You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 84 No. 1, July 1970 TABLE OF CONTENTS
  Archives
  •  Online Features
  ARTICLES
 This Article
 •References
 •Full text PDF
 • Reply to article
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on HighWire
 •Citing articles on Web of Science (29)
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati Add to Twitter What's this?

Studies in Refraction

I. The Precision of Retinoscopy

Aran Safir, MD; Lyon Hyams, MD; John Philpot, PhD; Louis S. Jagerman, MD

Arch Ophthalmol. 1970;84(1):49-61.


Abstract

A clinical study was done to determine how precisely ophthalmologists perform retinoscopy. Ten subjects were examined by five ophthalmologists on two separate occasions. Statistical analysis of the results showed that the physicians' precision was unaffected by patients' sex or type of refractive error; the physicians in general agreed in their estimates of the magnitudes of the refractive errors, but their precision varied significantly; cylinder power was measured more precisely than sphere power; and right eyes were measured more precisely than left eyes. Quantitative estimates are given for the variability of replicate retinoscopic measurements. Suggestions are made for techniques of clinical retinoscopy which may minimize certain errors.



Author Affiliations

New York; New Brunswick, NJ; Arlington, Va

From the Department of Ophthalmology, Mount Sinai School of Medicine, New York (Dr. Safir); Division of Biostatistics, Department of Community Medicine, Rutgers Medical School (Dr. Hyams), and Center for Computer and Information Services, Rutgers, the State University (Dr. Philpot), New Brunswick, NJ; and the Neurological & Sensory Disease Control Program, Public Health Service, Arlington, Va (Dr. Jagerman).


Footnotes

Submitted for publication Dec 29, 1969.

Reprint requests to Department of Ophthalmology, Mount Sinai School of Medicine, Fifth Ave and 100th St, New York 10029 (Dr. Safir).



Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter     What's this?

THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

Plusoptix Vision Screener: the accuracy and repeatability of refractive measurements using a new autorefractor
Dahlmann-Noor et al.
Br J Ophthalmol 2009;93:346-349.
ABSTRACT | FULL TEXT  

Cycloplegic Refractions in Healthy Children Aged 1 Through 48 Months
Mayer et al.
Arch Ophthalmol 2001;119:1625-1628.
ABSTRACT | FULL TEXT  

Reproducibility and accuracy of measurements with a hand held autorefractor in children
Harvey et al.
Br J Ophthalmol 1997;81:941-948.
ABSTRACT | FULL TEXT  

Clinical Evaluation of an Infrared Refracting Instrument
Bizzell et al.
Arch Ophthalmol 1974;92:103-108.
ABSTRACT  

Studies in Refraction: II. Bias and Accuracy of Retinoscopy
Hyams et al.
Arch Ophthalmol 1971;85:33-41.
ABSTRACT  





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 1970 American Medical Association. All Rights Reserved.