Immunoreactive opsin content in subretinal fluid from patients with rhegmatogenous retinal detachments
S. Hara, S. Ishiguro, S. Hayasaka and K. Mizuno
We determined the immunoreactive opsin content in the subretinal fluid from
16 patients with rhegmatogenous retinal detachment by enzyme-linked
immunosorbent assay. The opsin content decreased, with the duration of the
detachment, but there was no correlation between opsin content and the age
of the patient or the extent of the retinal detachment.