You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 125 No. 10, October 2007 TABLE OF CONTENTS
  Archives
  •  Online Features
  Clinical Sciences
 This Article
 •Full text
 •PDF
 • Reply to article
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citing articles on HighWire
 •Citing articles on Web of Science (4)
 •Contact me when this article is cited
 Related Content
 •Related article
 •Similar articles in this journal
 Topic Collections
 •Glaucoma
 •Diagnosis
 •Alert me on articles by topic
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati Add to Twitter What's this?

Agreement Between Gonioscopy and Ultrasound Biomicroscopy in Detecting Iridotrabecular Apposition

Yaniv Barkana, MD; Syril K. Dorairaj, MD; Yariv Gerber, PhD; Jeffrey M. Liebmann, MD; Robert Ritch, MD

Arch Ophthalmol. 2007;125(10):1331-1335.

Objective  To assess the agreement between findings obtained at dark-room gonioscopy and ultrasound biomicroscopy (UBM) in the diagnosis of iridotrabecular apposition in light and dark conditions.

Methods  We enrolled patients with appositional angle closure at dark-room gonioscopy performed using a 1-mm slitlamp beam that did not cross the pupil. Ultrasound biomicroscopic images were acquired in normal room light and subsequently with all room lights off. Images were evaluated for the presence or absence of iris-cornea contact. The angle opening distance at 500 µm was calculated.

Results  Iridotrabecular apposition in at least 1 angle quadrant was demonstrated in all 18 eyes at dark-room gonioscopy, 17 eyes (94%) at dark-room UBM, and only 10 eyes (56%) at UBM in room light. Of 18 superior angles that were appositionally closed at dark-room gonioscopy, apposition was demonstrated on UBM images in 16 (89%) in a dark room but only 6 (33%) in room light. Angle opening distance was less during dark-room gonioscopy in all but the nasal quadrant.

Conclusion  We found high agreement between gonioscopy and UBM when both are performed in a completely dark room. Our findings support the recommendation that, in routine clinical practice, gonioscopy be performed in a dark room to avoid misdiagnosis of treatable iridotrabecular apposition.


Author Affiliations: Glaucoma Unit, Department of Ophthalmology, Assaf Harofeh Medical Center, Zerifin, Israel (Dr Barkana); Glaucoma Service, Einhorn Clinical Research Center, New York Eye and Ear Infirmary, New York (Drs Dorairaj and Ritch); Department of Epidemiology and Preventive Medicine, Sackler Medical School, Tel Aviv University, Tel Aviv, Israel (Dr Gerber); Department of Ophthalmology, Manhattan Eye, Ear and Throat Hospital, New York, New York (Dr Liebmann); Department of Ophthalmology, New York University Medical Center, New York (Dr Liebmann); and Department of Ophthalmology, New York Medical College, Valhalla (Dr Liebmann).



Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter     What's this?

RELATED ARTICLE

Shedding Light on Gonioscopy
Paul Palmberg
Arch Ophthalmol. 2007;125(10):1417-1418.
EXTRACT | FULL TEXT  


THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

Anatomical Changes of the Anterior Chamber Angle With Anterior-Segment Optical Coherence Tomography
Liu
Arch Ophthalmol 2008;126:1682-1686.
ABSTRACT | FULL TEXT  

Shedding Light on Gonioscopy
Palmberg
Arch Ophthalmol 2007;125:1417-1418.
FULL TEXT  





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 2007 American Medical Association. All Rights Reserved.