You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 123 No. 2, February 2005 TABLE OF CONTENTS
  Archives
  •  Online Features
  Clinical Sciences
 This Article
 •Full text
 •PDF
 • Reply to article
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on HighWire
 •Citing articles on ISI (15)
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Topic Collections
 •Glaucoma
 •Ocular Imaging
 •Articles for Residents
 •Alert me on articles by topic
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati
What's this?

Noncontact Goniometry With Optical Coherence Tomography

Christopher Wirbelauer, MD; Amir Karandish, MD; Heike Häberle, MD; Duy Thoai Pham, MD

Arch Ophthalmol. 2005;123:179-185.

Objective  To assess the value of noncontact goniometry with optical coherence tomography (OCT) compared with current clinical parameters in the evaluation of the anterior chamber angle (ACA).

Design  Prospective observational study of 138 eyes of 109 patients.

Methods  The ACA parameters and angle-opening distance (AOD) were measured with slitlamp-adapted OCT goniometry. The iris and scleral thickness and the iris convexity were assessed with OCT. Both ACA and AOD were compared with the clinical parameters of gonioscopy grade, limbal anterior chamber depth (ACD), ultrasonographic central ACD, and lens-axial length (LAL) ratio.

Results  Noncontact goniometry with OCT revealed mean ± SD values of 28° ± 16° for the ACA and 381 ± 234 µm for the AOD. The mean ± SD iris thickness was 369 ± 84 µm, and the scleral thickness at the scleral spur was 943 ± 148 µm. There was a significant correlation (P<.001) with the clinical parameters of gonioscopic grading, limbal ACD, ultrasonographic central ACD, and LAL ratio. The sensitivity and specificity of OCT goniometry to detect an occludable angle were 86% and 95% for ACA and 85% and 90% for AOD, respectively.

Conclusions  Noncontact goniometry with OCT was helpful in evaluating the anterior chamber structures and as a screening modality. Goniometry with OCT could improve the noninvasive clinical assessment and treatment of patients with glaucoma.


Author Affiliation: Klinik für Augenheilkunde, Vivantes Klinikum Neukölln, Berlin, Germany.



Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati     What's this?

THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

Comparison of Slitlamp Optical Coherence Tomography and Scanning Peripheral Anterior Chamber Depth Analyzer to Evaluate Angle Closure in Asian Eyes
Wong et al.
Arch Ophthalmol 2009;127:599-603.
ABSTRACT | FULL TEXT  

Anterior Chamber Angle Measurement with Anterior Segment Optical Coherence Tomography: A Comparison between Slit Lamp OCT and Visante OCT
Leung et al.
IOVS 2008;49:3469-3474.
ABSTRACT | FULL TEXT  

Dynamic Analysis of Dark Light Changes of the Anterior Chamber Angle with Anterior Segment OCT
Leung et al.
IOVS 2007;48:4116-4122.
ABSTRACT | FULL TEXT  

Reproducibility of Anterior Chamber Angle Measurements Obtained with Anterior Segment Optical Coherence Tomography
Radhakrishnan et al.
IOVS 2007;48:3683-3688.
ABSTRACT | FULL TEXT  





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 2005 American Medical Association. All Rights Reserved.