You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 122 No. 6, June 2004 TABLE OF CONTENTS
  Archives
  •  Online Features
  Clinical Sciences
 This Article
 •Full text
 •PDF
 • Reply to article
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on HighWire
 •Citing articles on ISI (114)
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Topic Collections
 •Radiologic Imaging
 •Glaucoma
 •Ocular Imaging
 •Alert me on articles by topic

Comparison of the GDx VCC Scanning Laser Polarimeter, HRT II Confocal Scanning Laser Ophthalmoscope, and Stratus OCT Optical Coherence Tomograph for the Detection of Glaucoma

Felipe A. Medeiros, MD; Linda M. Zangwill, PhD; Christopher Bowd, PhD; Robert N. Weinreb, MD

Arch Ophthalmol. 2004;122:827-837.

Objective  To compare the abilities of current commercially available versions of 3 optical imaging techniques: scanning laser polarimetry with variable corneal compensation (GDx VCC), confocal scanning laser ophthalmoscopy (HRT II [Heidelberg Retina Tomograph]), and optical coherence tomography (Stratus OCT) to discriminate between healthy eyes and eyes with glaucomatous visual field loss.

Methods  We included 107 patients with glaucomatous visual field loss and 76 healthy subjects of a similar age. All individuals underwent imaging with a GDx VCC, HRT II, and fast retinal nerve fiber layer scan with the Stratus OCT as well as visual field testing within a 6-month period. Receiver operating characteristic curves and sensitivities at fixed specificities (80% and 95%) were calculated for parameters reported as continuous variables. Diagnostic categorization (outside normal limits, borderline, or within normal limits) provided by each instrument after comparison with its respective normative database was also evaluated, and likelihood ratios were reported. Agreement on categorization between methods (weighted {kappa}) was assessed.

Results  After the exclusion of subjects with unacceptable images, the final study sample included 141 eyes of 141 subjects (75 with glaucoma and 66 healthy control subjects). Mean ± SD mean deviation of the visual field test result for patients with glaucoma was –4.87 ± 3.9 dB, and 70% of these patients had early glaucomatous visual field damage. No statistically significant difference was found between the areas under the receiver operating characteristic curves (AUCs) for the best parameters from the GDx VCC (nerve fiber indicator, AUC = 0.91), Stratus OCT (retinal nerve fiber layer inferior thickness, AUC = 0.92), and HRT II (linear discriminant function, AUC = 0.86). Abnormal results for each of the instruments, after comparison with their normative databases, were associated with strong positive likelihood ratios. Chance-corrected agreement (weighted {kappa}) among the 3 instruments ranged from moderate to substantial (0.50-0.72).

Conclusions  The AUCs and the sensitivities at high specificities were similar among the best parameters from each instrument. Abnormal results (as compared with each instrument's normative database) were associated with high likelihood ratios and large effects on posttest probabilities of having glaucomatous visual field loss. Calculation of likelihood ratios may provide additional information to assist the clinician in diagnosing glaucoma with these instruments.


From the Hamilton Glaucoma Center and Department of Ophthalmology, University of California, San Diego. Dr Weinreb receives research support from Carl Zeiss Meditec, Inc (Dublin, Calif), Heidelberg Engineering (Dossenheim, Germany), and Laser Diagnostic Technologies, Inc (San Diego).



THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

Mapping Standard Automated Perimetry to the Peripapillary Retinal Nerve Fiber Layer in Glaucoma
Ferreras et al.
IOVS 2008;49:3018-3025.
ABSTRACT | FULL TEXT  

Logistic Regression Analysis for Early Glaucoma Diagnosis Using Optical Coherence Tomography
Ferreras et al.
Arch Ophthalmol 2008;126:465-470.
ABSTRACT | FULL TEXT  

Practical recommendations for measuring rates of visual field change in glaucoma
Chauhan et al.
Br. J. Ophthalmol. 2008;92:569-573.
ABSTRACT | FULL TEXT  

Impact of Diabetic Retinopathy on Quantitative Retinal Nerve Fiber Layer Measurement and Glaucoma Screening
Takahashi and Chihara
IOVS 2008;49:687-692.
ABSTRACT | FULL TEXT  

Effect of pupillary dilatation on glaucoma assessments using optical coherence tomography
Smith et al.
Br. J. Ophthalmol. 2007;91:1686-1690.
ABSTRACT | FULL TEXT  

Optical coherence tomography and disease subtype in multiple sclerosis
Pulicken et al.
Neurology 2007;69:2085-2092.
ABSTRACT | FULL TEXT  

Detection of Glaucoma Using Scanning Laser Polarimetry with Enhanced Corneal Compensation
Medeiros et al.
IOVS 2007;48:3146-3153.
ABSTRACT | FULL TEXT  

Optical coherence tomography for clinical detection and monitoring of glaucoma?
Bowd
Br. J. Ophthalmol. 2007;91:853-854.
FULL TEXT  

Glaucoma detection with matrix and standard achromatic perimetry
Burgansky-Eliash et al.
Br. J. Ophthalmol. 2007;91:933-938.
ABSTRACT | FULL TEXT  

The Effect of Disc Size and Severity of Disease on the Diagnostic Accuracy of the Heidelberg Retina Tomograph Glaucoma Probability Score
Zangwill et al.
IOVS 2007;48:2653-2660.
ABSTRACT | FULL TEXT  

Scanning Laser Polarimetry with Enhanced Corneal Compensation and Optical Coherence Tomography in Normal and Glaucomatous Eyes
Sehi et al.
IOVS 2007;48:2099-2104.
ABSTRACT | FULL TEXT  

Progressive macular thinning after indirect traumatic optic neuropathy documented by optical coherence tomography
Vessani et al.
Br. J. Ophthalmol. 2007;91:697-698.
FULL TEXT  

Longitudinal Changes in Retinal Nerve Fiber Layer Thickness after Acute Primary Angle Closure Measured with Optical Coherence Tomography
Tsai et al.
IOVS 2007;48:1659-1664.
ABSTRACT | FULL TEXT  

Accuracy of GDx VCC, HRT I, and clinical assessment of stereoscopic optic nerve head photographs for diagnosing glaucoma
Reus et al.
Br. J. Ophthalmol. 2007;91:313-318.
ABSTRACT | FULL TEXT  

Retinotopic Organization of Primary Visual Cortex in Glaucoma: A Method for Comparing Cortical Function with Damage to the Optic Disk
Duncan et al.
IOVS 2007;48:733-744.
ABSTRACT | FULL TEXT  

The Effects of Study Design and Spectrum Bias on the Evaluation of Diagnostic Accuracy of Confocal Scanning Laser Ophthalmoscopy in Glaucoma
Medeiros et al.
IOVS 2007;48:214-222.
ABSTRACT | FULL TEXT  

Retinal Nerve Fiber Layer Measurements in Myopia: An Optical Coherence Tomography Study
Leung et al.
IOVS 2006;47:5171-5176.
ABSTRACT | FULL TEXT  

The ISNT Rule and Differentiation of Normal From Glaucomatous Eyes.
Harizman et al.
Arch Ophthalmol 2006;124:1579-1583.
ABSTRACT | FULL TEXT  

Peripapillary fundus perimetry in eyes with glaucoma
Convento et al.
Br. J. Ophthalmol. 2006;90:1398-1403.
ABSTRACT | FULL TEXT  

Enhanced imaging algorithm for scanning laser polarimetry with variable corneal compensation.
Reus et al.
IOVS 2006;47:3870-3877.
ABSTRACT | FULL TEXT  

Discrimination between Glaucomatous and Nonglaucomatous Eyes Using Quantitative Imaging Devices and Subjective Optic Nerve Head Assessment.
DeLeon-Ortega et al.
IOVS 2006;47:3374-3380.
ABSTRACT | FULL TEXT  

Detection and Quantification of Retinal Nerve Fiber Layer Thickness in Optic Disc Edema Using Stratus OCT.
Savini et al.
Arch Ophthalmol 2006;124:1111-1117.
ABSTRACT | FULL TEXT  

The quality of reporting of diagnostic accuracy studies in glaucoma using the heidelberg retina tomograph.
Shunmugam and Azuara-Blanco
IOVS 2006;47:2317-2323.
ABSTRACT | FULL TEXT  

A statistical approach to the evaluation of covariate effects on the receiver operating characteristic curves of diagnostic tests in glaucoma.
Medeiros et al.
IOVS 2006;47:2520-2527.
ABSTRACT | FULL TEXT  

Diagnostic Capability of Optical Coherence Tomography in Evaluating the Degree of Glaucomatous Retinal Nerve Fiber Damage
Sihota et al.
IOVS 2006;47:2006-2010.
ABSTRACT | FULL TEXT  

Influence of disease severity and optic disc size on the diagnostic performance of imaging instruments in glaucoma.
Medeiros et al.
IOVS 2006;47:1008-1015.
ABSTRACT | FULL TEXT  

Detection of psychophysical and structural injury in eyes with glaucomatous optic neuropathy and normal standard automated perimetry.
Bagga et al.
Arch Ophthalmol 2006;124:169-176.
ABSTRACT | FULL TEXT  

Heritability of Macular Thickness Determined by Optical Coherence Tomography
Chamberlain et al.
IOVS 2006;47:336-340.
ABSTRACT | FULL TEXT  

Development and Comparison of Automated Classifiers for Glaucoma Diagnosis Using Stratus Optical Coherence Tomography
Huang and Chen
IOVS 2005;46:4121-4129.
ABSTRACT | FULL TEXT  

Optical Coherence Tomography Machine Learning Classifiers for Glaucoma Detection: A Preliminary Study
Burgansky-Eliash et al.
IOVS 2005;46:4147-4152.
ABSTRACT | FULL TEXT  

Relationships between Standard Automated Perimetry, HRT Confocal Scanning Laser Ophthalmoscopy, and GDx VCC Scanning Laser Polarimetry
Reus and Lemij
IOVS 2005;46:4182-4188.
ABSTRACT | FULL TEXT  

Comparative Study of Retinal Nerve Fiber Layer Measurement by StratusOCT and GDx VCC, I: Correlation Analysis in Glaucoma
Leung et al.
IOVS 2005;46:3214-3220.
ABSTRACT | FULL TEXT  

Baseline Topographic Optic Disc Measurements Are Associated With the Development of Primary Open-Angle Glaucoma: The Confocal Scanning Laser Ophthalmoscopy Ancillary Study to the Ocular Hypertension Treatment Study
Zangwill et al.
Arch Ophthalmol 2005;123:1188-1197.
ABSTRACT | FULL TEXT  

Enhanced corneal compensation for scanning laser polarimetry on eyes with atypical polarisation pattern
Toth and Hollo
Br. J. Ophthalmol. 2005;89:1139-1142.
ABSTRACT | FULL TEXT  

Comparability of Retinal Nerve Fiber Layer Thickness Measurements of Optical Coherence Tomography Instruments
Bourne et al.
IOVS 2005;46:1280-1285.
ABSTRACT | FULL TEXT  

Relevance Vector Machine and Support Vector Machine Classifier Analysis of Scanning Laser Polarimetry Retinal Nerve Fiber Layer Measurements
Bowd et al.
IOVS 2005;46:1322-1329.
ABSTRACT | FULL TEXT  

Analysis of Retinal Nerve Fiber Layer and Optic Nerve Head in Glaucoma with Different Reference Plane Offsets, Using Optical Coherence Tomography
Leung et al.
IOVS 2005;46:891-899.
ABSTRACT | FULL TEXT  





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 2004 American Medical Association. All Rights Reserved.