You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 127 No. 4, April 2009 TABLE OF CONTENTS
  Archives
  •  Online Features
  Clinical Sciences
 This Article
 •Full text
 •PDF
 • Reply to article
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Contact me when this article is cited
 Related Content
 •Related article
 •Similar articles in this journal
 Topic Collections
 •Cataracts/ Lens
 •Ophthalmological Procedures, Other
 •Alert me on articles by topic
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati Add to Twitter What's this?

In Vitro Sealing of Clear Corneal Cataract Incisions With a Novel Biodendrimer Adhesive

C. Starck Johnson, MD; Michel Wathier, PhD; Mark Grinstaff, PhD; Terry Kim, MD

Arch Ophthalmol. 2009;127(4):430-434.

Objective  To determine if a biodendrimer adhesive will seal a clear corneal cataract incision.

Design  An experimental study in which 2.75-mm clear corneal cataract incisions were made in 8 human donor eyes. The corneas were mounted on an artificial anterior chamber. Leaking pressure was determined in 6 corneas. These corneas were then treated with adhesive and leaking pressure was again measured in 4 of them. India ink was then applied to the 2 remaining treated and the 2 untreated corneas. Chamber pressure was cycled between 100 and 0 mm Hg. Optical coherence tomography was used to visualize the wound dynamics of a ninth cornea treated with adhesive, mounted, and pressure cycled in a similar fashion.

Results  The mean (SD) leaking pressure was 77 (14) mm Hg for the nonsealed wounds and 142 (22) mm Hg for the adhesive-sealed wounds. india ink entered the nonsealed wounds and anterior chamber when the intraocular pressure was cyclically raised and lowered, whereas no india ink entered the adhesive-sealed wounds. The optical coherence tomography–visualized corneal wound did gape under pressure cycling, but the adhesive remained intact and stretched to conform to the wound.

Conclusions  Biodendrimer adhesives may be used to seal cataract wounds to prevent leakage and influx of fluid.


Author Affiliations: Department of Ophthalmology, Duke University School of Medicine, Durham, North Carolina (Drs Johnson and Kim); Departments of Biomedical Engineering and Chemistry, Metcalf Center for Science and Engineering, Boston University, Boston, Massachusetts (Drs Wathier and Grinstaff).



Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter     What's this?

RELATED ARTICLE

Comparison of Sutures and Dendritic Polymer Adhesives for Corneal Laceration Repair in an In Vivo Chicken Model
John P. Berdahl, C. Stark Johnson, Alan D. Proia, Mark W. Grinstaff, and Terry Kim
Arch Ophthalmol. 2009;127(4):442-447.
ABSTRACT | FULL TEXT  






HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 