Three-dimensional Ultrasonography of Choroidal Melanoma
Localization of Radioactive Eye Plaques
Paul T. Finger, MD;
Juan M. Romero, MD;
Richard B. Rosen, MD;
Raymond Iezzi, MD;
Richard Emery, MS;
Anthony Berson, MD
Arch Ophthalmol. 1998;116:305-312.
Objective To evaluate the use of 3-dimensional (3D) ultrasonography for the localization of episcleral eye plaques during the treatment of choroidal melanomas.
Methods A series of 13 patients with choroidal melanoma were treated with radioactive palladium 103 seeds affixed into gold eye plaques. During surgery, 3D ultrasonography was performed with a commercially available system to evaluate the relative position of radioactive plaques secured beneath their intraocular tumors. This system consists of an automated, rotating, handheld, B-scan ultrasonographic probe operating at 10 MHz, a personal computer, and 3D imaging software.
Results We measured the margins of the plaque extending beyond the tumor and the distance between the radioactive seeds and the tumor apex. We also evaluated the relationship between the plaque edge, the episclera, and the tumor's edges. While the plaques were well centered over the tumor in all cases, the plaque margins around the tumor were found to be variably sized. When comparing measurements taken at the time of plaque insertion with those taken at the time of plaque removal, we noted changes in the apical tumor height and in plaque centration. In the 1 patient with a juxtapapillary tumor, the posterior margin of the plaque was found to be displaced away from the sclera, or "tilted."
Conclusions Three-dimensional ultrasonography offers a new method for ophthalmic plaque localization. Unique perspectives can be visualized through the use of computer-aided 3D reconstructions that permit the assessment of the relative position of the plaque to the optic nerve and the measurement of the distance between the in vivo radioactive seed and the tumor apex. Our experience suggests that when compared with 2-dimensional ultrasonography, 3D ultrasonography offers new capabilities that can be used to improve plaque placement and radiation dose calculations.
From the Ocular Tumor Service, the Department of Ophthalmology, the New York Eye and Ear Infirmary (Drs Finger, Romero, Rosen, and Iezzi), and the Department of Radiation Oncology, St Vincent's Medical Center (Drs Finger and Berson and Dr Emery), New York City. None of the authors has a proprietary interest in the equipment used for this study.
THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES
 |
Tilting of Radioactive Plaques After Initial Accurate Placement for Treatment of Uveal Melanoma
Almony et al.
Arch Ophthalmol 2008;126:65-70.
ABSTRACT
| FULL TEXT
Plaque Radiotherapy for Choroidal Melanoma Encircling the Optic Disc (Circumpapillary Choroidal Melanoma)
Sagoo et al.
Arch Ophthalmol 2007;125:1202-1209.
ABSTRACT
| FULL TEXT
Finger's "slotted" eye plaque for radiation therapy: treatment of juxtapapillary and circumpapillary intraocular tumours
Finger
Br. J. Ophthalmol. 2007;91:891-894.
ABSTRACT
| FULL TEXT
Sonography of the Eye
Bedi et al.
Am. J. Roentgenol. 2006;187:1061-1072.
ABSTRACT
| FULL TEXT
Laser photocoagulation for radiation retinopathy after ophthalmic plaque radiation therapy
Finger and Kurli
Br. J. Ophthalmol. 2005;89:730-738.
ABSTRACT
| FULL TEXT
Three dimensional ultrasound of retinoblastoma: initial experience
Finger et al.
Br. J. Ophthalmol. 2002;86:1136-1138.
ABSTRACT
| FULL TEXT
Three-Dimensional Ultrasound for the Measurement of Choroidal Melanomas
Romero et al.
Arch Ophthalmol 2001;119:1275-1282.
ABSTRACT
| FULL TEXT
Tumour location affects the incidence of cataract and retinopathy after ophthalmic plaque radiation therapy
Finger
Br. J. Ophthalmol. 2000;84:1068-1070.
ABSTRACT
| FULL TEXT
Usefulness of three dimensional ultrasonography for invisible fundus
ENDO et al.
Br. J. Ophthalmol. 2000;84:1075g-1075.
FULL TEXT
Plaque-Mounted Diode-Light Transillumination for Localization Around Intraocular Tumors
Finger et al.
Arch Ophthalmol 1999;117:179-183.
ABSTRACT
| FULL TEXT
|