You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 117 No. 2, February 1999 TABLE OF CONTENTS
  Archives
  •  Online Features
  Laboratory Sciences
 This Article
 •Full text
 •PDF
 • Reply to article
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on HighWire
 •Citing articles on Web of Science (22)
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Topic Collections
 •Glaucoma
 •Facial Plastic Surgery
 •Biomaterials and Implants
 •Alert me on articles by topic
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati Add to Twitter What's this?

Comparison of Different Biomaterials for Glaucoma Drainage Devices

Ramesh S. Ayyala, MD, FRCS, FRCOphth; Lynn E. Harman, MD; B. Michelini-Norris, PhD; Leo E. Ondrovic, MSES; Edward Haller; Curtis E. Margo, MD, MPH; Scott X. Stevens, MD

Arch Ophthalmol. 1999;117:233-236.

Objectives  To compare the inflammatory reaction associated with the insertion of silicone and polypropylene endplates and endplates made of a new biocompatible polymer, Vivathane, in the rabbit subconjunctival space.

Methods  Similar-sized endplates made of 3 different biomaterials were sutured to the sclera in the superotemporal quadrant of the rabbit eye. Thirty eyes of 15 albino New Zealand rabbits were randomly assigned to the 3 groups. Conjunctival vascular hyperemia was graded in a masked fashion among groups. At the end of 3 weeks, the enucleated eyes were examined histologically and using scanning electron microscopy.

Results  Polypropylene and Vivathane were associated with significantly more inflammation in clinical observations and based on histological grading. Silicone was associated with the least amount of inflammation. Three polypropylene and 1 Vivathane plate were extruded between the second and third week.

Conclusions  Silicone is the most inert of the 3 materials tested. Inflammation associated with biomaterials may contribute to the failure of the glaucoma drainage devices.

Clinical Relevance  Bleb inflammation may be related to the biomaterial being used as the endplate. Endplates should be handled carefully during surgery to avoid creating rough spots.


From the Departments of Ophthalmology (Drs Ayyala, Harman, Michelini-Norris, and Stevens), Surgery (Mr Ondrovic), and Pathology (Mr Haller), University of South Florida, Tampa; and the Department of Ophthalmology, Watson Clinic, Lakeland, Fla (Dr Margo).



Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter     What's this?

THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

Histological Biocompatibility of a Stainless Steel Miniature Glaucoma Drainage Device in Humans: A Case Report
De Feo et al.
Toxicol Pathol 2009;37:512-516.
ABSTRACT | FULL TEXT  

Comparison of polypropylene and silicone Ahmed valve survival 2 years following implantation in the first 2 years of life
Khan and Al-Mobarak
Br J Ophthalmol 2009;93:791-794.
ABSTRACT | FULL TEXT  

Creation of a Drug-Coated Glaucoma Drainage Device Using Polymer Technology: In Vitro and In Vivo Studies
Sahiner et al.
Arch Ophthalmol 2009;127:448-453.
ABSTRACT | FULL TEXT  

Ex-PRESS implant
Mermoud
Br J Ophthalmol 2005;89:396-397.
FULL TEXT  

Comparison of Different Biomaterials for Glaucoma Drainage Devices: Part 2
Ayyala et al.
Arch Ophthalmol 2000;118:1081-1084.
ABSTRACT | FULL TEXT  





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 1999 American Medical Association. All Rights Reserved.