Motion Analysis as a Tool for the Evaluation of Oculoplastic Surgical SkillEvaluation of Oculoplastic Surgical Skill
George M. Saleh, MRCSEd, MRCOphth;
Vinod Gauba, MRCOphth;
Dawn Sim, MRCOphth;
Daniel Lindfield, MBBS;
Maedeh Borhani, BSc;
Salim Ghoussayni, PhD
Arch Ophthalmol. 2008;126(2):213-216.
Objective To evaluate motion analysis as a discriminator of ophthalmic plastic surgical skill between surgeons of varying experience.
Methods Thirty subjects were divided into 3 groups based on surgical experience: novice (< 5 performed procedures; n = 10), intermediate (5-100 procedures; n = 10), and expert (> 100 procedures; n = 10). Detailed 3-dimensional motion data from surgeons performing 2 oculoplastic surgical tasks on a wet laboratory skills board were obtained using the Qualisys motion capture system. The first task was a deep 3-1-1 suture. The second was skin closure with a continuous suture. The main outcome measures were time, overall path length, and total number of movements. Kruskal-Wallis analysis was performed to evaluate statistical significance.
Results Highly significant differences were found during the skin closure task between all groups for mean time (P = .002), overall path length (P = .002), and number of movements (P = .001). For the deep stitch, highly significant differences were also found for time (P < .001), path length (P < .001), and number of movements (P < .001).
Conclusions Motion analysis, using this technology, was able to differentiate between surgeons of varying experience performing oculoplastic tasks, thus demonstrating construct validity. This technique may be useful in the objective quantitative measurement of oculoplastic skill, with potential applications for training and research.
Author Affiliations: Frimley Park Hospital (Drs Saleh, Sim, and Lindfield) and Department of Biomedical Engineering, University of Surrey (Dr Ghoussayni and Ms Borhani), Surrey, Moorfields Eye Hospital, London (Drs Saleh and Sim), and St James Hospital, Leeds (Dr Gauba), England.
CiteULike Connotea Del.icio.us Digg Reddit Technorati Twitter
What's this?
THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES
Kinematic Analysis of Surgical Dexterity in Intraocular Surgery
Saleh et al.
Arch Ophthalmol 2009;127:758-762.
ABSTRACT
| FULL TEXT
|