You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 115 No. 9, September 1997 TABLE OF CONTENTS
  Archives
  •  Online Features
  ARTICLE
 This Article
 • Reply to article
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on HighWire
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal

Central corneal thickness in normal, glaucomatous, and ocular hypertensive eyes

L. W. Herndon, S. A. Choudhri, T. Cox, K. F. Damji, M. B. Shields and R. R. Allingham
Department of Ophthalmology, Duke University Medical Center, Durham, NC, USA.

OBJECTIVE: To determine the relationship between central corneal thickness (CCT) and applanation intraocular pressure (IOP) in normal, glaucomatous, and ocular hypertensive eyes. METHODS: One hundred nine subjects (184 eyes) were studied. Forty-eight patients (74 eyes) had glaucoma, 28 patients (51 eyes) had ocular hypertension, and 33 patients (59 eyes) were normal. Intraocular pressure as measured by applanation tonometry, refractive status, CCT, and axial length were measured for all subjects. RESULTS: The CCT (mean +/- SD) of eyes with ocular hypertension was significantly greater (0.606 +/- 0.041 mm) than that of glaucomatous eyes (0.554 +/- 0.022 mm) (P < .001) or of normal controls (0.561 +/- 0.026 mm) (P < .001). There was no significant difference in CCT between normal and glaucomatous eyes (P = .40). The axial length (mean +/- SD) of eyes with ocular hypertension (23.54 +/- 1.34 mm) was not different compared with glaucomatous eyes (23.93 +/- 0.96 mm) (P = .13) or normal eyes (23.62 +/- 1.21 mm) (P = .83). There was no significant difference between the axial length for glaucomatous eyes compared with normal eyes (P = .18). Those eyes with glaucoma being treated with topical dorzolamide hydrochloride had a significantly increased CCT (0.560 +/- 0.025 mm) compared with those eyes with glaucoma not being treated with dorzolamide (0.551 +/- 0.20 mm) (P = .02). CONCLUSIONS: The mean CCT is increased in eyes with ocular hypertension when compared with normal or glaucomatous eyes, which confirms the findings of other investigators. Increased CCT may give an artificially high IOP measurement by applanation tonometry. The CCT must be considered when developing a treatment approach for patients with ocular hypertension.

THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

Effect of Dorzolamide Hydrochloride on Central Corneal Thickness in Humans With Cornea Guttata
Wirtitsch et al.
Arch Ophthalmol 2007;125:1345-1350.
ABSTRACT | FULL TEXT  

Effect of Central Corneal Thickness on Dynamic Contour Tonometry and Goldmann Applanation Tonometry in Primary Open-angle Glaucoma
Grieshaber et al.
Arch Ophthalmol 2007;125:740-744.
ABSTRACT | FULL TEXT  

SNPs and Interaction Analyses of Noelin 2, Myocilin, and Optineurin Genes in Japanese Patients with Open-Angle Glaucoma
Funayama et al.
IOVS 2006;47:5368-5375.
ABSTRACT | FULL TEXT  

Ocular Response Analyzer versus Goldmann Applanation Tonometry for Intraocular Pressure Measurements.
Martinez-de-la-Casa et al.
IOVS 2006;47:4410-4414.
ABSTRACT | FULL TEXT  

Glaucoma and increased central corneal thickness in aphakic and pseudophakic patients after congenital cataract surgery
Simsek et al.
Br. J. Ophthalmol. 2006;90:1103-1106.
ABSTRACT | FULL TEXT  

Longitudinal changes in central corneal thickness and their relation to glaucoma status: an 8 year follow up study
Weizer et al.
Br. J. Ophthalmol. 2006;90:732-736.
ABSTRACT | FULL TEXT  

Circadian variations in central corneal thickness and intraocular pressure in patients with glaucoma
Fogagnolo et al.
Br. J. Ophthalmol. 2006;90:24-28.
ABSTRACT | FULL TEXT  

Underestimate of Tonometric Readings after Photorefractive Keratectomy Increases at Higher Intraocular Pressure Levels
Tamburrelli et al.
IOVS 2005;46:3208-3213.
ABSTRACT | FULL TEXT  

Central Corneal Thickness Correlated with Glaucoma Damage and Rate of Progression
Jonas et al.
IOVS 2005;46:1269-1274.
ABSTRACT | FULL TEXT  

Clinical Significance of Central Corneal Thickness in the Management of Glaucoma
Shih et al.
Arch Ophthalmol 2004;122:1270-1275.
ABSTRACT | FULL TEXT  

Clinical Comparison of the Proview Eye Pressure Monitor With the Goldmann Applanation Tonometer and the TonoPen
Li et al.
Arch Ophthalmol 2004;122:1117-1121.
ABSTRACT | FULL TEXT  

Effect of corneal parameters on measurements using the pulsatile ocular blood flow tonograph and Goldmann applanation tonometer
Gunvant et al.
Br. J. Ophthalmol. 2004;88:518-522.
ABSTRACT | FULL TEXT  

Tonometric Changes of Latanoprost-Induced Intraocular Pressure Reduction after Photorefractive Keratectomy
Tamburrelli et al.
IOVS 2004;45:846-850.
ABSTRACT | FULL TEXT  

Central Corneal Thickness as a Risk Factor for Advanced Glaucoma Damage
Herndon et al.
Arch Ophthalmol 2004;122:17-21.
ABSTRACT | FULL TEXT  

Central Corneal Thickness in Latinos
Hahn et al.
IOVS 2003;44:1508-1512.
ABSTRACT | FULL TEXT  

Corneal Thickness and Intraocular Pressure in the Barbados Eye Studies
Nemesure et al.
Arch Ophthalmol 2003;121:240-244.
ABSTRACT | FULL TEXT  

Using the Arteriolar Pressure Attenuation Index to Predict Ocular Hypertension Progression to Open-angle Glaucoma
Cohen et al.
Arch Ophthalmol 2003;121:33-38.
ABSTRACT | FULL TEXT  

A few remarks about glaucoma
Wegner
Br. J. Ophthalmol. 2002;86:836-837.
FULL TEXT  

The Ocular Hypertension Treatment Study: Baseline Factors That Predict the Onset of Primary Open-Angle Glaucoma
Gordon et al.
Arch Ophthalmol 2002;120:714-720.
ABSTRACT | FULL TEXT  

Central corneal thickness measurements in patients with normal tension glaucoma, primary open angle glaucoma, pseudoexfoliation glaucoma, or ocular hypertension
Ventura et al.
Br. J. Ophthalmol. 2001;85:792-795.
ABSTRACT | FULL TEXT  

Increased Corneal Thickness in Patients With Ocular Hypertension
Herman et al.
Arch Ophthalmol 2001;119:334-336.
ABSTRACT | FULL TEXT  

Correlation between central corneal thickness, applanation tonometry, and direct intracameral IOP readings
Feltgen et al.
Br. J. Ophthalmol. 2001;85:85-87.
ABSTRACT | FULL TEXT  

Central corneal thickness determined with optical coherence tomography in various types of glaucoma
Bechmann et al.
Br. J. Ophthalmol. 2000;84:1233-1237.
ABSTRACT | FULL TEXT  

Evaluation of corneal thickness and topography in normal eyes using the Orbscan corneal topography system
Liu et al.
Br. J. Ophthalmol. 1999;83:774-778.
ABSTRACT | FULL TEXT  

Tonometry and Corneal Thickness
Brubaker
Arch Ophthalmol 1999;117:104-105.
FULL TEXT  

Central Corneal Thickness
Hustead and Herndon
Arch Ophthalmol 1998;116:1263-1263.
FULL TEXT  

Corneal Thickness and Applanation Pressure
Naumann and Herndon, Jr
Arch Ophthalmol 1998;116:701-701.
FULL TEXT  

Corneal Pachymetry: A Prerequisite for Applanation Tonometry?
Tanaka
Arch Ophthalmol 1998;116:544-545.
FULL TEXT  





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 1997 American Medical Association. All Rights Reserved.