter or greater were more likely to be graded as present (10.9% vs 2.0%) and increased retinal pigment (3.0% vs 5.0%), RPE depigmentation (1.0% vs 5.0%), and RPE detachment (1.0% vs 5.9%) were less likely to be graded as present in manipulated digital images of dark-adapted pupils compared with film images of pharmacologically dilated pupils. Drusen 125 µm in diameter or greater were more likely to be graded as present (5.9% vs 2.0%) but RPE depigmentation (4.0% vs 5.9%) and RPE detachment (2.0% vs 5.9%) were less likely to be graded as present in manipulated digital images compared with film images of pharmacologically dilated pupils.


View this table:
[in this window]
[in a new window]
Table 2. Percentage of Eyes With Agreement Between Gradings and Specific Lesions Caused by Age-Related Macular Degeneration*


The mean ± SD score on the comfort scale varied from 2.4 ± 0.8 (1 being the most comfortable and 10 the least comfortable) for digital photography through dark-adapted pupils to 2.5 ± 2.0 for digital photography and 3.9 ± 2.6 for film-based photography through pharmacologically dilated pupils. The differences among these means were statistically significant (P<.001). Persons with brown or green eyes were more likely to give higher scores for discomfort (P = .01) than gray- or blue-eyed persons. There was no effect of age or pupil size on comfort with digital or film photography (data not shown).


COMMENT
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Author information
 •References

Our study demonstrated some of the strengths and limitations of both the nonmydriatic digital 45° camera and the standard 30° film-based camera. The advantages of the nonmydriatic digital 45° camera in contrast to the standard 30° film-based camera were that it (1) was less expensive; (2) took a shorter time to learn to use; (3) provided excellent resolution and images that could be magnified and further manipulated (eg, use of the green channel as well as lightening or darkening the image to bring out the presence of a lesion); (4) provided immediate feedback to the photographer regarding the quality of the photograph and to the participant regarding the presence of abnormalities; and (5) was not necessary to pharmacologically dilate the pupil before taking photographs. The relative disadvantages of the nonmydriatic digital camera were that (1) the resultant image did not have stereopsis; (2) there was a relative decrease in color contrast compared with film in eyes that had very red fundi; and (3) there was a higher frequency of ungradable photographs (especially in the presence of small nonpharmacologically dilated pupils and/or media opacities). Use of the cameras was similar in terms of participant acceptance.

Data from our study show moderate to almost perfect agreement between the digital and film-based cameras for detecting AMD and its lesions. The disagreements for AMD severity level were largely due to 45° digital images that could not be graded or were of poor quality. The nonstereoscopic digital images may have contributed to the grader’s missing retinal abnormalities such as RPE depigmentation that are seen more easily on stereoscopic images. The findings in our study are consistent with another study that compared gradings of stereoscopic digital images and film-based images taken through a pharmacologically dilated pupil.8 In that study, the {kappa} value for the between-technique agreement for stages of AMD severity was approximately 0.76. The lower level of agreement in that study compared with ours may have been because AMD severity levels were based on unedited and unadjudicated gradings of low-resolution (800 x 600 pixels) images, whereas our results were based on edited and adjudicated gradings using higher-resolution images (3072 x 2048 pixels).

In our study, there was a higher frequency of larger (≥125 µm in diameter) soft drusen and a lower frequency of increased retinal pigment and RPE depigmentation on nonmydriatic digital images than film images. These differences were more marked for images taken through dark-adapted than pharmacologically dilated pupils, and they were not found in another study when gradings of stereoscopic digital images were compared with those from stereoscopic film-based images (R. van Leeuwen, MD, PhD, written communication, January 2004). We speculate that a lack of stereoscopic effect may have led to a poorer ability to distinguish the edges of large drusen or detect subtle RPE depigmentation, especially when the contrast was poor. However, this did not greatly affect the agreement between gradings using the 2 photography approaches for detecting AMD severity in our study. The decreased ability to detect pigmentary abnormalities with digital photography was consistent with findings from a recent study examining the agreement between gradings of digitized images that were made from film-based images using the original film slides.18 In that study, agreement was good for detecting RPE depigmentation but poor for detecting increased retinal pigment. This might have resulted from a lack of capturing pigment in scanning the film image. It is also possible that differences in spectral sensitivity between film and digital imaging contribute to this discrepancy.

Digital photography provides the grader with powerful tools to examine poor-quality images. For example, without pharmacological dilation, the small pupil may lead to relatively dark images that might obscure AMD lesions. In some cases, manipulating the brightness in such images provides easier detection of these lesions. We had expected that for AMD lesions, manipulated digital images would be more closely correlated with film images than unmanipulated digital images. However, we did not find this to be the case (R.K., unpublished data, 2004). Caution must be exercised when manipulating digital images to avoid the introduction of artifacts that might result in false-positive or false-negative results. For this reason, we have developed protocols that specify allowable manipulations of magnification, contrast, and brightness as well as use of specific color channels with the digital images. The findings from the manipulated images must be seen on the original unmanipulated images for the lesions to be graded as present.

The appropriateness of using the digital nonmydriatic camera in epidemiological studies of AMD depends on the objectives of the specific study. When feasible, stereoscopic fundus photography taken with a digital or film camera through pharmacologically dilated pupils is the preferred approach for detecting AMD. If possible, an ongoing epidemiological study or clinical trial should not change from film to digital capture of retinal images. However, if AMD is not the primary endpoint in a new study and pharmacological dilation of the pupils is not feasible, digital photography using a nonmydriatic camera should provide an alternative to stereoscopic fundus film photography. Furthermore, the nonmydriatic digital camera offers a distinct advantage compared with the nonmydriatic film camera because it enables the photographer to take another image of the retina when the first image is poor or ungradable owing to blinking or other artifacts. Because of its lower flash intensity, the nonmydriatic digital camera allows photography of 2 or more fields of both eyes in a relatively short time compared with the nonmydriatic film camera.

In summary, data from our study show moderate to almost perfect agreement between gradings of AMD severity from digital and film-based images. The use of digital photography in epidemiological studies has resulted in the development of new protocols and software for the capture, transmission, and reading of digital images. New software has enabled application of the Wisconsin Age-Related Maculopathy Grading System currently used in grading film images. Further standardization and development of guidelines for using, taking, and grading digital images are necessary to allow comparisons of results among different systems. This will be especially important in multicenter studies using different digital cameras and software to capture images.


AUTHOR INFORMATION
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Author information
 •References

Correspondence: Ronald Klein, MD, MPH, Department of Ophthalmology and Visual Sciences, University of Wisconsin–Madison, 610 N Walnut St, 460 WARF, Madison, WI 53726 (kleinr{at}epi.ophth.wisc.edu). Reprints are not available from the author.

Submitted for publication: March 18, 2004; final revision received July 15, 2004; accepted July 26, 2004.

Funding/Support: This study was supported by grants EY 06594 and HL 69979 (Drs R. Klein and B. E. K. Klein) from the National Institutes of Health, Bethesda, Md.

Acknowledgment: We thank Canon USA Inc (Lake Success, NY) for providing the digital CR6-45NM nonmydriatic retinal camera and the University of Wisconsin Department of Ophthalmology and Visual Sciences Retina Service for their help in identifying participants in the study.

Financial Disclosure: None.

Author Affiliations: Department of Ophthalmology and Visual Sciences, University of Wisconsin, Madison.


REFERENCES
 Jump to Section
 •Top
 •Introduction
 •Methods
 •Results
 •Comment
 •Author information
 •References

1. Klein R, Wang Q, Klein BEK, Moss SE, Meuer SM. The relationship of age-related maculopathy, cataract, and glaucoma to visual acuity. Invest Ophthalmol Vis Sci. 1995;36:182-191. FREE FULL TEXT
2. Tielsch JM. Vision Problems in the US: A Report on Blindness and Vision Impairment in Adults Age 40 and Older. Schaumburg, Ill: Prevent Blindness America; 1995:1-20.
3. Gass JD. Drusen and disciform macular detachment and degeneration. Arch Ophthalmol. 1973;90:206-217. ISI | PUBMED
4. Klein R, Klein BE, Linton KL. Prevalence of age-related maculopathy: the Beaver Dam Eye Study. Ophthalmology. 1992;99:933-943. ISI | PUBMED
5. Klein R, Rowland ML, Harris MI. Racial/ethnic differences in age-related maculopathy: Third National Health and Nutrition Survey. Ophthalmology. 1995;102:371-381. ISI | PUBMED
6. Klein R, Clegg L, Cooper LS, et al. Prevalence of age-related maculopathy in the Atherosclerosis Risk in Communities Study. Arch Ophthalmol. 1999;117:1203-1210. FREE FULL TEXT
7. Klein R, Klein BE, Marino EK, et al. Early age-related maculopathy in the Cardiovascular Health Study. Ophthalmology. 2003;110:25-33. FULL TEXT | ISI | PUBMED
8. van Leeuwen R, Chakravarthy U, Vingerling JR, et al. Grading of age-related maculopathy for epidemiological studies: is digital imaging as good as 35-mm film? Ophthalmology. 2003;110:1540-1544. FULL TEXT | ISI | PUBMED
9. Bild DE, Bluemke DA, Burke GL, et al. Multi-Ethnic Study of Atherosclerosis: objectives and design. Am J Epidemiol. 2002;156:871-881. FREE FULL TEXT
10. Yannuzzi LA, Ober MD, Slakter JS, et al. Ophthalmic fundus imaging: today and beyond. Am J Ophthalmol. 2004;137:511-524. FULL TEXT | ISI | PUBMED
11. Diabetic Retinopathy Study Coordinating Center. Diabetic Retinopathy Study: Manual of Operations. Baltimore, Md: Diabetic Retinopathy Study Coordinating Center; 1972.
12. Klein R, Klein BE, Jensen SC, Meuer SM. The five-year incidence and progression of age-related maculopathy: the Beaver Dam Eye Study. Ophthalmology. 1997;104:7-21. ISI | PUBMED
13. Klein R, Davis MD, Magli YL, Segal P, Klein BE, Hubbard L. The Wisconsin Age-Related Maculopathy Grading System. Ophthalmology. 1991;98:1128-1134. ISI | PUBMED
14. Multi-Ethnic Study of Atherosclerosis (MESA) information for researchers. MESA protocol. Available at: http://www.mesa-nhlbi.org/researchers.aspx. Accessed February 5, 2004.
15. Klein R, Klein BE. Beaver Dam Eye Study II: Manual of Operations. Springfield, Va: US Department of Commerce; 1995. NTIS Accession No. PB 95-273827.
16. Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977;33:159-174. FULL TEXT | ISI | PUBMED
17. SAS Institute Inc. SAT/STAT User’s Guide, Version 8. Vol 2. Cary, NC: SAS Institute Inc; 1999:1247-1361.
18. Scholl HP, Dandekar SS, Peto T, et al. What is lost by digitizing stereoscopic fundus color slides for macular grading in age-related maculopathy and degeneration? Ophthalmology. 2004;111:125-132. FULL TEXT | ISI | PUBMED


THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

Racial difference in the prevalence of epiretinal membrane between Caucasians and Asians
Kawasaki et al.
Br. J. Ophthalmol. 2008;92:1320-1324.
ABSTRACT | FULL TEXT  

Brightness, Contrast, and Color Balance of Digital versus Film Retinal Images in the Age-Related Eye Disease Study 2
Hubbard et al.
IOVS 2008;49:3269-3282.
ABSTRACT | FULL TEXT  

Prevalence and Associated Risk Factors of Age-Related Macular Degeneration in an Elderly Chinese Population in Taiwan: The Shihpai Eye Study
Chen et al.
IOVS 2008;49:3126-3133.
ABSTRACT | FULL TEXT  

Association Between Vitamin D and Age-Related Macular Degeneration in the Third National Health and Nutrition Examination Survey, 1988 Through 1994
Parekh et al.
Arch Ophthalmol 2007;125:661-669.
ABSTRACT | FULL TEXT  

Subclinical Atherosclerotic Cardiovascular Disease and Early Age-Related Macular Degeneration in a Multiracial Cohort: The Multiethnic Study of Atherosclerosis
Klein et al.
Arch Ophthalmol 2007;125:534-543.
ABSTRACT | FULL TEXT  

Detection of Retinal Pigment Epithelial Changes by Nonmydriatic Fundus Cameras
Salti
Arch Ophthalmol 2005;123:1615-1615.
FULL TEXT  

Detecting Age-Related Macular Degeneration: Technologies Are Best Compared When Standardized
Khouri et al.
Arch Ophthalmol 2005;123:1157-1157.
FULL TEXT  





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 2004 American Medical Association. All Rights Reserved.