  Vol. 116 No. 10, October 1998 TABLE OF CONTENTS
  Archives
  •  Online Features
  Clinical Sciences
 This Article
 •Abstract
 •PDF
 • Reply to article
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on HighWire
 •Citing articles on Web of Science (30)
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Topic Collections
 •Glaucoma
 •Ophthalmological Disorders, Other
 •Alert me on articles by topic
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati Add to Twitter What's this?

Short-Wavelength Automated Perimetry and Retinal Nerve Fiber Layer Evaluation in Suspected Cases of Glaucoma

Vicente Polo, MD; Emilio Abecia, MD; Luis E. Pablo, MD; Isabel Pinilla, MD; Jose M. Larrosa, MD; Francisco M. Honrubia, MD

Arch Ophthalmol. 1998;116:1295-1298.

ABSTRACT

Objectives  To determine if short-wavelength automated perimetry (SWAP) provides evidence that indicates early functional losses in ocular hypertensive subjects and to establish a direct comparison with early structural abnormalities in the retinal nerve fiber layer (RNFL).

Methods  A total of 160 eyes belonging to 83 patients with ocular hypertension (intraocular pressure >21 mm Hg and normal results on standard automated perimetry evaluation), on which a SWAP and RNFL study were performed, were examined. One hundred twenty-eight age-matched subjects without ocular hypertension were evaluated to establish the 95% and 99% confidence intervals at each of the 76 exploration points of the SWAP test.

Results  The RNFL study results were normal in 83 cases (51.8%) and pathologic in 77 cases (48.1%). The SWAP results were pathologic in 57 cases (35.6%). Significant differences (P<.001) were observed when comparing the distribution of normal and pathologic SWAP results among the types of defects in the RNFL (focal wedge, diffuse atrophy, and mixed atrophy).

Conclusions  Short-wavelength automated perimetry is a useful test for the early detection of visual field losses. It is more sensitive than standard automated perimetry and provides a high association with RNFL assessment, which has proved capable of detecting signs of glaucomatous damage several years before the onset of the typical visual field defects.



INTRODUCTION
 Jump to Section
 •Top
 •Introduction
 •Patients and methods
 •Results
 •Comment
 •Author information
 •References

CURRENTLY, the main objective in glaucoma diagnosis is to detect changes in visual function at early stages of the disease. Therefore, treatment will be initiated before the characteristic changes in the optic nerve or in the visual field appear.1

With this aim, several methods have been designed to evaluate the earlier structural and functional abnormalities in glaucoma. But so far, only retinal nerve fiber layer (RNFL) abnormalities and neuroretinal rim changes, measured through longitudinal studies,2-3 have proved capable of detecting the presence and progression of the glaucomatous damage.

In recent years, a new perimetric test—short-wavelength automated perimetry (SWAP)—has been developed and appears to be superior than standard automated perimetry in the detection of visual field defects in patients suspected of having glaucoma, thus becoming an early indicator of functional glaucomatous losses.4-6

The aims of this study were to determine if SWAP provides evidence that suggests early functional losses in patients with ocular hypertension and to establish a direct comparison with structural abnormalities in the RNFL assessment.


PATIENTS AND METHODS
 Jump to Section
 •Top
 •Introduction
 •Patients and methods
 •Results
 •Comment
 •Author information
 •References

PATIENT SELECTION

All patients were recruited prospectively from the Glaucoma Department, Department of Ophthalmology, Hospital Miguel Servet, Zaragoza, Spain. The age range for all patients was from 30 to 60 years, with 23 subjects between the ages of 30 and 39 years, 29 subjects between the ages of 40 and 49 years, and 31 subjects between the ages of 50 and 60 years.

Ocular hypertension was defined as best corrected visual acuity of 20/30 or higher in each eye; intraocular pressure greater than 21 mm Hg on at least 2 occasions (measured by applanation tonometry); refractive errors of less than 5-diopter spherical and 3.00-diopter cylindrical equivalent; normal result on standard achromatic automated perimetry examination (central threshold test; Goldmann size III (4 mm2; white color; stimulus duration, 0.2 seconds; background, 31.5 apostilbs [3.15 millilambert]; STATPAC [statistical package]; Humphrey Instruments, San Leandro, Calif); and normal appearance of the optic nerve head.

Informed consent was obtained from all patients. The nature and possible consequences of the procedures were fully explained to them.

Exclusion criteria were personal history of ocular disease, surgery, or trauma; any media opacities; systemic disease with ophthalmic repercussions; inability to perform any of the tests included in the exploratory procedure (RNFL imaging or SWAP); and low quality of the RNFL images.

EXPLORATORY PROCEDURE

All patients underwent the following protocol: SWAP was performed with a modified Humphrey field analyzer, series I, using the program 30-2 test procedure, which measures the differential light sensitivity at 76 points in the central 30° field. The modifications needed to perform the test are included in the Humphrey field analyzer by the manufacturer. The test uses a bright yellow background of 100 candela per square meter (Shott OG-530 filter, Ealing, Electro-Optical Inc, Holliston, Mass), blue stimuli (440 nm), a Goldmann size V stimulus (Haag-Streit, Bern, Switzerland), and a dynamic range of 0 to 36 dB.7 This program performs increment threshold determinations at 76 locations within the central 30° radius of the visual field.

The index of lens density for each eye was determined using a previously described8 and validated procedure that requires measurement of dark-adapted scotopic thresholds for 450- and 656-nm stimuli obtained with a Tubinger perimeter (Oculus Optikgerate, Dutenhofen, Germany). The Van Norren and Vos procedure9 was used to calculate the ocular media absorption transmission loss that establishes the spectral transmission curve of the ocular media of a "standard subject." These ocular media transmission values were used to correct the SWAP perimetry results for each eye to separate optical from neuronal short-wavelength sensitivity losses.

The photographic evaluation, using a monochromatic red-free RNFL study,10 was performed by 2 of us (J.M.L. and F.M.H.) in random order in a completely masked fashion with optic discs covered and no clinical information available.

In 95% (152/160) of the cases, an agreement was achieved in the RNFL evaluation between both observers. When discrepancies occurred, the photographs were re-evaluated and the criteria of one of us (F.M.H.) prevailed.

ABNORMALITY CRITERIA

Short-Wavelength Automated Perimetry

To establish normative values for the SWAP test, we evaluated 1 eye of 128 normal control subjects, ranging in age from 30 to 60 years. Control subjects met the same inclusion criteria as the patients with ocular hypertension, except for intraocular pressure, which had to be less than 21 mm Hg. For each age decade, confidence intervals of 95% and 99% were established at each of the 76 exploration points of the visual field.11-12 The SWAP data were corrected by ocular media transmission losses measured for each eye. The criteria used to establish an abnormal perimetry result consisted of deficits that produced a cluster of 3 or more points that were lower than the normal 5% probability level or a cluster of 2 or more points that were lower than the normal 1% probability level. These points should not be located along the periphery of the 30° visual field (24 points excluded), or in the blind spot poles (2 points excluded).

Retinal Nerve Fiber Layer

Photographic image evaluations of the RNFL were considered as normal or abnormal. Glaucomatous damage was defined by the presence of focal wedge defects or diffuse or mixed atrophies.


RESULTS
 Jump to Section
 •Top
 •Introduction
 •Patients and methods
 •Results
 •Comment
 •Author information
 •References

A total of 160 eyes of 83 patients were included in this study (46 men and 37 women). Mean age (±SD) was 45.4 (±7.51) years; mean visual acuity was 20/25; and mean intraocular pressure was 23.72 (±2.23) mm Hg.

In the RNFL study of the 160 eyes with ocular hypertension, the fiber assessment was distributed in the following way: focal wedge defects occurred in 13.8% (22 cases); diffuse atrophy in 26.2% (42 cases); mixed atrophy in 8.1% (13 cases); and a normal RNFL in 51.9% (83 cases) (Figure 1). Thus, 51.9% (83 cases) were considered normal results and 42.2% (77 cases) pathologic results.



View larger version (12K):
[in this window]
[in a new window]
Figure 1. Distribution of the different fiber patterns revealed during retinal nerve fiber layer evaluation.


Based on the perimetric criteria described, the SWAP results were pathologic in 57 cases, which represents 35.6% of the total sample.

Figure 2 summarizes the distribution of the different RNFL types related to the perimetric results in the study group. Significant differences were observed comparing the distribution of normal and pathologic perimetric study results among the types of defects in the RNFL (P<.001 by {chi}2 test). When the perimetric result was defined as normal, 74 (71.8%) of 103 eyes had fibers that were normal. On the other hand, the pathologic fields were mainly in 48 (84%) of 57 eyes with RNFL defects.



View larger version (20K):
[in this window]
[in a new window]
Figure 2. Distribution of the different retinal nerve fiber layer (RNFL) types related to the short-wavelength automated perimetry (SWAP) results (P<.001).


Table 1 summarizes the distribution of the SWAP results depending on the type of RNFL defect recorded. The percentage of abnormal visual field results was higher in the groups with RNFL defects than in the groups with normal RNFLs. There were statistically significant differences between the pathologic SWAP perimetric study results in the group with normal RNFLs and each of the different groups with abnormal RNFLs (P<.05 by {chi}2 test).


View this table:
[in this window]
[in a new window]
Table 1. Distribution of the Short-Wavelength Automated Perimetry (SWAP) Results by Retinal Nerve Fiber Layer (RNFL) Type


The comparison between SWAP and RNFL results, classified as normal or altered, also resulted in statistically significant association (P<.001 by {chi}2 test) (Table 2). Using the RNFL as early glaucoma criteria, SWAP sensitivity and specificity values were 62% and 89%, respectively.


View this table:
[in this window]
[in a new window]
Table 2. Distribution of Retinal Nerve Fiber Layer (RNFL) Types and Short-wavelength Automated Perimetry (SWAP) Results*


Figure 3 shows an example of an ocular hypertensive eye that had a RNFL defect and the corresponding SWAP visual field.



View larger version (97K):
[in this window]
[in a new window]
Figure 3. Left eye of a 53-year-old man with ocular hypertension included in the study. Retinal nerve fiber layer photograph (top) of the upper retina, just above the optic disc, with wedge atrophy defined by a dark loss of striations flanked on either side by a mild diffuse atrophy (mixed atrophy). Corresponding short-wavelength automated perimetry visual field analysis (bottom) with an inferior visual field defect of sensitivity loss. The triangle signifies the blind spot.



COMMENT
 Jump to Section
 •Top
 •Introduction
 •Patients and methods
 •Results
 •Comment
 •Author information
 •References

Short-wavelength automated perimetry is a perimetric test designed to isolate and quantify the activity of short-wavelength–sensitive pathways.5-6,8, 11

As can be seen from the results of our study, 57 (35.6%) of 160 pathologic SWAP results were observed in the sample of patients with ocular hypertension and normal standard automated perimetry results. These results are in agreement with those reported by Sample and Weinreb13 who found, using similar technical perimetric parameters, that 43% of their population of patients suspected of having glaucoma had pathologic perimetric results (SWAP results). Likewise, other authors4-5,14-16 have also found short-wavelength sensitivity losses in patients with ocular hypertension, which confirms the usefulness of this test in the assessment of early functional glaucomatous damage.

Retinal nerve fiber layer evaluation is a technique with high sensitivity and specificity in the early diagnosis of glaucomatous damage.17 By means of this technique, the presence of signs of glaucomatous damage is discovered several years before the development of reproducible field abnormalities on standard automated perimetry. At present, there is no study in the literature in which the structural alterations observed in the RNFL are compared with the functional losses found by using SWAP in a group of subjects suspected of having glaucoma.

In our study, the RNFL was normal in 83 eyes (51.9%) and pathologic in 77 (42.2%) (wedge defects, 22; diffuse atrophy, 42; mixed atrophy, 13); these data are similar to the percentages reported by other authors.18 The SWAP distribution in the different groups defined by RNFL imaging confirmed that the greater percentage of pathologic perimetric results was obtained in eyes with an altered RNFL. This association confirmed the validity of the test in detecting functional changes in glaucoma in the early stages of the disease.

It is also interesting to observe the distribution of the different fiber patterns in relation to the type of perimetry, which displays the association that exists between SWAP and RNFL evaluation. The presence of RNFL defects was associated significantly with the higher ratio of eyes with pathologic perimetries.

Similar associations have been discovered between the RNFL condition and the presence of visual field losses in the standard automated perimetry. Abecia et al19 reported a significant association between the severity of the RNFL defects and the defects revealed by standard automated perimetry measurements. A report by Quigley et al20 rating the RNFL, showed a higher incidence of abnormal perimetric results with greater severity of RNFL defects.

The SWAP sensitivity and specificity to identify patients with pathologic RNFLs in our sample were 62% and 89%, respectively. The percentage of perimetric results considered to be pathologic, with a normal RNFL, is sufficiently low (10.8%) to accept the SWAP abnormality criteria in patients suspected of having glaucoma. With regard to sensitivity, we consider 62% sufficient since we are dealing with patients who display RNFL alterations and normal standard automated perimetry results.21

In conclusion, it can be established that SWAP is a useful test in the early detection of incipient losses in the central visual field. Short-wavelength automated perimetry also correlates positively with the RNFL assessment, which has proved capable of detecting signs of glaucomatous damage several years before the appearance of typical central visual field defects in conventional perimetry. Having observed the association between SWAP results and RNFL condition, and in agreement with several longitudinal studies,11, 22-24 there is enough evidence to suggest that SWAP detects functional losses several years before standard automated perimetry.

Nevertheless, a long-term prospective follow-up of these patients will be conducted to study the progression of the SWAP defects found in patients with ocular hypertensioin and to confirm the value of SWAP to predict the future development of visual field losses found by standard automated perimetry.


AUTHOR INFORMATION
 Jump to Section
 •Top
 •Introduction
 •Patients and methods
 •Results
 •Comment
 •Author information
 •References

Accepted for publication April 3, 1998.

Reprints: Vicente Polo, MD, Department of Ophthalmology, Hospital Miguel Servet, Paseo Isabel La Catolica 1 y 3, 50009 Zaragoza, Spain (e-mail: vpolo{at}mx2.redestb.es).

From the Department of Ophthalmology, Hospital Miguel Servet, Zaragoza, Spain.


REFERENCES
 Jump to Section
 •Top
 •Introduction
 •Patients and methods
 •Results
 •Comment
 •Author information
 •References

1. Tielsch JM. Screening for primary open-angle glaucoma: alternative strategies and future directions. J Glaucoma. 1992;1:214-218.
2. Sommer A, Katz J, Quigley HA. Clinically detectable nerve fiber layer atrophy precedes the onset of glaucomatous field loss. Arch Ophthalmol. 1991;109:77-83. FREE FULL TEXT
3. Airaksinen PJ, Tuulonen A, Alanko HL. Rate and pattern of neuroretinal rim area decrease in ocular hypertension and glaucoma. Arch Ophthalmol. 1992;110:206-210. FREE FULL TEXT
4. Heron G, Adams AJ, Husted R. A central visual field for short-wavelength–sensitive pathways in glaucoma and ocular hypertension. Invest Ophthalmol Vis Sci. 1988;29:64-72. FREE FULL TEXT
5. Sample PA, Weinreb RN, Boynton RM. Isolating color vision loss of primary open-angle glaucoma. Am J Ophthalmol. 1988;106:686-691. ISI | PUBMED
6. Johnson CA. Diagnostic value of short-wavelength automated perimetry. Curr Opin Ophthalmol. 1996;7:54-58.
7. Sample PA, Johnson CA, Haegerstrom-Portnoy G, Adams AJ. Optimum parameters for short-wavelength automated perimetry. J Glaucoma. 1996;5:375-383. ISI | PUBMED
8. Polo V, Pinilla I, Abecia E, Larrosa JM, Pablo L, Honrubia FM. Assessment of the ocular media absorption index. Int Ophthalmol. 1996;20:7-9. ISI | PUBMED
9. Van Norren D, Vos JJ. Spectral transmission of the human ocular media. Vision Res. 1974;14:1237-1244. FULL TEXT | ISI | PUBMED
10. Honrubia FM, Calonge B. Evaluation of the nerve fiber layer and peripapillary atrophy in ocular hypertension. Int Ophthalmol. 1991;13:57-62.
11. Johnson CA, Adams AJ, Casson EJ, Brandt JD. Blue-on-yellow perimetry can predict the development of glaucomatous visual field loss. Arch Ophthalmol. 1993;111:645-650. FREE FULL TEXT
12. Moss ID, Wild JM, Whitaker DJ, O'Neill EC. The statistical interpretation of blue-on-yellow visual field loss. Invest Ophthalmol Vis Sci. 1995;36:1398-1410. FREE FULL TEXT
13. Sample PA, Weinreb RN. Color perimetry for assessment of primary open-angle glaucoma. Invest Ophthalmol Vis Sci. 1990;31:1869-1875. FREE FULL TEXT
14. Sample PA, Weinreb RN. Progressive color visual field loss in glaucoma. Invest Ophthalmol Vis Sci. 1992;33:2068-2071. FREE FULL TEXT
15. Johnson CA, Brandt JD, Khong AM, Adams AJ. Short-wavelength automated perimetry in low-, medium-, and high-risk ocular hypertensive eyes: initial baseline results. Arch Ophthalmol. 1995;113:70-76. FREE FULL TEXT
16. Sample PA, Bosworth CF, Weinreb RN. Short-wavelength automated perimetry and motion automated perimetry in patients with glaucoma. Arch Ophthalmol. 1997;115:1129-1133. FREE FULL TEXT
17. Abecia E, Pinilla I, Sanchez A, et al. Valor diagnóstico de la exploración de los elementos nerviosos del ojo en el paciente sospechoso de padecer glaucoma. Arch Soc Esp Oftalmol. 1996;70:489-496.
18. Tuulonen A, Airaksinen PJ. Initial glaucomatous optic disc and retinal nerve fiber layer abnormalities and their progression. Am J Ophthalmol. 1991;111:485-490. ISI | PUBMED
19. Abecia E, Pinilla I, Gómez ML, Pablo LE, Honrubia FM. Early changes in ocular hypertensive eyes (automated perimetry and retinal nerve fiber layer). Ann Ophthalmol. 1995;27:203-208. ISI
20. Quigley HA, Reacher M, Katz J, Strahlman E. Quantitative grading of nerve fiber layer photographs. Ophthalmology. 1993;100:1800-1807. ISI | PUBMED
21. Gonzalez I, Pablo LE, Pueyo M, et al. Assessment of retinal nerve fiber layer in early glaucoma diagnosis. Ann Ophthalmol. 1997;29:122-127. ISI
22. Johnson CA, Adams AJ, Casson EJ, Brandt JD. Progression of early glaucomatous visual field loss as detected by blue-on-yellow and standard white-on-white automated perimetry. Arch Ophthalmol. 1993;111:651-656. FREE FULL TEXT
23. Sample PA, Martinez GA, Weinreb RN. Color visual field: a 5-year prospective study in suspect eyes and eyes with open-angle glaucoma. In: Mills RP, ed. Perimetry Update, 1992/1993. New York, NY: Kugler Publications; 1993:467-473.
24. Johnson CA, Adams AJ, Casson EJ. Blue-on-yellow perimetry: a five-year overview. In: Mills RP, ed. Perimetry Update, 1992/1993. New York, NY: Kugler Publications; 1993:459-466.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter     What's this?

THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

Detection of psychophysical and structural injury in eyes with glaucomatous optic neuropathy and normal standard automated perimetry.
Bagga et al.
Arch Ophthalmol 2006;124:169-176.
ABSTRACT | FULL TEXT  

Visual Function-Specific Perimetry for Indirect Comparison of Different Ganglion Cell Populations in Glaucoma
Sample et al.
IOVS 2000;41:1783-1790.
ABSTRACT | FULL TEXT  