You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 117 No. 1, January 1999 TABLE OF CONTENTS
  Archives
  •  Online Features
  Clinical Sciences
 This Article
 •Full text
 •PDF
 • Reply to article
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on HighWire
 •Citing articles on ISI (143)
 •Contact me when this article is cited
 Related Content
 •Related article
 •Similar articles in this journal
 Topic Collections
 •Glaucoma
 •Ophthalmological Disorders, Other
 •Alert me on articles by topic

Corneal Thickness in Ocular Hypertension, Primary Open-angle Glaucoma, and Normal Tension Glaucoma

René-Pierre Copt, MD; Ravi Thomas, MD; André Mermoud, MD

Arch Ophthalmol. 1999;117:14-16.

Objectives  To determine the effect of central corneal thickness (CCT) on the measurement of intraocular pressure (IOP) and on the resultant reclassification of patients as having primary open-angle glaucoma (POAG), normal tension glaucoma (NTG), or ocular hypertension (OHT).

Methods  Intraocular pressure (Goldmann applanation tonomety) and CCT (ultrasound pachymetry) were measured in 22 patients with NTG, 49 with POAG, 44 with OHT and in 18 control subjects. The CCT was used to obtain a corrected value for the IOP and to reclassify the type of glaucoma.

Results  There was no significant difference in CCT between controls (552±35 µm) and patients with POAG (543±35 µm), but the CCT in the group with NTG (521±31 µm) was significantly lower than that in the control group or the group with POAG (P<.001), and the CCT in the group with OHT (583±34 µm) was significantly higher than in controls or patients with POAG (P<.001). Correcting IOP for corneal thickness, 31% of the patients with NTG could be reclassified as having POAG, and 56% of the patients with OHT as normal.

Conclusions  Patients with NTG have a thinner CCT than do patients with POAG or controls. Underestimation of the IOP in patients with POAG who have thin corneas may lead to a misdiagnosis of NTG, while overestimation of the IOP in normal subjects who have thick corneas may lead to a misdiagnosis of OHT.


From the Hôpital Ophtalmique Jules Gonin, University of Lausanne, Lausanne, Switzerland (Drs Copt and Mermoud); and Schell Eye Hospital, CMC Vellore, India (Dr Thomas).


RELATED ARTICLE

Tonometry and Corneal Thickness
Richard F. Brubaker
Arch Ophthalmol. 1999;117(1):104-105.
EXTRACT | FULL TEXT  


THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

Role of Corneal Elasticity in Damping of Intraocular Pressure
Johnson et al.
IOVS 2007;48:2540-2544.
ABSTRACT | FULL TEXT  

Effect of Central Corneal Thickness on Dynamic Contour Tonometry and Goldmann Applanation Tonometry in Primary Open-angle Glaucoma
Grieshaber et al.
Arch Ophthalmol 2007;125:740-744.
ABSTRACT | FULL TEXT  

Nine-year changes in intraocular pressure: the barbados eye studies.
Wu et al.
Arch Ophthalmol 2006;124:1631-1636.
ABSTRACT | FULL TEXT  

Glaucoma and increased central corneal thickness in aphakic and pseudophakic patients after congenital cataract surgery
Simsek et al.
Br. J. Ophthalmol. 2006;90:1103-1106.
ABSTRACT | FULL TEXT  

Quantitative Correlation of Optic Nerve Pathology with Ocular Pressure and Corneal Thickness in the DBA/2 Mouse Model of Glaucoma.
Inman et al.
IOVS 2006;47:986-996.
ABSTRACT | FULL TEXT  

Clinical Comparison of Contour and Applanation Tonometry and Their Relationship to Pachymetry
Kniestedt et al.
Arch Ophthalmol 2005;123:1532-1537.
ABSTRACT | FULL TEXT  

Underestimate of Tonometric Readings after Photorefractive Keratectomy Increases at Higher Intraocular Pressure Levels
Tamburrelli et al.
IOVS 2005;46:3208-3213.
ABSTRACT | FULL TEXT  

Clinical Features and Course of Patients with Glaucoma with the E50K Mutation in the Optineurin Gene
Aung et al.
IOVS 2005;46:2816-2822.
ABSTRACT | FULL TEXT  

Central Corneal Thickness Correlated with Glaucoma Damage and Rate of Progression
Jonas et al.
IOVS 2005;46:1269-1274.
ABSTRACT | FULL TEXT  

Central Corneal Thickness and Thickness of the Lamina Cribrosa in Human Eyes
Jonas and Holbach
IOVS 2005;46:1275-1279.
ABSTRACT | FULL TEXT  

Clinical Significance of Central Corneal Thickness in the Management of Glaucoma
Shih et al.
Arch Ophthalmol 2004;122:1270-1275.
ABSTRACT | FULL TEXT  

Dynamic Contour Tonometry: A Comparative Study on Human Cadaver Eyes
Kniestedt et al.
Arch Ophthalmol 2004;122:1287-1293.
ABSTRACT | FULL TEXT  

Long term effect of latanoprost on intraocular pressure in normal tension glaucoma
Ang et al.
Br. J. Ophthalmol. 2004;88:630-634.
ABSTRACT | FULL TEXT  

Effect of corneal parameters on measurements using the pulsatile ocular blood flow tonograph and Goldmann applanation tonometer
Gunvant et al.
Br. J. Ophthalmol. 2004;88:518-522.
ABSTRACT | FULL TEXT  

Tonometric Changes of Latanoprost-Induced Intraocular Pressure Reduction after Photorefractive Keratectomy
Tamburrelli et al.
IOVS 2004;45:846-850.
ABSTRACT | FULL TEXT  

Intraobserver and interobserver reproducibility in the evaluation of ultrasonic pachymetry measurements of central corneal thickness
Miglior et al.
Br. J. Ophthalmol. 2004;88:174-177.
ABSTRACT | FULL TEXT  

Central Corneal Thickness as a Risk Factor for Advanced Glaucoma Damage
Herndon et al.
Arch Ophthalmol 2004;122:17-21.
ABSTRACT | FULL TEXT  

Central Corneal Thickness in Latinos
Hahn et al.
IOVS 2003;44:1508-1512.
ABSTRACT | FULL TEXT  

Corneal Thickness and Intraocular Pressure in the Barbados Eye Studies
Nemesure et al.
Arch Ophthalmol 2003;121:240-244.
ABSTRACT | FULL TEXT  

A few remarks about glaucoma
Wegner
Br. J. Ophthalmol. 2002;86:836-837.
FULL TEXT  

The Ocular Hypertension Treatment Study: Baseline Factors That Predict the Onset of Primary Open-Angle Glaucoma
Gordon et al.
Arch Ophthalmol 2002;120:714-720.
ABSTRACT | FULL TEXT  

Effect of Corneal Thickness on Intraocular Pressure Measurements with the Pneumotonometer, Goldmann Applanation Tonometer, and Tono-Pen
Bhan et al.
IOVS 2002;43:1389-1392.
ABSTRACT | FULL TEXT  

Central corneal thickness measurements in patients with normal tension glaucoma, primary open angle glaucoma, pseudoexfoliation glaucoma, or ocular hypertension
Ventura et al.
Br. J. Ophthalmol. 2001;85:792-795.
ABSTRACT | FULL TEXT  

Central Corneal Thickness of Caucasians and African Americans in Glaucomatous and Nonglaucomatous Populations
La Rosa et al.
Arch Ophthalmol 2001;119:23-27.
ABSTRACT | FULL TEXT  

Correlation between central corneal thickness, applanation tonometry, and direct intracameral IOP readings
Feltgen et al.
Br. J. Ophthalmol. 2001;85:85-87.
ABSTRACT | FULL TEXT  

Central corneal thickness determined with optical coherence tomography in various types of glaucoma
Bechmann et al.
Br. J. Ophthalmol. 2000;84:1233-1237.
ABSTRACT | FULL TEXT  

The well tempered crystal ball in normal tension glaucoma
VERNON
Br. J. Ophthalmol. 1999;83:999-1000.
FULL TEXT  

Tonometry and Corneal Thickness
Brubaker
Arch Ophthalmol 1999;117:104-105.
FULL TEXT  





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 1999 American Medical Association. All Rights Reserved.