You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 116 No. 10, October 1998 TABLE OF CONTENTS
  Archives
  •  Online Features
  Laboratory Sciences
 This Article
 •Full text
 •PDF
 • Reply to article
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on HighWire
 •Citing articles on Web of Science (35)
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Topic Collections
 •Ophthalmology, Other
 •Alert me on articles by topic
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati Add to Twitter What's this?

Accommodation Amplitude After Lens Refilling With Injectable Silicone by Sealing the Capsule With a Plug in Primates

Okihiro Nishi, MD; Kayo Nishi, MD

Arch Ophthalmol. 1998;116:1358-1361.

Objective  To restore accommodation in primate eyes by refilling the lens capsule with injectable silicone compounds.

Materials and Methods  Eight eyes of 8 monkeys (Macaca fascicularis) were treated by the lens refilling procedure. To prevent leakage of the injected liquid silicone before it polymerized in the capsule in vivo, a silicone plug for sealing the capsular opening was developed. After endocapsular phacoemulsification following an upper minicircular capsulorhexis, the plug was introduced into the capsulorhexis opening. A silicone mixture was injected into the capsular bag through the delivery tube of the plug. Automated refractometry was performed 1 week and 3 months after surgery. Accommodation amplitude was determined as the difference between the refractions before and 1 hour after topical application of 4% pilocarpine chloride.

Results  Five of 8 eyes could be refilled. In 4 of 5 eyes, refraction could be measured. Accommodation amplitude ranged from 1.0 to 4.5 diopters, with a mean of 2.3±1.3 diopters (8.0±2.0 preoperative values). At 3-month examination, thick posterior capsule opacification precluded refractometry in all eyes.

Conclusions  The lens refilling procedure with the use of a silicone plug for sealing the capsular opening was feasible in primate eyes. The accommodation amplitude attained was a small fraction of the value before surgery. This may result from the loss of so-called intracapsular accommodation, ie, active participation of lens fiber cells in accommodation. However, since the obtained accommodation may be sufficient for near vision after cataract surgery, this lens refilling procedure warrants further study. Elucidation of the mechanism of intracapsular accommodation may also be necessary.


From the Nishi Eye Hospital, Osaka, Japan.



Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter     What's this?

THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

Role of the Lens Capsule on the Mechanical Accommodative Response in a Lens Stretcher
Ziebarth et al.
IOVS 2008;49:4490-4496.
ABSTRACT | FULL TEXT  

Changes in Spherical Aberration after Lens Refilling with a Silicone Oil
Wong et al.
IOVS 2007;48:1261-1267.
ABSTRACT | FULL TEXT  

Accommodative lens refilling in rhesus monkeys.
Koopmans et al.
IOVS 2006;47:2976-2984.
ABSTRACT | FULL TEXT  

Potential of the 1 CU accommodative intraocular lens
Sauder et al.
Br J Ophthalmol 2005;89:1289-1292.
ABSTRACT | FULL TEXT  

In vitro and in vivo study of lens refilling with poloxamer hydrogel
Han et al.
Br J Ophthalmol 2003;87:1399-1402.
ABSTRACT | FULL TEXT  

Polymer Refilling of Presbyopic Human Lenses In Vitro Restores the Ability to Undergo Accommodative Changes
Koopmans et al.
IOVS 2003;44:250-257.
ABSTRACT | FULL TEXT  





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 1998 American Medical Association. All Rights Reserved.