You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 118 No. 8, August 2000 TABLE OF CONTENTS
  Archives
  •  Online Features
  Laboratory Sciences
 This Article
 •Full text
 •PDF
 • Reply to article
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on HighWire
 •Citing articles on Web of Science (24)
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Topic Collections
 •Glaucoma
 •Prostheses/ Implants
 •Facial Plastic Surgery
 •Biomaterials and Implants
 •Alert me on articles by topic
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati Add to Twitter What's this?

Comparison of Different Biomaterials for Glaucoma Drainage Devices

Part 2

Ramesh S. Ayyala, MD, FRCS, FRCOphth; B. Michelini-Norris, PhD; Ana Flores, MD; Edward Haller; Curtis E. Margo, MD, MPH

Arch Ophthalmol. 2000;118:1081-1084.

Background  Inflammation associated with biomaterials may contribute to the failure of glaucoma drainage devices.

Objective  To compare the inflammatory reaction associated with the insertion of Krupin silicone, Molteno polypropylene, and Acrosof end plates in the subconjunctival space of rabbits.

Methods  Similar-sized glaucoma end plates made of 3 different biomaterials were sutured to the sclera in the superotemporal quadrant of the rabbit eye. Thirty eyes of 15 albino New Zealand rabbits were randomly assigned to the 3 groups. Conjunctival vascular hyperemia was graded in a masked fashion among the 3 groups. At the end of 3 weeks, the enucleated eyes were examined histologically and by scanning electron microscopy.

Results  Molteno polypropylene was associated with more inflammation both in clinical observations and based on histological grading. Silicone and Acrosof were associated with less intense inflammation. One polypropylene end plate was extruded on day 21.

Conclusions  Polypropylene appears to be more inflammatory than silicone. Flexible biomaterials appear to be less inflammatory than rigid ones.

Clinical Relevance  Bleb failure following glaucoma drainage device implantation could be related to the biomaterial-associated inflammation. Choosing a biomaterial with the least inflammatory potential might enhance the success rate of the glaucoma drainage device.


From the Departments of Ophthalmology, Tulane University Medical Center, School of Medicine, New Orleans, La, and Medical Center of Louisiana at New Orleans (Dr Ayyala); Departments of Ophthalmology (Drs Michelini-Norris and Flores) and Pathology (Dr Haller), University of South Florida, Tampa, and Department of Ophthalmology, Watson Clinic, Lakeland, Fla (Dr Margo).



Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter     What's this?

THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

Histological Biocompatibility of a Stainless Steel Miniature Glaucoma Drainage Device in Humans: A Case Report
De Feo et al.
Toxicol Pathol 2009;37:512-516.
ABSTRACT | FULL TEXT  

Comparison of polypropylene and silicone Ahmed valve survival 2 years following implantation in the first 2 years of life
Khan and Al-Mobarak
Br J Ophthalmol 2009;93:791-794.
ABSTRACT | FULL TEXT  

Creation of a Drug-Coated Glaucoma Drainage Device Using Polymer Technology: In Vitro and In Vivo Studies
Sahiner et al.
Arch Ophthalmol 2009;127:448-453.
ABSTRACT | FULL TEXT  

MR Imaging Features of Giant Reservoir Formation in the Orbit: An Unusual Complication of Ahmed Glaucoma Valve Implantation
Jeon et al.
Am. J. Neuroradiol. 2007;28:1565-1566.
ABSTRACT | FULL TEXT  

A Newly Designed Glaucoma Drainage Implant Made of Poly(styrene-b-isobutylene-b-styrene): Biocompatibility and Function in Normal Rabbit Eyes
Acosta et al.
Arch Ophthalmol 2006;124:1742-1749.
ABSTRACT | FULL TEXT  





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 2000 American Medical Association. All Rights Reserved.