You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 126 No. 4, April 2008 TABLE OF CONTENTS
  Archives
  •  Online Features
  Clinical Sciences
 This Article
 •Full text
 •PDF
 • Reply to article
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Topic Collections
 •Surgery
 •Surgical Interventions, Other
 •Glaucoma
 •Strabismus
 •Prostheses/ Implants
 •Alert me on articles by topic

Surgical Treatment of Strabismus Secondary to Glaucoma Drainage Device

Alejandra Roizen, MD; Noa Ela-Dalman, MD; Federico G. Velez, MD; Anne L. Coleman, MD, PhD; Arthur L. Rosenbaum, MD

Arch Ophthalmol. 2008;126(4):480-486.

Objective  To describe surgical strategies in a series of patients with diplopia following implantation of a glaucoma drainage device.

Methods  Retrospective review of 9 consecutive patients who underwent strabismus surgery because of strabismus and diplopia after implantation of a glaucoma drainage device.

Results  Seven patients with marked limitation to ocular rotations and incomitant strabismus underwent surgery on the eye with the implant. Two patients with mild limitation to ocular rotations of the involved eye underwent surgery on the contralateral eye. All patients had a large fibrous capsule surrounding the implant plate, adjacent muscles, and sclera. Intraocular pressure was not elevated postoperatively. Postoperative diplopia in the primary position was eliminated in 5 patients and markedly improved in 3 patients.

Conclusions  Strabismus following implantation of a glaucoma drainage device is an uncommon but serious complication. Restoration of ocular alignment is a complex undertaking requiring strabismus and glaucoma surgical expertise. Multiple surgical complications may occur. Surgical intervention may require complete removal of the fibrous capsule surrounding the implant and involved adjacent structures. Size reduction of the implant plate is helpful and did not interfere with postoperative intraocular pressure control in this study. Surgery on the contralateral eye is an option in patients with mild restriction.