You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 107 No. 11, November 1989 TABLE OF CONTENTS
  Archives
  •  Online Features
  CLINICAL SCIENCES
 This Article
 •References
 •Full text PDF
 • Reply to article
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on HighWire
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit Add to Technorati Add to Twitter What's this?

Response Properties of Normal Observers and Patients During Automated Perimetry

Jacqueline M. Nelson-Quigg; J. Daniel Twelker; Chris A. Johnson, PhD

Arch Ophthalmol. 1989;107(11):1612-1615.


Abstract

• Automated perimetry was performed on both eyes of 54 normal subjects, 36 patients with ocular hypertension and normal visual fields, and 20 patients with early glaucomatous visual field loss to evaluate false-positive errors, false-negative errors, fixation losses, consistency of double determinations, and testing time. For all subject groups and response measures, large interindividual variation was found. No meaningful age-related changes were obtained for false-negative errors, false-positive errors, fixation losses, or consistency of double determinations. Contrary to earlier reports, we found a low number of normal subjects and patients exceeding the 33% false-positive and false-negative limits established for the Humphrey Field Analyzer. A large number of normal subjects and patients, however, exceeded the 20% limits for fixation losses.



Author Affiliations

From the Department of Ophthalmology, University of California, Davis (Ms Nelson-Quigg, Mr Twelker, and Dr Johnson), and the School of Optometry, University of California, Berkeley (Mr Twelker).


Footnotes

Accepted for publication July 14, 1989.

Reprint requests to Department of Ophthalmology, University of California, Davis, Davis, CA 95616 (Dr Johnson).



Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter     What's this?

THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

Effect of a patient training video on visual field test reliability
Sherafat et al.
Br J Ophthalmol 2003;87:153-156.
ABSTRACT | FULL TEXT  

Comparison of Analytic Algorithms for Detecting Glaucomatous Visual Field Loss
Katz et al.
Arch Ophthalmol 1991;109:1684-1689.
ABSTRACT  

Reliability of Automated Perimetric Tests-Reply
Johnson and Nelson-Quigg
Arch Ophthalmol 1990;108:778-778.
ABSTRACT  

Reliability of Automated Perimetric Tests
Katz and Sommer
Arch Ophthalmol 1990;108:777-778.
ABSTRACT  





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 1989 American Medical Association. All Rights Reserved.