You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


Advertisement

ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | RSS | Access Rights | Sign In


  Vol. 106 No. 6, June 1988 TABLE OF CONTENTS
  Online Only
 •  Online First Table of
Contents
  CLINICAL SCIENCES
 •Online Features
 This Article
 •References
 •Full text PDF
 • Reply to article
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on HighWire
 •Citing articles on Web of Science (79)
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Social Bookmarking
  Add to CiteULike Add to Connotea Add to Delicious Add to Digg Add to Facebook Add to Reddit Add to Technorati Add to Twitter What's this?

Comparison of the Tono-Pen to the Goldmann Applanation Tonometer

Ronald E. P. Frenkel, MD; Young J. Hong, MD; Dong H. Shin, MD, PhD

Arch Ophthalmol. 1988;106(6):750-753.


Abstract



• Oculab Tono-Pen tonometry was compared with Goldmann applanation tonometry in 142 eyes of 71 patients without corneal problems. Overall we found 63% of the Tono-Pen readings to be within ±2 mm Hg of the Goldmann applanation tonometry readings and 77% to be within ±3 mm Hg, while 4% were within at least ±7 mm Hg difference. The correlation coefficient between the readings of the two instruments was.84. The mean value of the paired differences was 0.81 ± 3.09 mm Hg overall, –1.78 ± 1.86 mm Hg in the 4 to 10 mm Hg interval, 0.07 ± 2.97 mm Hg in the 11 to 20 mm Hg interval, 1.27 ± 2.62 mm Hg in the 21 to 30 mm Hg interval, and 4.15 ± 2.28 mm Hg in the 31 to 45 mm Hg interval. We conclude that the Tono-Pen measures intraocular pressure in a manner that corresponds well to the Goldmann tonometer in the 11 to 20 mm Hg interval, and fairly well in the 4 to 10 mm Hg and 21 to 30 mm Hg intervals. It lacks good correspondence in the 31 to 45 mm Hg interval.



Author Affiliations



From the Kresge Eye Institute, Wayne State University School of Medicine, Detroit. Dr Frenkel is now with the Massachusetts Eye and Ear Infirmary, Harvard Medical School, Boston.


Footnotes



Accepted for publication Dec 25, 1987.

Reprint requests to the Kresge Eye Institute, 3994 John R, Detroit, MI 48201 (Dr Shin).



Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Delicious Delicious   Add to Digg Digg   Add to Facebook Facebook   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter     What's this?

THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

Effects of an intravenous bolus of alfaxalone versus propofol on intraocular pressure in sheep
Torres et al.
The Veterinary Record 2012;0:vr.100399v1-vetrec-2011-100399.
ABSTRACT | FULL TEXT  

Corneal Modulus and IOP Measurements in Canine Eyes Using Goldmann Applanation Tonometry and Tono-pen
Tang et al.
IOVS 2011;52:7866-7871.
ABSTRACT | FULL TEXT  

Reproducibility and Clinical Evaluation of Rebound Tonometry
Martinez-de-la-Casa et al.
IOVS 2005;46:4578-4580.
ABSTRACT | FULL TEXT  

A comparison of four methods of tonometry: method agreement and interobserver variability
Tonnu et al.
Br J Ophthalmol 2005;89:847-850.
ABSTRACT | FULL TEXT  

Pressure Phosphene Self-Tonometry: A Comparison with Goldmann Tonometry in Glaucoma Patients
Lam et al.
IOVS 2004;45:3131-3136.
ABSTRACT | FULL TEXT  

Dynamic Contour Tonometry: A Comparative Study on Human Cadaver Eyes
Kniestedt et al.
Arch Ophthalmol 2004;122:1287-1293.
ABSTRACT | FULL TEXT  

Clinical Comparison of the Proview Eye Pressure Monitor With the Goldmann Applanation Tonometer and the TonoPen
Li et al.
Arch Ophthalmol 2004;122:1117-1121.
ABSTRACT | FULL TEXT  

Effect of Corneal Thickness on Intraocular Pressure Measurements with the Pneumotonometer, Goldmann Applanation Tonometer, and Tono-Pen
Bhan et al.
IOVS 2002;43:1389-1392.
ABSTRACT | FULL TEXT  

Tono-Pen determination of intraocular pressure in patients with band keratopathy or glued cornea
Azuara-Blanco et al.
Br J Ophthalmol 1998;82:634-636.
ABSTRACT | FULL TEXT  

Measurement of intraocular pressure after epikeratophakia
Wright and Grajewski
Br J Ophthalmol 1997;81:448-451.
ABSTRACT | FULL TEXT  





HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | PHYSICIAN JOBS | SUBMIT | SUBSCRIBE | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 1988 American Medical Association. All Rights Reserved.