Suture Toxicity in the Germfree Guinea Pig
Philip R. B. McMaster, MD;
Samuel B. Aronson, MD;
Thomas E. Moore, Jr., MD
Arch Ophthalmol. 1970;84(6):776-782.
Abstract
Some 10-0 monofilament nylon (Ethilon) (22.1µ diameter), 9-0 and 8-0 silk, and 7-0 collagen sutures were tied to the corneas of germfree guinea pigs to determine the effects of suture toxicity in a controlled environment. Of the sutures tested, 10-0 nylon demonstrated the mildest reaction and 8-0 silk the most severe inflammatory reaction.
Author Affiliations
Bethesda, Md
From the Laboratory of Microbial Immunity, National Institute of Allergy and Infectious Diseases, National Institutes of Health, Bethesda, Md, and the Eye Research Laboratories, Department of Ophthalmology and the Clinical Laboratories, University of California School of Medicine, San Francisco General Hospital (Drs. McMaster, Aronson, and Moore), San Francisco.
Footnotes
Submitted for publication June 3, 1970.
Reprint requests to Laboratory of Microbial Immunity, National Institute of Allergy and Infectious Diseases, National Institutes of Health, Bethesda, Md 20014 (Dr. McMaster).
CiteULike Connotea Del.icio.us Digg Reddit Technorati Twitter
What's this?
THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES
Cornea and Sclera
Lemp
Arch Ophthalmol 1976;94:473-490.
The Role of Indigenous Bacteria in Producing Anterior Ocular Inflammation
McMaster et al.
Arch Ophthalmol 1971;86:443-445.
ABSTRACT
Cornea and Sclera
Laibson
Arch Ophthalmol 1971;85:738-761.
|