You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 121 No. 7, July 2003 TABLE OF CONTENTS
  Archives
  •  Online Features
  Clinical Sciences
 This Article
 •Full text
 •PDF
 • Reply to article
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on HighWire
 •Citing articles on ISI (6)
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Topic Collections
 •Pediatric Ophthalmology
 •Alert me on articles by topic
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati
What's this?

Highly Precise Eye Length Measurements in Children Aged 3 Through 12 Years

Graham E. Quinn, MD, MSCE; Ellie L. Francis, OD, PhD; Karen S. Nipper, MD; D. Ian Flitcroft, MD, PhD; Gui-shuang Ying, MS; Renee C. Rees, PhD; Gregor F. Schmid, PhD; Maureen G. Maguire, PhD; Richard A. Stone, MD

Arch Ophthalmol. 2003;121:985-990.

Objective  To determine the feasibility, reliability, and validity of using partial coherence interferometry, a noncontact method that detects interference patterns from various layers of the eye, to measure axial length in young children.

Methods  The right eye of 64 subjects (mean age, 8.4 y; age range, 3.4-12.9 y; best-corrected visual acuity >=20/30) was measured. Subjects fixated monocularly on the collimated light pattern from a laser diode (the alignment beam) and the operator used a video monitor to align the corneal reflection in the optical path. Axial length was measured during an 0.8-second scan using interference patterns from a collimated short coherence superluminescence diode aligned coaxially with the laser diode. Five series of 16 readings each were obtained. The average axial length for each of the 5 series of readings was calculated.

Main Outcome Measure  Axial length.

Results  Within-subject precision of axial length measurements was high, with an overall SE of measurement of 8 µm for individual subjects across the 5 sessions (95% confidence interval, ±16 µm). Subgroup analysis showed that sex, age, spherical equivalent, and refractive error exerted statistically significant effects on precision, but all of the differences among subgroups were 3 µm or less and likely to be insignificant clinically. Axial length measured by partial coherence interferometry varied systematically, with factors known to influence eye length (ie, age and refractive error), further validating the measurement method.

Conclusion  The partial coherence interferometry technique provides reproducible, extraordinarily precise eye length measurements in young children and should enable novel approaches to study eye growth and refractive development.


From the Division of Pediatric Ophthalmology, The Children's Hospital of Philadelphia, Philadelphia, Pa (Drs Quinn, Francis, Nipper, and Stone); Department of Ophthalmology, Scheie Eye Institute–University of Pennsylvania, Philadelphia (Drs Quinn, Francis, Rees, Maguire, and Stone and Mr Ying); The Children's Hospital, Dublin, Ireland (Dr Flitcroft); and the Pennsylvania College of Optometry, Philadelphia (Dr Schmid). The authors have no proprietary interest in the partial coherence interferometer.



Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati     What's this?

THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

In Vivo Human Choroidal Thickness Measurements: Evidence for Diurnal Fluctuations
Brown et al.
IOVS 2009;50:5-12.
ABSTRACT | FULL TEXT  

The Relation of Axial Length and Intraocular Pressure Fluctuations in Human Eyes
Wilson et al.
IOVS 2006;47:1778-1784.
ABSTRACT | FULL TEXT  

Diurnal Axial Length Fluctuations in Human Eyes
Stone et al.
IOVS 2004;45:63-70.
ABSTRACT | FULL TEXT  





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 2003 American Medical Association. All Rights Reserved.